- Place of Origin:
- Guangdong, China
- Brand Name:
- ASENWARE
- Model Number:
- AW-BK901
- Alarm type::
- Beam Smoke Detector
- Certificates::
- CE Rohs ISO9001
- Operating Voltage::
- DC16V~DC32V
- Adjusting Angle::
- -6 DEG ~+6 DEG
- Design:
- OEM/ODM
- External Dimensions::
- 206mm*95mm*95 mm
- Light path Length::
- 8m~100m
- Alarm current::
- ≤22mA
- Housing Materials::
- ABS, White shell
- Operating Environment::
- Warehouses, large-scale storage ares,shopping plazas
- Supply Ability:
- 100000 Piece/Pieces per Month
- Packaging Details
- PP Bag &Sponge inside,carton outside
- Port
- Shenzhen
Fire alarm beam detector brief introduction:
AW-BK901 Infrared Beam Smoke Detector (hereinafter referred to as detector) is a long-interval reflection line infrared beam smoke detector which must be used together with a reflector.
Fire alarm beam detector working principle:
In case of smoke on the light path of the detector, the signal arriving at the receiver is reduced; when the light reduction rate reaches the preset threshold, the detector will produce the alarm signal; when the light beam is completely blocked, the detector will produce the fault signal to prevent the false alarm caused by non-fire blockage.
Fire alarm beam detector application Places:
Warehouses, large-scale storage areas, shopping plazas, body-building centers, gymnasiums, exhibition halls, hotel halls, printing works, costume plants, museums, prisons, etc, as well as space with light smoke dust
Fire alarm beam detector picture:
Fire alarm beam detector characters:
1. Has a built-in uniprocessor with excellent performance;
2. Wide operating voltage range and wide protective area
3. Self-diagnosis capability, monitoring of faults in the detector
4. Field setup of two levels of sensitivity
5. Built-in microprocessor, intelligentized fire alarm and fault judgment
6. Fire alarm and fault passive output contacts and standard 4-20mA standard power supply output
7. Smart design of the detection light path, high antijamming performance, seal protocol, corrosion protection and waterproof performance
8. Integration of the transmitting part and the receiving part, simple and convenient installation, good light path collimation
9. Automatic compensation function, and automatic compensation for factors of received signal reduction such as dust pollution, position deflection, ageing of the transmitting tube, etc. to some extent
10. Automatic calibration function to enable a single person to complete debug within a short time, simple operation, easy integration of the transmitting part and the receiving part, simple and convenient installation, good light path collimation
Fire alarm beam smoke detector parameters:
Operating Voltage | DC16V~DC32V |
Adjusting Angle | -6 DEG ~+6 DEG |
External Dimensions | 206mm×95mm×95 mm (length×width×thickness) |
Material and Color of the Casing | ABS, white |
Weight | 450g |
Light path Length | 8m~100m |
Operating Current | monitoring current ≤12 mA, alarm current ≤22mA, debugging current ≤20mA |
Indication of status of the detector | 1) Debugging Status: the green, red and yellow indicator lamps light up or flash in a specific mode. 2) Normal monitoring status: the green indicator lamp flashes periodically. 3) Fire Alarm: the red indicator lamp keeps lighting;the yellow indicator lamp blacks out. The fire alarm should be cancelled through being powered again. 4) Fault: the yellow indicator lamp keeps lighting; in case of fault recovery, the fault signal of the detector is automatically cancelled by the detector. 5) If the light path is completely blocked, the detector reports a fault and the yellow indicator lamp lights up. |
Operating Environment | temperature -10°C~+50°C relative humidity ≤95% without condensation |
Protective Area | the maximal protective area of the detector 14×100=1400 m2 |