- Place of Origin:
- Guangdong, China
- Brand Name:
- Asenware
- Model Number:
- AW-CFP2166-8
- color:
- red
- Weight:
- 7kg
- Operating voltage:
- 24V (pulse modulation)
- Matched host machine:
- fire alarm control panel
- Certificates:
- CE Rohs ISO9001
- Product Name:
- GSM 8 zone conventional fire alarm control panel
- nature:
- conventional
- Wiring Method:
- 2 bus system fire alarm system
- Design:
- OEM ODM
- Executive standard:
- GB19880-250
- Supply Ability:
- 100000 Set/Sets per Year
- Packaging Details
- Export Standard Packing
- Port
- Shenzhen
Fire Alarm Smoke Detector Proposal for building,hotel,apartment,hospital,warehouse,etc.
Asenware,your fire alarm & fire-fighting solution professional provider.
Model | AW-CFP2166 1 to 32zones |
Mains Voltage | 110VAC or 240VAC |
Internal power supply | 27.2VDC |
Batteries | 12V2AH*2 |
Zone Capacity | 20pcs detector |
Sounder outputs | 500mA F 20mm |
Battery fuse | 1.5A F 20mm |
8 zone conventional fire alarm control panel GSM wire drawing detailed show
1.AW-CFP21668 zone conventional fire alarm panel wire drawing is FYI .
Fire alarm control panels are designed to fulfil the requirements of EN54 parts 2 & 4 as well as being easy to install, operate and maintain. Being of modular construction,
2.The basic fire panel has 1 zone capacity, expandable to 2,4,8,10,12,14,16, 20 , 24 ,28,30 and 32 zones. The Premier M Plus is suitable for surface mounting or semi-flush fitting (with just the door protruding.
The detail picture conventional fire alarm alarm detailed show
Conventional system 8-zone fire alarm control panel operate parameters
End of Line device | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) |
Detector continuity diodes | Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault) |
Call point resistor value | 470 to 680 Ω, 0.225 or 0.5 watt |
Maximum number of smoke/heat detectors per zone | 20 (based on a total detector current of 2mA, each detector consuming 100μ A).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts. |
Maximum number of manual call points per zone | No limit |
Line fault monitor for detector | Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor |
Line fault monitor for open circuit | Yes |
Line fault monitor for short circuit | Yes |
Packaging & Shipping
Fire alarm panel packaging and shipping detail
Packaging : Use carton to pack 8 zone fire alarm control panel well .
Shpping :UPS FEDEX EMS DHL negotiable for shpping fire alarm control panel
Our Services
Our services
1.OEM ODM can be provided .
2.Technical support like how to install operate .Any question will be answer within 24 hours .
3.We have prfessional technical team to help customers solve technical problems .
4.Hotel project hospital factory fire alarm system project can be made .
Company Information
1.Asenware was set up in 2006, and is a technology oriented company that devotes to NDT (Non Destructive Test) and BAC (Building Automatic Control) industries
2. We have an experienced R&D team to design special testing items or automatic control products
3. We have two factories: one factory is in Shenzhen for BMS products, and the other one is in Dandong for NDT X-ray products
FAQ
Fire alarm control panel FAQ
Payment terms :T/T L/C Western union .
Delievry time :usually about 2 to 5 days .Mass product about three weeks .
Warranty :one year
Certificate :CE LPCB ISO9001
Technical support :yes
Online Messenger in real time response to your inquiry through below contacts: