Home > Products > 4 Zone conventional fire alarm panel
4 Zone conventional fire alarm panel
Click on the image to view the original image
Product: views:264 Zone conventional fire alarm panel 
Branch: ASENWARE
Unit Price: Negotiated
Min.Order:
Supply:
Delivery: Shipment within days since the date of payment
Valid until: Long Term
Updated on: 2019-10-17 03:21
  Negotiated
Product Details
Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
ASENWARE
Model Number:
AW-CFP2166-4
Zone number:
4
Supply Ability
Supply Ability:
10000 Set/Sets per Year
Packaging & Delivery
Packaging Details
carton
Port
Shenzhen

Introduction:

 

  1. AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
  2. It is modularized design, the panel can expend from 1 zone to 16 zones easily.
  3. It has 2 level control mode by a lock
  4. It has TEST/ALARM OUTPUT function, when TEST is enable, the user can test all buttons and won’t let the sounders be active.
  5. It has SOUNDERS OUTPUT option, if one zone is fire alarm, all other zones sounders can be active or not.
  6. It has 27VDC power supply output.
  7. It has FIRE signal output.
  8. It has 2 general sounders output, any zone fire alarm will let the 2 general sounders be active.
  9. Each zone has 1 circuit detectors input and 2 SOUNDERs output.
  10. Each zone can test zone fault, sounder fault and show on the front panel.
  11. It has RESET button to reset the panel.
  12. It has SILENCE button to stop BUZZER and SOUNDERS.
  13. It has EVACUATE button to start a manual fire alarm immediately.
  14. It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
  15. It uses plug-in sockets and plugs, convenience for maintenance.
  16. It is economic, user-friendly and easy maintenance.

 

Parameters:

ITEM

4 Zone panel

8 Zone panel

16 Zone panel

Model No.

AW-CFP2166-04

AW-CFP2166-08

AW-CFP2166-16

Power specification

Mains supply voltage

100-240VAC

Internal power supply

27.2VDC

Total output current limited

1.6A @ 240VAC

3A @ 240VAC

5A @ 240VAC

Main supply monitor for fault

Yes

Battery protection for low voltage

Yes

Batteries (default configuration)

12V2AH*2

12V3.2AH*2

12V7AH*2

Detector circuit specification

Number of circuit

1-4

1-8

1-16

Line fault monitor for open circuit

Yes

Line fault monitor for short circuit

Yes

Line fault monitor for detector removal

Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor

End of Line device

6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)

Detector continuity diodes

Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)

Call point resistor value

470 to 680 Ω, 0.225 or 0.5 watt

Maximum number of smoke/heat detectors per zone

20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.

Maximum number of manual call points per zone

No limit

Sounder circuit specification

Number of general circuits

2

Number of each zone

2

End of line resistor value

6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)

Line fault monitor for open circuit

Yes

Line fault monitor for short circuit

Yes

Outputs fused AT

400mA

Maximum number of bells @ 25mA of each zone

16(These quantities are examples only. Divide 400 by the consumption of each sounder/bell in mA to calculate the maximum number.)

Maximum number of bells @ 20mA of each zone

20

Fuses

Battery fuse

1.5A F 20mm

3A F 20mm

5A F 20mm

Sounder outputs

500mA F 20mm

 

 

Fire output

Output type

Intended to drive external 24V relays

Maximum current

30mA(Relay resistance must be greater than 800Ω and relay must have “ back EMF” diode fitted).

Connection block

Largest acceptable conductor size

2.5mm2

Smallest acceptable conductor size

0.75mm2

Size and weight

Dimensions(mm)

395X388X124

395X502X124

362X565X124

Weight (without batteries)

5kg

7kg

8kg

Weight (with batteries)

6.8kg

9.6kg

12.5kg