Home > Products > SASO Approval Four wire 12V relay output wired smoke detector
SASO Approval Four wire 12V relay output wired smoke detector
Click on the image to view the original image
Product: views:5SASO Approval Four wire 12V relay output wired smoke detector 
Branch: ASENWARE
Unit Price: Negotiated
Min.Order:
Supply:
Delivery: Shipment within days since the date of payment
Valid until: Long Term
Updated on: 2019-10-16 15:25
  Negotiated
Product Details
Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
ASENWARE
Model Number:
AW-CSD811
Item:
Four wire 12V relay output wired smoke detector
Operating Voltage Range:
9 to 28 VDC Volts Non-polarized
Standby Current:
≤120μ A@24VDC
Maximum Alarm Current (LED on):
≤15mA@24VDC
Operating Humidity Range:
≤95%RH(40°C±2°C)
Relative Humidity:
Non-condensing
Operating Temperature Range:
-10° C to 50° C (14° F to 122° F)
Smoke Alarm Sensitivity:
1.06± .26%FT
Fix temperature Alarm:
57° C (135° F) A1R
Diameter:
99.45 mm
Supply Ability
Supply Ability:
50000 Piece/Pieces per Month
Packaging & Delivery
Packaging Details
with foam bag and export catton
Port
Zhongshan
Lead Time:
Quantity(Pieces)1 - 1000 >1000
Est. Time(days)7To be negotiated

Four wire 12V relay output wired smoke detector

Product Description

 

The detectors are photo-electronic detector uses a state of-the-artoptical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel. Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption. The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel. Heat detector and smoke & heat detector combine a photo electronic sensing chamber and a temperature heat detector

 

Parameter

 

Operating Voltage Range9 to 28 VDC Volts Non-polarized
Standby Current≤120μ A@24VDC
Maximum Alarm Current (LED on):≤15mA@24VDC
Operating Humidity Range≤95%RH(40°C±2°C
Relative HumidityNon-condensing
Operating Temperature Range-10° C to 50° C (14° F to 122° F)
Smoke Alarm Sensitivity1.06± .26%FT
Fix temperature Alarm57° C (135° F) A1R
Rate of rise Alarm7.1° C/5S A1R
Height48.2 mm installed in Base
Diameter99.45 mm

 

 

Detailed Images

 

 

 

 

Company Information

 

 

Our Services

 

1)Sample oder is welcomed to test the quality.

2 ) Flexible technicals adjusting as per customer" s special request.

3) Answer your enquiries, questions and emails in 24 hours

4) Direct control on material, testing, quality, leadtime etc.

 

Packaging & Shipping

 

1.Ship by express,by air,by sea and son on.

2.Packed with foam bag and export caron

3.Lead time:3-5 days

 

FAQ

 

 

询价单
total0items  Comments