- Place of Origin:
- Guangdong, China
- Brand Name:
- Asenware
- Model Number:
- AW-CFP2166-08
- Mains supply voltage:
- 110VAC or 220VAC
- Internal power supply:
- 27.2VDC
- Number of circuit:
- 4
- Outputs fused AT:
- 600mA
- Battery fuse:
- 1.85A resettable fuse
- Sounder outputs:
- 1.85A resettable fuse
- Output type:
- and NO relay
- Maximum current:
- 100mA
- Supply Ability:
- 10000 Unit/Units per Month
- Packaging Details
- Carton
- Port
- Shenzhen
Asenware 8 Zones Control Panel Fire Alarm System
Introduction:
The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.
1. AW-CFP2166 series conventional fire alarm panel is designed based on
EN54 part 2&4 standard.
2. It is modularized design, the panel can expand from 1 zone to 32
zones easily.
3. It has 2 level control mode by a lock.
4. It has 24VDC power supply output.
5. It has FIRE and FAULT signal output.
6. It has 2 general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. It has SILENCE button to stop BUZZER and SOUNDERS.
11. It has EVACUATE button to start a manual fire alarm immediately.
12. It has an optional GSM module for fire alarm by SMS.
13. It is economic, user-friendly and easy maintenance.
Mains supply voltage | 110VAC or 220VAC |
Internal power supply | 27.2VDC |
Total output current limited | 3A @ 220VAC |
Batteries (default configuration) | 12V2.3AH*2 |
Number of circuit | 4 |
End of Line device | 6.8k Ω,5% tolerance, 0.5-1W (colour code-blue,grey,red,gold) |
Call point resistor value | 470 to 680 Ω, 0.5 or 1 watt |
Number of general circuits | 2 |
Outputs fused AT | 600mA |
Maximum number of bells @ 50mA of each Sounder output | 12 |
Battery fuse | 1.85A resettable fuse |
Sounder outputs | 600mA resettable fuse |
Output type | NC and NO relay |
Maximum current | 100mA |
Largest acceptable conductor size | 2.5mm2 |
Smallest acceptable conductor size | 0.75mm2 |
Our company
Asenware, manufacturer of fire alarm and fire suppression system since 2005. Our headquarter is in London, UK, with factory Shenzhen, China
We keep our best service for our customers, and have a rich experienced engineer team to design and install for overseas projects.
Product range:
1. Addressable fire alarm system(FP100 series,2189,2100 series)
2. Conventional fire alarm system(2166 series)
3. FM200 gas fire suppression system
4. Emergency light system
5. Fire pump system
6. Fire hose and fire hose reel cabinet