Homepage|Business Center|Save the Page|Get the App
普通会员

Shenzhen Asenware Test & Control Technology Co., Ltd.

Product Category
  • No Category Yet
Search
 
Link
  • No links
Home > Products > Easy installation 4 zone conventional fire alarm system with CE
Easy installation 4 zone conventional fire alarm system with CE
Click on the image to view the original image
Product: views:3Easy installation 4 zone conventional fire alarm system with CE 
Branch: ASENWARE
Size: 70X20X45 cm
Unit Price: Negotiated
Min.Order:
Supply:
Delivery: Shipment within days since the date of payment
Valid until: Long Term
Updated on: 2019-11-19 18:28
  Negotiated
Product Details
Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
ASENWARE
Model Number:
AW-CFP2166-4
Product name:
Conventional Fire Alarm Control Panel
Voltage:
110VAC or 240VAC
Output Current:
3A@240VAC
Usage:
Fire Alarm Display
Zone:
4 Zones
Nature:
Convcentional
Max detector per zone:
20 pcs
warranty:
2 years
Battery:
12V2AH*2
Certificate:
CE.ISO9001

Packaging & Delivery

Selling Units:
Single item
Single package size: 
70X20X45 cm
Single gross weight:
14.0 kg
Package Type:
Standard carton
Lead Time:
Quantity(Piece)1 - 10000>10000
Est. Time(days)10To be negotiated
Product Description

   AW-CFP 2166 Conventinal fire alarm panel 1 to 32 zone.

1 AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.

2 It is modularized design, the panel can expend from 1 zone to 32 zones easily.

3 It has 2 level control mode by a lock

4 It has 24VDC and 5VDC power supply output.

5 It has FIRE and FAULT signal output.

6 It has 2 general sounders output.

7 Each zone has 1 circuit detectors input .

8 Each zone can be disable by a button.

9 It has RESET button to reset the panel.

10 It has SILENCE button to stop BUZZER and SOUNDERS.

11 It has EVACUATE button to start a manual fire alarm immediately.

12 It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.

13 It has an optional GSM module for fire alarm by SMS .

  

Parameters

 

ITEM

1 Zone panel

2 Zone panel

4-8 Zone panel

12-32 Zone panel

Model No.

AW-CFP2166-01

AW-CFP2166-02

AW-CFP2166-04-8

AW-CFP2166-12-32

Power specification

 

Mains supply voltage

110VAC or 240VAC

Internal power supply

27.2VDC

Total output current limited

500mA @ 240VAC

500mA @ 240VAC

3A @ 240VAC

3A @ 240VAC

Main supply monitor for fault

Yes

Battery protection for low voltage

Yes

Batteries (default configuration)

12V2AH*2

Detector circuit specification

 

Number of circuit

1

2

4-16

4-32

Line fault monitor for open circuit

Yes

Line fault monitor for short circuit

Yes

Line fault monitor for detector removal

Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor

End of Line device

6.8k Ω,5% tolerance, 0.25W (colour code-blue, grey, red, gold)

Detector continuity diodes

Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)

Call point resistor value

470 to 680 Ω, 0.225 or 0.5 watt

Maximum number of smoke/heat detectors per zone

20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maximum voltage drop must not exceed 12 volts.

Maximum number of manual call points per zone

No limit

Sounder circuit specification

 

Number of general circuits

2

End of line resistor value

6.8k Ω,5% tolerance, 0.25W (colour code-blue, grey, red, gold)

Line fault monitor for open circuit

Yes

Line fault monitor for short circuit

Yes

Outputs fused AT

400mA

Maximum number of bells @ 20mA of each sounder output

20

 

Picture:


 

Packaging & Shipping

 

Our Services

 

1. OEM/ODM services.

2. Quality assuance and rliabilty

3. Professional and experienced R&D center can offer free technical support. 

4. One year warranty and technical mainten

Company Information

 Asenware specialized in the Fire Alarm and BMS(Building Management System) over 10 years.
Professional and experienced R&D center provide complete fire alarm projects solutions and provide free technical support.
 
We have 5 series products: 
1. FP100 series: addressable fire alarm and control system 1oop to 8 loops.
2. 2189 and 2100 series: addressable fire alarm system
3. 2166 series: conventional fire alarm system, we have 1-32 zone panel. 
4. 2159 series: automatic fire extinguishing controllerm, Fm 200 fire suppression system.
5. Fire pump set, Fire hose & hose reel cabinet.
6. Emergency lighting system, twin spot emergency lights, exit sign.

 

 

 

 

 

FAQ

Q1. How about the quality of the products?

A: We produce every product with good quality materials, and test carefully to make sure stable quality before shipment.

Q2. Can I have a sample order?

A:Yes, Of course you can . we welcome sample order for your testing and checking products quality. Mixed samples are avaliable.

Q3. How do you ship the goods and how long does it take to arrive?

A: We usually ship by DHL, UPS, FedEx or TNT. Small Qty order needs 3-5 working days, big Qty order usually needs 10-15 working days after payments arriving. That"s depends on order Qty.

Q4. How to proceed an order ?

A: Firstly let us know your requirements or application.
Secondly We quote according to your requirements or our suggestions.
Thirdly customer confirms the samples and places deposit for formal order.
Fourthly We arrange the production.

Q5. How to proceed the order if I have logo to print?

A: We will prepare artwork for visual confirmation at first, if the color and position are alright, we will make print Logo sample from silk print factory and take picture for you to comfire before mass production.

 

 

询价单
total0items  Comments