Home > Products > 32 zone wired conventional fire alarm control panel with back up battery
32 zone wired conventional fire alarm control panel with back up battery
Click on the image to view the original image
Product: views:232 zone wired conventional fire alarm control panel with back up battery 
Branch: Asenware
Unit Price: Negotiated
Min.Order:
Supply:
Delivery: Shipment within days since the date of payment
Valid until: Long Term
Updated on: 2019-11-19 18:29
  Negotiated
Product Details
Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
Asenware
Model Number:
AW-CFP2166-32
Product name:
32zone Fire alarm control panel
Mains Supply Voltage:
110VAC or 240VAC
Output Current:
3A@240VAC
Battery:
12V2AH*2
FaultOutput:
NC and NO Relay
Wiring Structure:
2-bus Wiring System
Certificate:
INTERTEK CE, SASO, ISO9001,EN 54 standard
Max detector:
20pcs
GSM module:
fire alarm by SMS
warranty:
2year
Supply Ability
Supply Ability:
3000 Piece/Pieces per Month
Packaging & Delivery
Packaging Details
standard carton
Port
Shenzhen or Hongkong

16 zone conventional fire alarm panel (1-32 zone optional)

Intertek SASO and CE certificate

GSM module optional for fire alarm by SMS

Product Description

   AW-CFP 2166 Conventinal fire alarm panel 1 to 32 zone.

1 AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.

2 It is modularized design, the panel can expend from 1 zone to 32 zones easily.

3 It has 2 level control mode by a lock

4 It has 24VDC and 5VDC power supply output.

5 It has FIRE and FAULT signal output.

6 It has 2 general sounders output.

7 Each zone has 1 circuit detectors input .

8 Each zone can be disable by a button.

9 It has RESET button to reset the panel.

10 It has SILENCE button to stop BUZZER and SOUNDERS.

11 It has EVACUATE button to start a manual fire alarm immediately.

12 It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.

13 It has an optional GSM module for fire alarm by SMS .

  

Parameters

 

ITEM

1 Zone panel

2 Zone panel

4-8 Zone panel

12-32 Zone panel

Model No.

AW-CFP2166-01

AW-CFP2166-02

AW-CFP2166-04-8

AW-CFP2166-12-32

Power specification

 

Mains supply voltage

110VAC or 240VAC

Internal power supply

27.2VDC

Total output current limited

500mA @ 240VAC

500mA @ 240VAC

3A @ 240VAC

3A @ 240VAC

Main supply monitor for fault

Yes

Battery protection for low voltage

Yes

Batteries (default configuration)

12V2AH*2

Detector circuit specification

 

Number of circuit

1

2

4-16

4-32

Line fault monitor for open circuit

Yes

Line fault monitor for short circuit

Yes

Line fault monitor for detector removal

Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor

End of Line device

6.8k Ω,5% tolerance, 0.25W (colour code-blue, grey, red, gold)

Detector continuity diodes

Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)

Call point resistor value

470 to 680 Ω, 0.225 or 0.5 watt

Maximum number of smoke/heat detectors per zone

20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maximum voltage drop must not exceed 12 volts.

Maximum number of manual call points per zone

No limit

Sounder circuit specification

 

Number of general circuits

2

End of line resistor value

6.8k Ω,5% tolerance, 0.25W (colour code-blue, grey, red, gold)

Line fault monitor for open circuit

Yes

Line fault monitor for short circuit

Yes

Outputs fused AT

400mA

Maximum number of bells @ 20mA of each sounder output

20

 

Picture:


 

 

Company Information

Asenware specialized in the Fire Alarm and BMS(Building Management System) 12 years.

 

Professional and experienced R&D center provide complete fire alarm projects solutions and provide free technical support.

 

We have 6 series products:
1. 2100 series: addressable fire alarm and control system for big project, minimum address are 648,648*2,648*n.
2. 2188 series: addressable fire alarm system for small project, 1 loop, 324 addresses.
3. 2166 series: conventional fire alarm system, 1-32 zone.
4. 2159 series: automatic fire extinguishing controller, Fm 200 fire suppression system.

5. Fire pump set, Fire hose & hose reel cabinet.
6. Emergency lighting system, twin spot emergency lights, exit sign.

 Certificate:

 

Packaging & Shipping

  

 

 

Why choose us

 * Our products are economic, user-friendly and easy maintenance. 

* Prompt response.

* Standard quality control system.

* Independent R&D dept, designing dept,to meet your special need.

* Whole set of technical supports and with abroad projects experience.

* We are manufacturer, offer better price better production control.

* Reliable after-sales service, with one year warranty.

 

Our Services
 1. OEM/ODM services. 

2. Quality assuance and rliabilty

3. Professional and experienced R&D center can offer free technical support. 

4. One year warranty and technical maintenance.

 

FAQ

 

1. Packaging Details: EPE inside, carton outside

2. Shipping:delivered by air,ship or express for your order.

3. Delivery Time: 3-5 days after payment received

 

Contact us:

Name: Bella Yu     Skype: sales10_303

Whatsapp/ Wechat: 0086 13590136259

Ali ID:cn1512961300

Email: sales10 at asenware.com

 16 zone alarm control panel,16 zone conventional fire alarm control panel,fire alarm system control panel,wired alarm control panel,fire alarm panel conventional,fire alarm panel conventional

询价单
total0items  Comments