- Place of Origin:
- Shanghai, China
- Brand Name:
- SHCET
- Model Number:
- DZ30LE-CT2
- Type:
- Residual Current
- Poles Number:
- 1P 2P 3P 4P
- Product name:
- rccb residual current circuit breaker
- Poles available:
- 1P,2P,3P, 4P,1P+N,3P+N
- Rated current:
- 6A to 100A max
- Rated sensitivity:
- 30ma, 100ma, 300ma,500ma
- Breaking capacity:
- 1A
- Rated voltage:
- 230/400V
- Rated frequency:
- 50/60 Hz
- Material:
- Flame Resistant Plastic, brass
- Mechanical Life:
- 10000 or 20000 Times
- Standard:
- IEC61008, ISO9001, EAC
- Supply Ability:
- 1000000 Pole/Poles per Month rccb residual current circuit breaker
- Packaging Details
- Plastic shrink+Inner color box+standard export carton
Forrccb residual current circuit breaker
- Port
- Ningbo port
1.Product Description
Circuit breaker is a kind of switching device which can turn on, load and break the current in normal circuit and can turn on, load and break the current in abnormal circuit within a specified time.
2.Specification
Standard | IEC/EN 61008 | ||
Product | Earth Leakage Circuit Breaker | ||
Model | DZ30LE(1P+N) | ||
Electrical Features | Type(wave form of the earth leakage sensed) | A, AC | |
Rated Current | A | 6,10,16,20,25,32,40,50,63 | |
Number Of Poles | P | 1P+N | |
Rated Voltage Ue | V | AC230/400 | |
Rated Sensitivity | mA | 30,100,300 | |
Rated Frequency | Hz | 50/60 | |
SCPD Fuse | A | 10000 | |
Break Time Under In | S | ≤0.1 | |
Rated Impulse Withstand Voltage(1.2/50) Uimp | V | 6000 | |
Dielectric Test Voltage At Ind. Freq. For 1Min | KV | 2 | |
Pollution Degree | 2 | ||
Mechanical Features | Electrical Life | t | 4000 |
Mechanical Life | t | 10000 | |
Protection Degree | IP20 | ||
Storage Temperature | ℃ | -25-+70 | |
Installation | Terminal Size To p/buttom for cable | mm2 | 25 |
AWG | 18-3 |
Standard | IEC/EN 61009-1 | ||
Product | Residual Current Circuit Breaker | ||
Model | DZ47LE | ||
Electrical Features | Type(wave form of the earth leakage sensed) | A, AC | |
Rated Current | A | 6,10,16,20,25,32,40,50,63 | |
Number Of Poles | P | 1P+N or 2P or 3P or 3P+N or 4P | |
Rated Voltage Ue | V | AC230/400 | |
Rated Sensitivity | mA | 30,100,300 | |
Rated Frequency | Hz | 50/60 | |
Rated Breaking Capacity | A | 1 | |
Break Time Under In | S | ≤0.1 | |
Rated Impulse Withstand Voltage(1.2/50) Uimp | V | 4000 | |
Dielectric Test Voltage At Ind. Freq. For 1Min | KV | 2 | |
Pollution Degree | 2 | ||
Thermo-magnetic Release Characteristic Curve | C, D | ||
Mechanical Features | Electrical Life | t | 4000 |
Mechanical Life | t | 20000 | |
Protection Degree | IP20 | ||
Storage Temperature | ℃ | -25-+70 | |
Installation | Terminal Size To p/buttom for cable | mm2 | 25 |
AWG | 18-3 |
Standard | IEC/EN 61008 | ||
Product | Residual Current Circuit Breaker | ||
Model | E90LE(new type) | ||
Electrical Features | Type(wave form of the earth leakage sensed) | A, AC | |
Rated Current | A | 16,20,25,32,40,50,63 | |
Number Of Poles | P | 2P or 4P | |
Rated Voltage Ue | V | AC230/400 | |
Rated Sensitivity | mA | 30,100,300,500 | |
Rated Frequency | Hz | 50/60 | |
Break Time Under In | S | ≤0.1 | |
Rated Impulse Withstand Voltage(1.2/50) Uimp | V | 6000 | |
Dielectric Test Voltage At Ind. Freq. For 1Min | KV | 2.5 | |
Pollution Degree | 2 | ||
Thermo-magnetic Release Characteristic Curve | B,C | ||
Mechanical Features | Electrical Life | t | 6000 |
Mechanical Life | t | 20000 | |
Protection Degree | IP20 | ||
Storage Temperature | ℃ | -25-+70 | |
Installation | Terminal Size To p/buttom for cable | mm2 | 25 |
AWG | 18-3 |
Standard | IEC/EN 61008 | ||
Product | Residual Current Circuit Breaker | ||
Model | CT2 | ||
Electrical Features | Type(wave form of the earth leakage sensed) | A, AC | |
Rated Current | A | 16,20,25,32,40,50,63 | |
Number Of Poles | P | 2P or 4P | |
Rated Voltage Ue | V | AC230/400 | |
Rated Sensitivity | mA | 30,100,300 | |
Rated Frequency | Hz | 50/60 | |
Break Time Under In | S | ≤0.1 | |
Rated Impulse Withstand Voltage(1.2/50) Uimp | V | 6000 | |
Dielectric Test Voltage At Ind. Freq. For 1Min | KV | 2.5 | |
Pollution Degree | 2 | ||
Thermo-magnetic Release Characteristic Curve | B,C | ||
Mechanical Features | Electrical Life | t | 6000 |
Mechanical Life | t | 20000 | |
Protection Degree | IP20 | ||
Storage Temperature | ℃ | -25-+70 | |
Installation | Terminal Size To p/buttom for cable | mm2 | 25 |
AWG | 18-3 |
3.Details
4.Related Products
5.Application
Homes, industrial, buildings, etc. Sell well in Colombia market.
6.Packaging&Shipping
7.Certificate
8.FAQ
Q1: Can I have a sample for testing?
A: Yes, we can offer free sample, but you should afford the shipping cost.
Q2: Can I add my logo on the products?
A: Yes, OEM and ODM are available for us.
Q3: How can I get the after-service?
A: We will send you the free spare parts if the problems caused by us. If the products cannot be repaired, we will send
you new free quantity together with next order.
Q4: Do you have inspection procedures for products?
A: our products100% self-inspection and testing before packing.
Q5: Can I have a visit to your factory before the order?
A: Sure, welcome to visit our factory.
Here is our factory address: #7 Tongyi Industrial Area, Zhongshan City, Guzhen
Our factory is near Guangzhou airport, and we can pick you up in the airport, Hotel booking service is available.
Q6: How about delivery time of the order?
A: 15-20 days after getting deposit.
Q7: How about payment terms?
A: 20%-30% deposit, the rest payment balance against B/L. If have regular order and good order quantity, we can give
delay payment.
9.Contact Us