- Place of Origin:
- Shanghai, China
- Brand Name:
- SHCET
- Model Number:
- 3TB-SHCET
- Electricity Type:
- AC
- Number of Pole:
- 1,2,3,4
- Phase:
- 1,2,3,4
- Main Circuit Rating Voltage:
- 220V/230V380V/400V660V/690V
- Main Circuit Rating Current:
- 9A-630A
- Product name:
- AC/Magnetic/Modular Contactor
- Product type:
- contactor
- Rated current:
- 9A-630A
- Rated voltage:
- 220V/230V380V/400V660V/690V
- Rated frequency:
- 50/60 Hz
- Standard:
- IEC60947-4-1, ISO9001
- Sell well in:
- Europe, South America, etc.
- Supply Ability:
- 1000000 Piece/Pieces per Month
- Packaging Details
- Plastic shrink+Inner color box+standard export carton
- Port
- Ningbo port
1.Product Description
Contactors are divided into AC contactors (voltage AC), which are used in power, distribution and power applications. Contactors in a broad sense refer to electrical appliances that use coil current to generate magnetic field and close contacts in order to control load.
Because the main circuit of AC and DC can be switched off quickly and the device of high current control (up to 800A) circuit can be connected frequently, contactor is often used for motor as control object, and also for controlling power loads such as plant equipment, electric heater, working mother machine and various power units. Contactors can not only connect and cut off electricity. The circuit also has the function of low voltage release protection. Contactor control capacity is large, suitable for frequent operation and long-distance control, is one of the important components of automatic control system.
2.Specification
Type | Rated Thermal Current(A) | Rated Operating Current at AC 3 380V(A) | Rated Operating Current at 660V(A) | The Power of Controlled Motor(KW) | Type of Auxiliary Contact | |
380V | 660V | |||||
3TB40 | 20 | 9 | 3.3 | 4 | 5.5 | 1NO |
3TB41 | 20 | 12 | 4.3 | 5.5 | 7.5 | 1NC |
3TB42 | 30 | 16 | 7.7 | 7.5 | 11 | 1NO+1NC |
3TB43 | 30 | 22 | 8.5 | 11 | 11 | 2NO+2NC |
3TB44 | 45 | 32 | 12 | 15 | 23 | 2NC+2NO |
Standard | IEC/EN 60947-4-1 | ||||||||
Product | AC Contactor | ||||||||
Model | Rated Current(A) | Standard Power Ratings of 3-phase motors in AC-3(KW) | Number of the Poles | ||||||
220/230V | 380/400V | 415V | 440V | 500V | 660/690V | 1000V | 3P or 4P | ||
CJX1-F115 | 115A | 30 | 55 | 59 | 59 | 75 | 80 | 65 | |
CJX1-F150 | 150A | 40 | 75 | 80 | 80 | 90 | 100 | 65 | |
CJX1-F185 | 185A | 55 | 90 | 100 | 100 | 110 | 110 | 100 | |
CJX1-F225 | 225A | 63 | 110 | 110 | 110 | 129 | 129 | 100 | |
CJX1-F265 | 265A | 75 | 132 | 140 | 140 | 160 | 160 | 147 | |
CJX1-F330 | 330A | 100 | 160 | 180 | 200 | 200 | 200 | 160 | |
CJX1-F400 | 400A | 110 | 200 | 200 | 250 | 257 | 280 | 185 | |
CJX1-F500 | 500A | 147 | 250 | 280 | 295 | 355 | 335 | 335 | |
CJX1-F630 | 630A | 200 | 335 | 375 | 400 | 400 | 450 | 450 | |
CJX1-F780 | 780A | 220 | 400 | 425 | 425 | 450 | 475 | 450 | |
CJX1-F800 | 800A | 220 | 400 | 420 | 420 | 430 | 470 | 450 |
Standard | IEC/EN 60947-4-1 | |||||
Product | Air Conditioning Contactor | |||||
Model | Full Load Amps | Resistive Amps 600VAC | Locked Rotor Amps 240/277VAC | Locked Rotor Amps 480VAC | Locked Rotor Amps 600VAC | Coil Voltage |
1 Pole Contactor | ||||||
CJX9-1P | 20A | 30 | 120 | 100 | 80 | 24V;120V;208/240V;277V |
CJX9-1P | 25A | 35 | 125 | 125 | 100 | |
CJX9-1P | 30A | 40 | 125 | 125 | 100 | |
CJX9-1P | 40A | 50 | 160 | 160 | 120 | |
2 Pole Contactor | ||||||
CJX9-2P | 20A | 30 | 100 | 100 | 80 | 24V;120V;208/240V;277V |
CJX9-2P | 25A | 35 | 125 | 125 | 100 | |
CJX9-2P | 30A | 40 | 125 | 125 | 100 | |
CJX9-2P | 40A | 50 | 160 | 160 | 120 | |
3 Pole Contactor | ||||||
CJX9-3P | 20A | 30 | 120 | 100 | 80 | 24V;120V;208/240V;277V |
CJX9-3P | 25A | 35 | 150 | 125 | 100 | |
CJX9-3P | 30A | 40 | 180 | 150 | 100 | |
CJX9-3P | 40A | 50 | 240 | 200 | 120 | |
CJX9-3P | 50A | 44 | 300 | 250 | 200 | |
CJX9-3P | 60A | 75 | 360 | 300 | 240 | |
CJX9-3P | 75A | 90 | 450 | 375 | 300 | |
CJX9-3P | 90A | 120 | 540 | 450 | 360 | |
4 Pole Contactor | ||||||
CJX9-4P | 30A | 40 | 180 | 150 | 120 | 24V;120V;208/240V;277V |
CJX9-4P | 40A | 50 | 240 | 200 | 160 |
Standard | IEC/EN 60947-4-1 | ||||||||
Product | Contactor | ||||||||
Model | Rated Current(A) | Standard Power Ratings of 3-phase motors in AC-3(KW) | Electrical Life AC3(x10x4) | Mechanical Life AC3(x10x4) | Number of the Contacts | ||||
220/230V | 380/400V | 415V | 500V | 660/690V | |||||
CJX2-D09 | 9A | 2,2 | 4 | 4 | 5,5 | 5,5 | 100 | 1000 | 3P+NO; 3P+NC |
CJX2-D12 | 12A | 3 | 5,5 | 5,5 | 7,5 | 7,5 | 100 | 1000 | |
CJX2-D18 | 18A | 4 | 7,5 | 9 | 10 | 10 | 100 | 1000 | |
CJX2-D25 | 25A | 5,5 | 11 | 11 | 15 | 15 | 100 | 1000 | |
CJX2-D32 | 32A | 7,5 | 15 | 15 | 18,5 | 18,5 | 80 | 800 | |
CJX2-D40 | 40A | 11 | 18.5 | 22 | 22 | 30 | 80 | 800 | 3P+NO+NC |
CJX2-D50 | 50A | 15 | 22 | 25 | 30 | 33 | 60 | 800 | |
CJX2-D65 | 65A | 18.5 | 30 | 37 | 37 | 37 | 60 | 800 | |
CJX2-D80 | 80A | 22 | 37 | 45 | 55 | 45 | 60 | 600 | |
CJX2-D95 | 95A | 25 | 45 | 45 | 55 | 55 | 60 | 600 |
Standard | IEC/EN 60947-4-1 | ||||||||
Product | New Contactor | ||||||||
Model | Rated Current(A) | Standard Power Ratings of 3-phase motors in AC-3(KW) | Electrical Life AC3(x10x4) | Mechanical Life AC3(x10x4) | Number of the Contacts | ||||
220/230V | 380/400V | 415V | 500V | 660/690V | |||||
CJX2-D09 | 9A | 2,2 | 4 | 4 | 5,5 | 5,5 | 100 | 1000 | 3P+NO; 3P+NC |
CJX2-D12 | 12A | 3 | 5,5 | 5,5 | 7,5 | 7,5 | 100 | 1000 | |
CJX2-D18 | 18A | 4 | 7,5 | 9 | 10 | 10 | 100 | 1000 | |
CJX2-D25 | 25A | 5,5 | 11 | 11 | 15 | 15 | 100 | 1000 | |
CJX2-D32 | 32A | 7,5 | 15 | 15 | 18,5 | 18,5 | 80 | 800 | |
CJX2-D40 | 40A | 11 | 18.5 | 22 | 22 | 30 | 80 | 800 | 3P+NO+NC |
CJX2-D50 | 50A | 15 | 22 | 25 | 30 | 33 | 60 | 800 | |
CJX2-D65 | 65A | 18.5 | 30 | 37 | 37 | 37 | 60 | 800 | |
CJX2-D80 | 80A | 22 | 37 | 45 | 55 | 45 | 60 | 600 | |
CJX2-D95 | 95A | 25 | 45 | 45 | 55 | 55 | 60 | 600 |
Standard | IEC/EN 60947-4-1 | ||||||
Product | Magnetic Starter | ||||||
Model | Rated Current(A) | Standard Power Ratings of 3-phase motors in AC-3(KW) | Suitable Thermal Relay | ||||
|
| 220/230V | 380/400V | 415V | 500V | 660/690V |
|
LE1-D09 | 9A | 2,2 | 4 | 4 | 5,5 | 5,5 | LR2-D1312,D1314 |
LE1-D12 | 12A | 3 | 5,5 | 5,5 | 7,5 | 7,5 | LR2-D1316 |
LE1-D18 | 18A | 4 | 7,5 | 9 | 10 | 10 | LR2-D1321 |
LE1-D25 | 25A | 5,5 | 11 | 11 | 15 | 15 | LR2-D1322,D2353 |
LE1-D32 | 32A | 7,5 | 15 | 15 | 18,5 | 18,5 | LR2-D2355 |
LE1-D40 | 40A | 11 | 18,5 | 22 | 22 | 30 | LR2-D3353,D3355 |
LE1-D50 | 50A | 15 | 22 | 25 | 30 | 33 | LR2-D3357,D3359 |
LE1-D65 | 65A | 18,5 | 30 | 37 | 37 | 37 | LR2-D3361 |
LE1-D80 | 80A | 22 | 37 | 45 | 55 | 45 | LR2-D3363,D3365 |
LE1-D95 | 95A | 25 | 45 | 45 | 55 | 55 | LR2-D3365 |
Type | Rated working current of thermal relay | Thermal component | ||
Rated current(A) | Rated or scale of | |||
rated current (A) | ||||
LR2-D13 | 25 | LR2-D1301 | 0.16 | 0.10-0.16 |
LR2-D1302 | 0.25 | 0.16-0.25 | ||
LR2-D1303 | 0.4 | 0.25-0.40 | ||
LR2-D1304 | 0.63 | 0.40-0.63 | ||
LR2-D1305 | 1 | 0.63-1.0 | ||
LR2-D1306 | 1.6 | 1.0-1.6 | ||
LR2-D13x6 | 2 | 1.25-2.0 | ||
LR2-D1307 | 2.5 | 1.6-2.5 | ||
LR2-D1308 | 4 | 2.5-4.0 | ||
LR2-D1310 | 6 | 4.0-6.0 | ||
LR2-D1312 | 8 | 5.5-8.0 | ||
LR2-D1314 | 10 | 7.0-10.0 | ||
LR2-D1316 | 13 | 9.0-13.0 | ||
LR2-D1321 | 18 | 12.0-18.0 | ||
LR2-D1322 | 25 | 17.0-25.0 | ||
LR2-D23 | 36 | LR2-D2353 | 32 | 23.0-32.0 |
LR2-D2355 | 36 | 28.0-36.0 | ||
LR2-D33 | 93 | LR2-D3353 | 32 | 23.0-32.0 |
LR2-D3355 | 40 | 30.0-40.0 | ||
LR2-D3357 | 50 | 37.0-50.0 | ||
LR2-D3359 | 65 | 48.0-65.0 | ||
LR2-D3361 | 70 | 55.0-70.0 | ||
LR2-D3363 | 90 | 63.0-80.0 | ||
LR2-D3365 | 93 | 80.0-93.0 |
Standard | IEC/EN 60947-4-1 | ||
Product | Modular Contactor | ||
Model | Number of Poles | Rated Current(A) | Din-rail Width |
SHCET3-25 | 1P | 20A,25A | 18mm |
2P | 20A,25A | 18mm | |
SHCET4-63 | 1P | 32A,40A,63A | 36mm |
2P | 32A,40A,63A | 36mm | |
SHCET6-25 | 3P | 20A,25A | 36mm |
4P | 20A,25A | 36mm | |
SHCET5-63 | 3P | 32A,40A,63A | 54mm |
4P | 32A,40A,63A | 54mm |
3.Dimension&Mounting Size
4.More Products
5.Application
6.Packaging&Shipping
7.Certificate
8.FAQ
Q1: Can I have a sample for testing?
A: Yes, we can offer free sample, but you should afford the shipping cost.
Q2: Can I add my logo on the products?
A: Yes, OEM and ODM are available for us.
Q3: How can I get the after-service?
A: We will send you the free spare parts if the problems caused by us. If the products cannot be repaired, we will send
you new free quantity together with next order.
Q4: Do you have inspection procedures for products?
A: our products100% self-inspection and testing before packing.
Q5: Can I have a visit to your factory before the order?
A: Sure, welcome to visit our factory.
Here is our factory address: #7 Tongyi Industrial Area, Zhongshan City, Guzhen
Our factory is near Guangzhou airport, and we can pick you up in the airport, Hotel booking service is available.
Q6: How about delivery time of the order?
A: 15-20 days after getting deposit.
Q7: How about payment terms?
A: 20%-30% deposit, the rest payment balance against B/L. If have regular order and good order quantity, we can give
delay payment.
9.Contact Us