Homepage|Business Center|Save the Page|Get the App
普通会员

Shanghai CET Electric Co., Ltd.

Product Category
  • No Category Yet
Search
 
Link
  • No links
Home > Products > Wholesale High Quality Din Rail Watt Energy Meter
Wholesale High Quality Din Rail Watt Energy Meter
Click on the image to view the original image
Product: views:2Wholesale High Quality Din Rail Watt Energy Meter 
Branch: SHCET
Type: DDS366 series
Unit Price: Negotiated
Min.Order:
Supply:
Delivery: Shipment within days since the date of payment
Valid until: Long Term
Updated on: 2019-10-16 18:17
  Negotiated
Product Details
Overview
Quick Details
Place of Origin:
Shanghai, China
Brand Name:
SHCET
Model Number:
DDS366
Display Type:
Analog and Digital
Phase:
Single Phase/Three Phase, Single Phase
Measuring Energy Range:
1.5(6)A-30(100)A
Accuracy Class:
1.0 or 2.0
Output Voltage:
220-230V
Operating Temperature:
-25 ~+55
Dimensions:
117*60*18mm or others
Product name:
Electronic Type Watt-hour Energy Meter
Type:
DDS366 series
Condition:
100% new
OEM:
Avaliable
Standard:
IEC62053-21;
Rated Current:
1.5(6)A; 5(30)A; 10(40)A; 5(60)A; 20(80)A; 20(100)A; 30(100)A
Frequency:
50HZ/60HZ
Rated voltage:
220-230V
Supply Ability
Supply Ability:
1000000 Piece/Pieces per Month DDS366 Watt Hour Meter
Packaging & Delivery
Packaging Details
Plastic shrink+Inner color box+standard export carton
Port
Ningbo port

1.Product Description

DDS366 series electronic type watt-hour meter adopts the advanced SMT process and solid-state integrated circuit technology of ultra-low power consumption, it is used to measure the active electric energy of single-phase AC 50Hz or60Hz, all technical indexes are in conformity with IEC62053-21-2003,GB/T17215.321-2008 Electricity metering equipment (a.c.) – Particular requirements - Part 21: Static meters for active energy (classes 1 and 2) on single-phase static watt-hour meter.

 

 

2.Specification

StandardIEC  62053-21 
Productsingle-phase electronic type watt-hour meter
Model  CET-DDSY366-1P
Reference Voltage 220V-230V
Power Dissipation≤2W(10VA)
Rated Current1.5(6)A,5(20)A, 10(40)A, 15(60)A,20(80)A,30(100)A
Frequency50Hz or 60Hz
Accuracy Class1 or 2

 

StandardIEC  62053-21 
ProductSingle Phase Electronic Watt-hour Meter
Model  CET-DDSY366-2P
Reference Voltage 220V-230V
Power Dissipation≤2W(10VA)
Rated Current1.5(6)A,5(20)A,5(32)A,5(65)A, 10(40)A, 15(60)A
Frequency50Hz or 60Hz
Accuracy Class1

 

 

 

StandardIEC  62053-21 
Productsingle-phase electronic type watt-hour meter
Model  CET-DDSY366-4P
Reference Voltage 220V-230V
Power Dissipation≤2W(10VA)
Rated Current1.5(6)A,5(20)A, 10(40)A, 15(60)A,20(80)A,30(100)A
Frequency50Hz or 60Hz
Accuracy Class1 or 2

 

StandardIEC  62053-21 
Productthree-phase four wire watt-hour meter
Model  CET-DTS366-4P
Reference Voltage 3*220V/380V,3*230V/400V,3*240/415V
Power Dissipation≤2W(10VA)
Rated Current3*1.5(6)A,3*2.5(10)A,3*5(20)A, 3*10(60)A,3* 15(60)A,3*20(80)A
Frequency50Hz or 60Hz
Accuracy Class1

 

 

StandardIEC  62053-21 
Productthree-phase three/four wire watt-hour meter
Model  CET-DTS366-7P
Reference Voltage 3*100V,3*380V,3*57.7/100V,3*220V/380V
Power Dissipation≤2W(10VA)
Rated Current3*1.5(6)A,3*2.5(10)A,3*5(20)A, 3*10(60)A,3* 15(60)A,3*20(80)A,3*30(100)A
Frequency50Hz or 60Hz
Accuracy Class1 or 2

 

 

3.Funcions & Features

Stable measuring accuracy, general speaking, it would be free from effect of frequency, temperature, voltage or high order harmonic. After leaving the factory, it is unnecessary to make further regulation to the complete machine, it is allowable to prolong the verification period, which sharply reduces the testing and inspection work of power department, it has obviously advantage in reliability when comparing with other similar products.

Bi-directional measuring function, it is able to measure out the forward and reverse active energy accurately, and the reverse active energy would also be reckoned in forward value.

It is able to reserve the data of electric quantity permanently without help of standby battery.

The register will be driven by single chip directly, preventing pulse-loss phenomenon during power on or off, which guarantees consistency of meter reading data and register indicating value, avoids unnecessary dissension due to inconsistency of data.

Adoption of optical coupling isolated passive pulse output interface .

This meter is featured with wide load, high accuracy, high reliability, high sensitivity, straight error curve, low power consumption, small volume, light weight, energy saving, material saving, direct register display, etc.

 

4.Installation & Connection

Outline and installation dimension drawing

Wiring diagram

 

 

5.More Products

                                                      

6.Application

Ambient conditions Standard working temperature: -25℃~55℃Limiting working temperature: -25℃~60℃ Note: limiting working temperature for special requirements: -40℃~70℃.

 

 

7.Packaging&Shipping

 

 

8.Certificate

 

 

9.FAQ

Q1: Can I have a sample for testing?

A: Yes, we can offer free sample, but you should afford the shipping cost.

Q2: Can I add my logo on the products?

A: Yes, OEM and ODM are available for us.

Q3: How can I get the after-service?

A: We will send you the free spare parts if the problems caused by us. If the products cannot be repaired, we will send

you new free quantity together with next order.

Q4: Do you have inspection procedures for products?

A: our products100% self-inspection and testing before packing. 

Q5: Can I have a visit to your factory before the order?

A: Sure, welcome to visit our factory.

Here is our factory address:  #7 Tongyi Industrial Area, Zhongshan City, Guzhen

Our factory is near Guangzhou airport, and we can pick you up in the airport,   Hotel booking service is available.

Q6: How about delivery time of the order?

A: 15-20 days after getting deposit.

Q7: How about payment terms?

A:  20%-30% deposit, the rest payment balance against B/L. If have regular order and good order quantity, we can give

delay payment.

 

10.Contact Us 

 

 

 

 

 

 

 

 

询价单
total0items  Comments