- Place of Origin:
- SHENZHEN
- Brand Name:
- df
- Model Number:
- 168n-9w-180
- Output Power:
- 1 - 50W
- Output Type:
- DUAL
- Input Voltage:
- AC100-265, AC 85-265V
- Output Voltage:
- AC100-265
- Output Frequency:
- 50-60
- Output Current:
- 0.1-2A
- Product Name:
- Fire Emergency Lights
- Battery:
- lithium-iron battery
- Charge time:
- 24 Hours
- Warranty:
- 2 YEARS
Packaging & Delivery
- Selling Units:
- Multiple of
- Package size per batch:
- 29X5X3 cm
- Gross weight per batch:
- 0.85 kg
- Package Type:
- 20PCS/BOX
- Lead Time:
Quantity(Piece) 1 - 10 11 - 100 101 - 1000 >1000 Est. Time(days) 1 2 7 To be negotiated
168N LED lamp emergency power supply Lighting for over 180 minutes
1. Emergency power supply Box(9W 180min)
Types of lamps : LED 9W Inverter model: DF168N 3G
Input: AC100-280V/50-60HZ Battery pack: Li-ion battery pack 7.2V 5000mAh
Output AC/DC100-280V Weight: 0.6kg
3.The installation and operation instruction
(1)—— 1: accordance with writing diagram to connect the circuit in strict. The following lines are connected to each port:
1 —— connect Live Wire L+ Connect switch line
2 —— connect the Neutral line N
3——Connect the ground wire.
4 5—— Connect light source (suit for LED light source with inside drive).
4 5—— Connect driver power, and connect light source (suit for LED light source with outside driver)
6—— Connect switch line. The other side of switch line, Enter the fire wire1 port. Swith line and Live wire must Keep with the phase.Wall switch only control utility lighting, not affect the emergency lighting
4.note:
1 .This product should be installed by trained electricians. Forbid connecting wires when power is on, make power on after make sure that there is no phenomenon of short circuit and the correction is ok.
2. Main power line: Live wire TL and null line N, connect to main power line directly. no switch can be allowed when emergency lighting. the law forbids the switch control emergency circuit.
3 .The wall switch only controls the main power, no function on emergency lighting. The Switch live wire SL and charging live wire TL should be in the same phase.
4. Green light-main power ,Red light-charging , Yellow light-mulfunction;Test: test button
5.Emergency lighting condition,three-color light is all out;
6. Digital circuits, self-test function (monthly inspection, annual inspection), fault or automatic alarm function cause by illegal operation.
7 .You should connect the led lamp and charge the emergency pack before use. In order to avoid emergency lighting function failure.
8 .The environment temperature of Emergency pack ranges from minus ten degrees centigrade to 50 degrees centigrade. High-temperature aging test is forbidded.
9 .Frequently test is prohibited . Each test interval is not less than one minute.
10 .Emergency movement is the core device which controls the battery charge or discharge and start the lighting when under emergency must ensure the wiring is correct. After under normal use, need to discharge once every three months for battery conservation and extend the battery life. Emergency lighting power installed and put into use, need to regularly check, maintain, examine and repair when discover the abnormal condition, or inform the supplier to deal with.
11 .Any problem, contact the manufacturer or supplier pls.