- Place of Origin:
- Guangdong, China
- Brand Name:
- DF LARES
- Bulb Type:
- LED
- Battery Type:
- NI-CD battery
- Material:
- Cold Rolled Steel Sheet
- Usage:
- emergency lighting
- Certification:
- SAA CE TUV ROHS FCC
- Specifications:
- 168-30H-20W180MIN
- Product Name:
- Fire Emergency Lights
- Input Voltage:
- AC 85-265V
- Battery:
- NI-CD battery
- Charge time:
- 24 Hours
- Warranty:
- 36W40W60W72W80W
Packaging & Delivery
- Selling Units:
- Multiple of
- Package size per batch:
- 47X33X2500 cm
- Gross weight per batch:
- 2600.0 kg
- Package Type:
- 4PCS/BOX
- Lead Time:
Quantity(Piece) 1 - 100 101 - 1000 1001 - 10000 >10000 Est. Time(days) 2 7 30 To be negotiated
36W40W60W80W50% 3hs LED emergency power kit, DF emergency battery pack with CE FCC TUV ETL
DF168-30H can automatically test light chip"s series and adjust the output voltage to best match between the inverter and the load, providing 20w~25w illumination customized.DF168-30H uses IC control circuit, has constant output power, isolation circuit, no-load protection feature.2.Emergency lighting parameters
Emergency power: 20±1W
Charging time: ≥30hours
Duration time: ≥180min
Conversion efficiency ≥80%
Power factor ≥90%
Emergency switching time: ≤ 1S
Lighting system continuous
The service life 20000hours
Temperature range -10-55℃
Humidity range 65%±20%
3.The installation and operation instruction
1—— Connect LiveWire L+ LED external driver live wire input. This line can set a wall switch S. The wall switch only controls the main power, no function on emergency lighting.
2—— Connect the neutral line N+LED external driver neutral line input
3——Connect the earth wire.
4—— connect LED driver’s output positive
5—— connect light source’s negative +light source external driver’s output negative
6—— light positive
4.note:
1 .Accordance with writing diagram to connect the circuit in strict,and pay attention to distinguish between the zero line and fire wire.
2 .Forbid connecting line when the mains, please wiring by professional electrician. You should cut off the mains then wiring.
3. Main power line: fire line L and zero line N, connect to main power line directly. no switch can be allowed when emergency lighting. the law forbids the switch control emergency circuit.
4 .The wall switch only controls the main power, no function on emergency lighting.
5 Green light-main power ,Red light-charging , Yellow light-mulfunction;
6 Emergency lighting condition,three-color light is all out;
7 Digital circuits, self-test function (monthly inspection, annual inspection), fault or automatic alarm function cause by illegal operation.
8.Emergency core module is a device which controls the battery charging and discharging, and start lights illumination. Please be sure the wiring is correct before your run our products.
"9.In normal use of electricity, it should discharge once every three months for battery conservation, and to extend battery life.
After the emergency lights power installation into use, there should set a special position for regular inspection and maintenance, and be timely maintenance or notify the supplier when abnormal situation was found."