Homepage|Business Center|Save the Page|Get the App
普通会员

Shenzhen EVEN Technology Co., Ltd.

Product Category
  • No Category Yet
Search
 
Link
  • No links
Home > Products > High emergency power battery 100% brightness for led lighting tubes
High emergency power battery 100% brightness for led lighting tubes
Click on the image to view the original image
Product: views:4High emergency power battery 100% brightness for led lighting tubes 
Branch: EVEN emergency power battery
Unit Price: Negotiated
Min.Order:
Supply:
Delivery: Shipment within days since the date of payment
Valid until: Long Term
Updated on: 2019-10-17 01:19
  Negotiated
Product Details
Overview
Quick Details
Warranty(Years):
3
Input Voltage(V):
85-265V
Lamp Power(W):
30
Lamp Luminous Efficiency(lm/w):
230
CRI (Ra>):
85
Working Temperature(℃):
-20 - 40
Working Lifetime(Hour):
50000
Lamp Body Material:
Aluminum
IP Rating:
IP65
Certification:
CE, EMC, LVD, RoHS
Place of Origin:
Guangdong, China
Brand Name:
EVEN emergency power battery
Model Number:
emergency power battery
Light Source:
LED
Key Product:
emergency power battery
Advantages:
good quqlity ,long cycle life
Input Voltage:
AC 85-280V, 50-60Hz
Normal Capacity:
1000mah-5000mah
Working Life:
50000hours
Usage:
Luminaires
Size:
Customized
Emergency duration:
1/2/3hrs
Emergency Brightness:
30%-100%
Warrenty time:
36months
Item Type:
Tube Lights
Color Temperature(CCT):
Warm White
LED Light Source:
22-24LM
Lamp Luminous Flux(lm):
80%-100%
Supply Ability
Supply Ability:
9999999 Piece/Pieces per Day emergency power battery
Packaging & Delivery
Packaging Details
emergency power battery insulated package
Port
Shenzhen/HongKong
Lead Time:
Within 15 days as normal order

High emergency power battery 100% brightness for led lighting tubes   

 

Emergency Kit for LED Tube

 

1.      Model: EMI-LT

EMI-LT emergency pack is a newly designed type. It is tailor-made for LED Tubes or other driver equipped LED Lighting.

 

The emergency power kit equipped with the inverter, battery pack and the necessary accessories.The control circuit monitors the mains supply, if the light works as normal, the inverter allows the charger to trickle charge the battery pack in standby mode. In the event of an earthquake, explosion,accident or other emergency which results in the AC power supply to fail, the inverter automatically activates the battery backup system and switches the light on in less than 0.1 second. The system can be programmed emergency running time of 1 /2/ 3/4 hours depending on different battery packs to meet the requirements under various conditions.

 

2.Range of Application

 

-EMI-LT is applicable for 1W to 60W LED Tube Emergency lighting,Emergency output

power is 1W to 60W, Emergency duration is from 0.5 to 4hours.

- EMI-LT is also applicable for any internal driver equipped led lighting,.

- Operates in -25-+70 environment temperature.

- Instruction manual

 

3.Product Feature

 

1. Intelligent automatic recharging and converting function

2. Constant current battery charger

3. 1/2/3 hours emergency operation

4. Led charge status display

5. Inverter with multiple protection functions:charge protection,discharge protection,

short circuit protection

6. Facility for a Test switch to inspect between Emergency and normal lighting function

7. Supplied with high brightness green/Red LED (manual test)

8. Complete with flex and plug

9. Push-wire terminal blocks for easy wiring installation

10. High quality of NiCD rechargeable battery with 2 years of life.

11. Small volume, convenient and flexible installation

 

 

4.Technical Specification

 

TYPE:EMI-LT

Applicable for : led tube light

Applicable for lamp power : 1-60W

Inner package material : high quality cold-rolled steel plate spray white and environment friendly paint

Charging power: AC110V-AC265V,50HZ/60HZ;

Emergency time:1-3hrs

Emergency power level:100%

Emergency output voltage: DC220~310V/DC220~310V (Option)

Inverter Dimension : 166*41*29mm

Emergency Conversion time:0.1sec

Charging time :24hour

Battery: To be configured with different backup period and different light output levels.

 

5.Emergency Solution:

1. According to EN60598; EN 55015; CE;

2. Deep discharge protection

3. Operation time (discharge):1hour(Customized within 1hr)

4.Lumen Factor : 100%

5.Emergency Output:DC220V

6.Matched Emergency Solution : 12V/2.0Ah Ni-CD Battery + Inverter+ Metal Box+ Inner Box

 

6. Dimension (mm ):

  Battery Size : C type (50*25mm/cell)

  Inverter Size : 166*41*29mm

 

7.Application:

Product name: Emergency module for LED Tube

 

 

8.Usage range:

 

Hotels

Conference/Meeting rooms

Factories & Offices

Commercial Purposes

Residential/Institution Buildings

Schools, Colleges & Universities

Hospitals

Places where energy saving and high color rendering index lightings are required

 

 

9.Installation

 

-. L (line) and N (neutral) must be always charged, external connection with control switch is

prohibited.

-. Strictly comply with the wiring diagram to connect circuit in other conditions

 

10.Wiring Diagram:

 

 

 

 

Attentions:

-          Pay extra attention to the negative and the positive pole of the battery in order to prevent

reverse operation, please use designated and matching batteries and ensure all wiring is done

correctly and stable before use.

-  If you need to do product testing, unplug the battery pack when the emergency device is

disconnected from the mains supply, and then plug in the battery after the emergency device is

completely shut down.

-           Comply with the wiring connection circuit diagram completely, prevent from over loading and

non loading in the process of use and testing.

-          In order to prolong the battery powered lighting time, all indicator lights are switched off

during normal use with the emergency power system in standby mode.

-           The battery is not charged before leaving the factory; please charge the battery longer than 24

hours before use.

-          In general, the battery needs to be fully charged and discharged for around 3- 5 times in order

for the Ni-CD/Ni-MH battery to operate at full capacity.

8-  It is detrimental for the Ni-CD/Ni-MH battery to lie idle for a long time, especially when it runs

dead. Charge the battery completely when it is out of operation for a long time. (The battery cannot

lie idle for more than three months)

 

Important:

 

It is recommended that the module is installed by a competent person ensuring the installation complies with the necessary standards. EVEN accepts no responsibility for injury, damage or loss, which may arise as a result of incorrect installation, operation or maintenance. the conversion requires an unswitched supply for charging the battery and a switched supply for a maintained conversion.Ensure that the finished converted luminaire operates within the module and battery temperature ratings.Ensure that the original luminaire components are still operating within their temperature ratings.

 

Note the production date of the battery.

-Charge the battery completely when it is out of operation over 3 month.

-Check the emergency module functionality for 3 month intervals.

-Replace the battery every 3 years interval

 

 

 

 

 

询价单
total0items  Comments