Home > Products > 2 Wire LPCB 2 Zone Conventional Fire Alarm Panel
2 Wire LPCB 2 Zone Conventional Fire Alarm Panel
Click on the image to view the original image
Product: views:42 Wire LPCB 2 Zone Conventional Fire Alarm Panel 
Branch: Guta
Unit Price: Negotiated
Min.Order:
Supply:
Delivery: Shipment within days since the date of payment
Valid until: Long Term
Updated on: 2019-10-16 23:13
  Negotiated
Product Details
Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
Guta
Model Number:
GT-P1002
Product name:
Wholesale 2 Zone Conventional Detection Panel
Capacity:
2 zone
Usage:
Fire protection
Color:
Red or as customized
Circus Bus:
2-wire Bus System
Installation:
Wall- Mouned
Certificates:
CE;LPCB; ISO9001
Executive Standaed:
GB19880-250
Brand:
Guta
Mains Supply Voltage:
110VAC/220VAC
Supply Ability
Supply Ability:
200000 Piece/Pieces per Week
Packaging & Delivery
Port
Zhongshan
Product Description

 

2 Zone Conventional Detection Panel 

ITEM

1Zone panel

2Zone panel

4-8Zone panel

4-32 Zone panel

Model No.

AW-CFP2166-01

AW-CFP2166-02

AW-CFP2166-04-8

AW-CFP2166-04-32

Power specification

 

Mains supply voltage

110VAC or 240VAC

Internal power supply

27.2VDC

Total output current limited

500mA @240VAC

500mA @240VAC

3A @ 240VAC

3A @ 240VAC

Main supply monitor for fault

Yes

Battery protection for low voltage

Yes

Batteries (default configuration)

12V2AH*2

Detector circuit specification

 

Number of circuit

1

2

4-8

4-32

Line fault monitor for open circuit

Yes

Line fault monitor for short circuit

Yes

Line fault monitor for detector removal

Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor

End of Line device

6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)

Detector continuity diodes

Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)

Call point resistor value

470 to 680 Ω, 0.225 or 0.5 watt

Maximum number of smoke/heat detectors per zone

20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.

Maximum number of manual call points per zone

No limit

Sounder circuit specification

 

Number of general circuits

2

End of line resistor value

6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)

Line fault monitor for open circuit

Yes

Line fault monitor for short circuit

Yes

Outputs fused AT

400mA

Maximum number of bells @ 20mA of each sounder output

20

Fuses

 

27VDC fuse

3A F 20mm

Fire and fault output

 

Output type

Dry relay output :NC and NO relay; wet source output

Maximum current

100mA

Connection block

 

Largest acceptable conductor size

2.5mm2

Smallest acceptable conductor size

0.75mm2

Size and weight

 

 

Dimensions(mm)

272*200*70mm

320*231*90mm

395X502X124

362X565X124

Weight (without batteries)

4kg

5kg

7kg

8kg

Weight (with batteries)

5.8kg

6.8kg

9.6kg

12.5k

   conventional fire alarm, addressable fire alarm, fire alarm system, fire alarm panel, fire alarm control, alarm control system, with smoke

 conventional fire alarm, addressable fire alarm, fire alarm system, fire alarm panel, fire alarm control, alarm control system, with smoke detector, with heat detector, heat smoke sensor, fire fighting, security fire alarm system 

etector, with heat detector, heat smoke sensor, fire fighting, security fire alarm system    conventional fire alarm, addressable fire alarm, fire alarm system, fire alarm panel, fire alarm control, alarm control system, with smoke detector, with heat detector, heat smoke sensor, fire fighting, security fire alarm system 

Packaging & Shipping

Packaging Details: Standard safety export package / carton (Box + Foam) or as customized

Delivery Detail: one week

 

Our Services

1.    OEM/ODM services.

2.    Professional technical team.

3.    Offer Free technical support whenever you need.

4.    One year warranty and technical maintenance

 

 

Company Information

       Zhongshan Guta Fire Equipment Tecnology Co., Ltd is manufacturer of fire alarm and fire suppression system since 2005.Our headquarter is in London ,UK,withoffice in Shenzhen and factorty in Zhongshan.We keep our best service for our customers,and have a rich experienced engineer team to design and istall for overseas projects.Most of products have CE certificates and some have UL and LPCB approcal.

Our product range:Addressable Fire Alarm System,Conventioanl Fire Alarm System,FM200 Gas Suppression System,Fire Pump,Fire Hose/hose reel cabinet,ABC Power/CO2 Fire Extinguish/Emergency Light System.

 

 

 

 

Certifications

 

FAQ

 

* How long is the delivery time ?

   Usually about 2 to 7 days. Mass production about 3 weeks.

 

* Do we have technical support ?

   Yes, we have a professional engineering team.

 

* How to assure the quality ?

   Firstly, all of our materials and components pass the serious China Quality Standard and Control.

   Secondly, all of our finished products only can pass Asenware Quality Check System, then can export.

   Thirdly, our products can be provided to test and cetify by Authories according to customer"s special need.

 

* Do we have warranty ?

   Yes, One year or more depends.

 

* Sample for testing ?

   Yes, Stock sample or Customized sample is available.

 

* Procedure to Purchase our products ?

   Inquiry --- Offer --- Dicssion --- Confirmation --- Order --- Deposit --- Production --- Payment --- Shipment --- Arrival --- Finished --- Feedback --- Repeat Order. 

 

Conventional Detection Panel , Conventional Detection Panel , Conventional Detection Panel

询价单
total0items  Comments