- Place of Origin:
- Guangdong, China
- Brand Name:
- Guta
- Model Number:
- GT-P1002
- Product name:
- Wholesale 2 Zone Conventional Detection Panel
- Capacity:
- 2 zone
- Usage:
- Fire protection
- Color:
- Red or as customized
- Circus Bus:
- 2-wire Bus System
- Installation:
- Wall- Mouned
- Certificates:
- CE;LPCB; ISO9001
- Executive Standaed:
- GB19880-250
- Brand:
- Guta
- Mains Supply Voltage:
- 110VAC/220VAC
- Supply Ability:
- 200000 Piece/Pieces per Week
- Port
- Zhongshan
2 Zone Conventional Detection Panel
ITEM | 1Zone panel | 2Zone panel | 4-8Zone panel | 4-32 Zone panel |
Model No. | AW-CFP2166-01 | AW-CFP2166-02 | AW-CFP2166-04-8 | AW-CFP2166-04-32 |
Power specification |
| |||
Mains supply voltage | 110VAC or 240VAC | |||
Internal power supply | 27.2VDC | |||
Total output current limited | 500mA @240VAC | 500mA @240VAC | 3A @ 240VAC | 3A @ 240VAC |
Main supply monitor for fault | Yes | |||
Battery protection for low voltage | Yes | |||
Batteries (default configuration) | 12V2AH*2 | |||
Detector circuit specification |
| |||
Number of circuit | 1 | 2 | 4-8 | 4-32 |
Line fault monitor for open circuit | Yes | |||
Line fault monitor for short circuit | Yes | |||
Line fault monitor for detector removal | Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor | |||
End of Line device | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) | |||
Detector continuity diodes | Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault) | |||
Call point resistor value | 470 to 680 Ω, 0.225 or 0.5 watt | |||
Maximum number of smoke/heat detectors per zone | 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts. | |||
Maximum number of manual call points per zone | No limit | |||
Sounder circuit specification |
| |||
Number of general circuits | 2 | |||
End of line resistor value | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) | |||
Line fault monitor for open circuit | Yes | |||
Line fault monitor for short circuit | Yes | |||
Outputs fused AT | 400mA | |||
Maximum number of bells @ 20mA of each sounder output | 20 | |||
Fuses |
| |||
27VDC fuse | 3A F 20mm | |||
Fire and fault output |
| |||
Output type | Dry relay output :NC and NO relay; wet source output | |||
Maximum current | 100mA | |||
Connection block |
| |||
Largest acceptable conductor size | 2.5mm2 | |||
Smallest acceptable conductor size | 0.75mm2 | |||
Size and weight |
|
| ||
Dimensions(mm) | 272*200*70mm | 320*231*90mm | 395X502X124 | 362X565X124 |
Weight (without batteries) | 4kg | 5kg | 7kg | 8kg |
Weight (with batteries) | 5.8kg | 6.8kg | 9.6kg | 12.5k |
conventional fire alarm, addressable fire alarm, fire alarm system, fire alarm panel, fire alarm control, alarm control system, with smoke
conventional fire alarm, addressable fire alarm, fire alarm system, fire alarm panel, fire alarm control, alarm control system, with smoke detector, with heat detector, heat smoke sensor, fire fighting, security fire alarm system
etector, with heat detector, heat smoke sensor, fire fighting, security fire alarm system conventional fire alarm, addressable fire alarm, fire alarm system, fire alarm panel, fire alarm control, alarm control system, with smoke detector, with heat detector, heat smoke sensor, fire fighting, security fire alarm system
Packaging Details: Standard safety export package / carton (Box + Foam) or as customized
Delivery Detail: one week
* Over 10 years" experience.
* Prompt response.
* OEM & ODM available.
* Support factory inspection.
* Standard qulity control system.
* Different choices of payment and delivery.
* Independant R&D dept, designing dept,to meet your special need.
* Whole set of technical supports and with abroad projects experience.
* We are manufacturer, offer better price better service.
* Direct control on materials, production status, quality checking.
* Sample order, customized order, bulk order are supported.
* Reliable after-sales service, with one year waranty.
Zhongshan Guta Fire Equipment Tecnology Co., Ltd is manufacturer of fire alarm and fire suppression system since 2005.Our headquarter is in London ,UK,withoffice in Shenzhen and factorty in Zhongshan.We keep our best service for our customers,and have a rich experienced engineer team to design and istall for overseas projects.Most of products have CE certificates and some have UL and LPCB approcal.
Our product range:Addressable Fire Alarm System,Conventioanl Fire Alarm System,FM200 Gas Suppression System,Fire Pump,Fire Hose/hose reel cabinet,ABC Power/CO2 Fire Extinguish/Emergency Light System.
* How long is the delivery time ?
Usually about 2 to 7 days. Mass production about 3 weeks.
* Do we have technical support ?
Yes, we have a professional engineering team.
* How to assure the quality ?
Firstly, all of our materials and components pass the serious China Quality Standard and Control.
Secondly, all of our finished products only can pass Asenware Quality Check System, then can export.
Thirdly, our products can be provided to test and cetify by Authories according to customer"s special need.
* Do we have warranty ?
Yes, One year or more depends.
* Sample for testing ?
Yes, Stock sample or Customized sample is available.
* Procedure to Purchase our products ?
Inquiry --- Offer --- Dicssion --- Confirmation --- Order --- Deposit --- Production --- Payment --- Shipment --- Arrival --- Finished --- Feedback --- Repeat Order.