- Place of Origin:
- Guangdong, China
- Brand Name:
- GUTAFIRE
- Model Number:
- GT-P1002
- Product name:
- Wholesale 2 Zone Conventional Detection Panel
- Capacity:
- 2 zone
- Usage:
- Fire protection
- Color:
- Red or as customized
- Circus Bus:
- 2-wire Bus System
- Installation:
- Wall- Mouned
- Certificates:
- CE IS09001
- Mains supply voltage:
- 110VAC or 240VAC
- Zone:
- 1/2/4/8/12/16/20/24/28/32 Zones
- Dimensions:
- 272*200*70
- Supply Ability:
- 200000 Piece/Pieces per Week
- Port
- Zhongshan
1. The series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2. It is modularized design, the panel can expend from 1 zone to 32 zones easily.
3. It has 2 level control mode by a lock
4. It has 27VDC power supply output.
5. It has FIRE PROTECTION, FIRE ROUTING and FAULT signal output, the output can be configured to dry relay type or wet sources type.
6. It has 2 channel general sounders output.
7. Each zone has 1 circuit detectors input .
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. It has SILENCE button to stop BUZZER and SOUNDERS.
11. It has EVACUATE button to start a manual fire alarm immediately.
12. It has TEST button to test all LEDs orderly.
13. It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
14. It has an optional GSM module for fire alarm by SMS .
15. It is economic, user-friendly and easy maintenance.
2 Zone Conventional Detection Panel , 2 ZoneConventional Detection Panel , 2 Zone Conventional Detection Panel
ITEM | 1Zone panel | 2Zone panel | 4-8Zone panel | 4-32 Zone panel |
Model No. | AW-CFP2166-01 | AW-CFP2166-02 | AW-CFP2166-04-8 | AW-CFP2166-04-32 |
Power specification |
| |||
Mains supply voltage | 110VAC or 240VAC | |||
Internal power supply | 27.2VDC | |||
Total output current limited | 500mA @240VAC | 500mA @240VAC | 3A @ 240VAC | 3A @ 240VAC |
Main supply monitor for fault | Yes | |||
Battery protection for low voltage | Yes | |||
Batteries (default configuration) | 12V2AH*2 | |||
Detector circuit specification |
| |||
Number of circuit | 1 | 2 | 4-8 | 4-32 |
Line fault monitor for open circuit | Yes | |||
Line fault monitor for short circuit | Yes | |||
Line fault monitor for detector removal | Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor | |||
End of Line device | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) | |||
Detector continuity diodes | Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault) | |||
Call point resistor value | 470 to 680 Ω, 0.225 or 0.5 watt | |||
Maximum number of smoke/heat detectors per zone | 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts. | |||
Maximum number of manual call points per zone | No limit | |||
Sounder circuit specification |
| |||
Number of general circuits | 2 | |||
End of line resistor value | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) | |||
Line fault monitor for open circuit | Yes | |||
Line fault monitor for short circuit | Yes | |||
Outputs fused AT | 400mA | |||
Maximum number of bells @ 20mA of each sounder output | 20 | |||
Fuses |
| |||
27VDC fuse | 3A F 20mm | |||
Fire and fault output |
| |||
Output type | Dry relay output :NC and NO relay; wet source output | |||
Maximum current | 100mA | |||
Connection block |
| |||
Largest acceptable conductor size | 2.5mm2 | |||
Smallest acceptable conductor size | 0.75mm2 | |||
Size and weight |
|
| ||
Dimensions(mm) | 272*200*70mm | 320*231*90mm | 395X502X124 | 362X565X124 |
Weight (without batteries) | 4kg | 5kg | 7kg | 8kg |
Weight (with batteries) | 5.8kg | 6.8kg | 9.6kg | 12.5kg |
Packaging Details: Standard safety export package / carton (Box + Foam) or as customized
Delivery Detail: one week
1. OEM/ODM services.
2. Professional technical team.
3. Offer Free technical support whenever you need.
4. One year warranty and technical maintenance
Guta, professional manufacturer of fire alarm and fire suppression system since 2005.Our headquarter is in London,UK, with factory Shenzhen,China.
Our company"s products have passed CE certification, SASO certification, other international certification is also in the process. We keep our best service for our customers, and have 12 years of export experience with a technologically advanced team of engineers to design and install for overseas project.
Product range:
Addressable fire alarm system(2100 series for Big project,2189 series for small project)
Conventional fire alarm system(2166 series)
FM200 gas suppression system(2159 series)
Fire pump
Fire hose/hose reel and cabinet
Abc powder/co2 fire extinguisher
Emergency light system
Q1:Can I have a sample order?
A:Yes,we welcome sample order to test and check quality.
Q2:What is the lead time?
A:Sample needs 1-3 days, mass product according to your quantity.
Q3:How do you ship the goods and how long does it take arrive?
A:We usually ship by DHL,UPS,FedEX or by Air. 3-5 days after payment received.
Q4:Do you guarantee for the products?
A:Yes,we offer one year guarantee for the products.
Q5:Do you offer OEM service?
A:Yes,we can design the products according to your request.