Homepage|Business Center|Save the Page|Get the App
普通会员

Zhongshan Guta Fire Equipment Technology Co., Ltd.

Product Category
  • No Category Yet
Search
 
Link
  • No links
Home > Products > Conventional 2 Wire 2 Zone Alarm Control Panel 2166 Series
Conventional 2 Wire 2 Zone Alarm Control Panel 2166 Series
Click on the image to view the original image
Product: views:2Conventional 2 Wire 2 Zone Alarm Control Panel 2166 Series 
Branch: GUTAFIRE
Unit Price: Negotiated
Min.Order:
Supply:
Delivery: Shipment within days since the date of payment
Valid until: Long Term
Updated on: 2019-10-16 23:14
  Negotiated
Product Details
Overview
Quick Details
Brand Name:
GUTAFIRE
Model Number:
GT-P1002
Product name:
Conventional 2 Wire 2 ZoneAlarm Control Panel 2166 Series
Capacity:
1-32 zone
Circus Bus:
2 Bus System
Color:
Red or as customized
Mode:
Conventional
Installation:
Wall- Mouned
Certificates:
CE IS09001
Usage:
Fire protection
Supply Ability
Supply Ability:
200000 Piece/Pieces per Week
Packaging & Delivery
Port
Zhongshan
Product Description

 

2 Zone Fire alarm panel ,2 Zone Fire alarm panel ,2 Zone Fire alarm panel

ITEM

1Zone panel

2Zone panel

4-8Zone panel

4-32 Zone panel

Model No.

AW-CFP2166-01

AW-CFP2166-02

AW-CFP2166-04-8

AW-CFP2166-04-32

Power specification

 

Mains supply voltage

110VAC or 240VAC

Internal power supply

27.2VDC

Total output current limited

500mA @240VAC

500mA @240VAC

3A @ 240VAC

3A @ 240VAC

Main supply monitor for fault

Yes

Battery protection for low voltage

Yes

Batteries (default configuration)

12V2AH*2

Detector circuit specification

 

Number of circuit

1

2

4-8

4-32

Line fault monitor for open circuit

Yes

Line fault monitor for short circuit

Yes

Line fault monitor for detector removal

Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor

End of Line device

6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)

Detector continuity diodes

Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)

Call point resistor value

470 to 680 Ω, 0.225 or 0.5 watt

Maximum number of smoke/heat detectors per zone

20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.

Maximum number of manual call points per zone

No limit

Sounder circuit specification

 

Number of general circuits

2

End of line resistor value

6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)

Line fault monitor for open circuit

Yes

Line fault monitor for short circuit

Yes

Outputs fused AT

400mA

Maximum number of bells @ 20mA of each sounder output

20

Fuses

 

27VDC fuse

3A F 20mm

Fire and fault output

 

Output type

Dry relay output :NC and NO relay; wet source output

Maximum current

100mA

Connection block

 

Largest acceptable conductor size

2.5mm2

Smallest acceptable conductor size

0.75mm2

Size and weight

 

 

Dimensions(mm)

272*200*70mm

320*231*90mm

395X502X124

362X565X124

Weight (without batteries)

4kg

5kg

7kg

8kg

Weight (with batteries)

5.8kg

6.8kg

9.6kg

12.5kg




Company Information

Guta, professional manufacturer of fire alarm and fire suppression system since 2005.Our headquarter is in London,UK, with factory Shenzhen,China.

Our company"s products have passed CE certification, SASO certification, other international certification is also in the process. We keep our best
service for our customers, and have 12 years of export experience with a technologically advanced team of engineers to design and install for overseas project.

 

Product range:

Addressable fire alarm system(2100 series for Big project,2189 series for small project)
Conventional fire alarm system(2166 series)
FM200 gas suppression system(2159 series)
Fire pump
Fire hose/hose reel and cabinet
Abc powder/co2 fire extinguisher
Emergency light system

 

 

Packaging & Shipping

Packaging Details: Standard safety export package / carton (Box + Foam) or as customized

Delivery Detail: one week

Our Services

1.    OEM/ODM services.

2.    Professional technical team.

3.    Offer Free technical support whenever you need.

4.    One year warranty and technical maintenance

 

 

Certifications

 

FAQ

Q1:Can I have a sample order?

A:Yes,we welcome sample order to test and check quality.

 

Q2:What is the lead time?

A:Sample needs 1-3 days, mass product according to your quantity.

 

Q3:How do you ship the goods and how long does it take arrive?

A:We usually ship by DHL,UPS,FedEX or by Air. 3-5 days after payment received.

 

Q4:Do you guarantee for the products?

A:Yes,we offer one year guarantee for the products.

 

Q5:Do you offer OEM service?

A:Yes,we can design the products according to your request.

 

 

2 Zone Fire alarm panel ,2 Zone Fire alarm panel ,2 Zone Fire alarm panel

询价单
total0items  Comments