Product Description
Features:
- Meanwell 1600W Power Supply
- Universal AC input / Full range (Withstand 300VAC surge input for 5 seconds)
- Built-in active PFC function
- High efficiency up to 93%
- Forced air cooling by built-in DC Fan
- Output voltage and constant current level programmable
- Active current sharing up to 9600w(5+1)
- Built-in remote ON-OFF control / remote sense / auxiliary power / DC OK signal / OTP alarm signal
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Optional PMBus protocol
- 5 years warranty
Applications:
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Aging facility
- Digital broadcasting
- Constant current source
- Redundant system
1600W Details:
MODEL | RSP-1600-12 | RSP-1600-24 | RSP-1600-27 | RSP-1600-36 | RSP-1600-48 | |
OUTPUT | DC VOLTAGE | 12V | 24V | 27V | 36V | 48V |
CURRENT RANGE | 125A | 67A | 59A | 44.5A | 33.5A | |
RATED CURRENT | 0 ~ 125A | 0 ~ 67A | 0 ~ 59A | 0 ~ 44.5A | 0 ~ 33.5A | |
RATED POWER | 1500W | 1608W | 1593W | 1602W | 1608W | |
RIPPLE & NOISE | 150mVp-p | 200mVp-p | 200mVp-p | 250mVp-p | 300mVp-p | |
VOLTAGE ADJ. RANGE | 11.5 ~ 15V | 23.5 ~ 30V | 26.5 ~ 33.5V | 35.5 ~ 45V | 47.5 ~ 58.8V | |
VOLTAGE TOLERANCE | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1500ms, 60ms/230VAC at full load | |||||
HOLD UP TIME | 16ms/230VAC at 75% load 10ms / 230VAC at full load | |||||
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | ||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||
POWER FACTOR | 0.95/230VAC at full load | |||||
EFFICIENCY | 89% | 91.5% | 92% | 92% | 93% | |
AC CURRENT | 14A/115VAC 8A/230VAC | 15A/115VAC 8.5A/230VAC | ||||
INRUSH CURRENT | COLD START 35A/230VAC | |||||
LEAKAGE CURRENT | <2.0mA / 230VAC | |||||
PROTECTION | OVER LOAD | 105 ~ 115% rated output power | ||||
Protection type :Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover | ||||||
OVER VOLTAGE | 15.75 ~ 18.75V | 31.5 ~ 37.5V | 35.2 ~ 41.9V | 47.2 ~ 56.3V | 63 ~ 75V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||||||
OVER TEMPERATURE | Protection type : Shut down o/p voltage, recovers automatically after temperature goes down | |||||
FUNCTION | OUTPUT VOLTAGE PROGRAMMABLE(PV) |
Adjustment of output voltage is allowable to 40 ~ 125% of nominal output voltage (60 ~ 125% for 12V). Please refer to the Function Manual. |
||||
CONSTANT CURRENT LEVEL PROGRAMMABLE(PC) | Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual. | |||||
AUXILIARY POWER | 5V @ 0.3A 12V @ 0.8A | |||||
REMOTE ON-OFF CONTROL | By electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the Function Manual | |||||
REMOTE SENSE | Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual | |||||
ALARM SIGNAL | Isolated signal output for T-alarm and DC OK | |||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70°C (Refer to "Derating Curve") | ||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||
STORAGE TEMP., HUMIDITY | -40 ~ +85°C, 10 ~ 95% RH | |||||
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C ) | |||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |||||
SAFETY & EMC | SAFETY STANDARDS | U60950-1, TUV EN60950-1 approved | ||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC | |||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | |||||
EMC EMISSION | Parameter | Standard | Test Level / Note | |||
Conducted | EN55022 (CISPR22) / EN55011 (CISPR11) | Class B | ||||
Radiated | EN55022 (CISPR22) / EN55011 (CISPR11) | Class A | ||||
Harmonic Current | EN61000-3-2 | Class A | ||||
Voltage Flicker | EN61000-3-3 | ----- | ||||
EMS IMMUNITY | EN55024 , EN61204-3, EN61000-6-2 | |||||
Parameter | Standard | Test Level / Note | ||||
ESD | EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | ||||
Radiated | EN61000-4-3 | Level 3 | ||||
EFT / Burst | EN61000-4-4 | Level 3 | ||||
Surge | EN61000-4-5 | Level 4, 1KV/Line-Line; 2KV/Line-Earth |
||||
Conducted | EN61000-4-6 | Level 3 | ||||
Magnetic Field | EN61000-4-8 | Level 4 | ||||
Voltage Dips and Interruptions | EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 peniods, | ||||
>95% interruptions 250 periods | ||||||
OTHERS | MTBF | 160.9K hrs min. Telcordia SR-332 (Bellcore) ; 42.1K hrs min. MIL-HDBK-217F (25°C) | ||||
DIMENSION | 300*85*41mm (L*W*H) | |||||
PACKING | 1.80Kg; 6pcs/11.8Kg/1.3CUFT |
Mechanical Specification:
Meanwell 1600W 12V 125A SMPS Power Supply RSP-1600-12
Packing
Packing:
Shipping:
Factory View
Strict, professional production and test, large stock for fast shipping.
Certifications
What Certification do we have?
Application
What our Power Supply can do for you?
More Products
If you are interested in other models, please hit below links for details....