Product Description
The GoodWe ES series bi-directional hybrid energy storage inverter is suitable for on-grid PV systems. It can also control the flow of energy intelligently. During the day, the PV plant generates electricity which can be provided to the loads, fed into the grid or charge the battery. The electricity stored can be released when the loads require it during the night. Additionally, the power grid can also charge the storage devices via the inverter.
Product Parameters
Datasheet | GW3648D-ES | GW5048D-ES | ||
Battery Input Data | Battery Type | Li-Ion | ||
Nominal Battery Voltage (V) | 48 | |||
Max. Charging Voltage (V) | ≤60 (Configurable) | |||
Max. Charging Current (A)*1 | 75 | 100 | ||
Max. Discharging Current (A)*1 | 75 | 100 | ||
Battery Capacity (Ah)*2 | 50~2000 | |||
Charging Strategy for Li-Ion Battery | Self-adaption to BMS | |||
PV String Input Data | Max. DC Input Power (W) | 4600 | 6500 | |
Max. DC Input Voltage (V) | 580 | |||
MPPT Range (V) | 125~550 | |||
Start-up Voltage (V) | 125 | |||
Min. Feed-in Voltage (V)*3 | 150 | |||
MPPT Range for Full Load (V) | 170~500 | 215~500 | ||
Nominal DC Input Voltage (V) | 360 | |||
Max. Input Current (A) | 11/11 | |||
Max. Short Current (A) | 13.8/13.8 | |||
No. of MPP Trackers | 2 | |||
No. of Strings per MPP Tracker | 1 | |||
AC Output Data(On-grid) | Nominal Apparent Power Output to Utility Grid (VA)*8 | 3680 | 4600 | |
Max. Apparent Power Output to Utility Grid (VA))*4*9 | 3680 | 5100 | ||
Max. Apparent Power from Utility Grid (VA) | 7360 | 9200 | ||
Nominal Output Voltage (V) | 230 | |||
Nominal Ouput Freqency (Hz) | 50/60 | |||
Max. AC Current Output to Utility Grid (A) | 16 | 24.5*5 | ||
Max. AC Current From Utility Grid (A) | 32 | 40 | ||
Output Power Factor | ~1(Adjustable from 0.8 leading to 0.8 lagging) | |||
Output THDi (@Nominal Output) | <3% | |||
AC Output Data(On-grid) | Max. Output Apparent Power (VA) | 3680 | 4600 | |
Peak Output Apparent Power (VA)*6 | 5520,10sec | 6900,10sec | ||
Max. Ouput Current (A) | 16 | 20 | ||
Nominal Output Voltage (V) | 230 (±2%) | |||
Nominal Ouput Frequency (Hz) | 50/60 (±0.2%) | |||
Output THDv (@Linear Load) | <3% | |||
Efficiency | Max. Efficiency | 97.60% | ||
Max. Battery to Load Efficiency | 94.00% | |||
European Efficiency | 97.00% | |||
Protection | Anti-Islanding Protection | Integrated | ||
PV String Input Reverse Polarity Protection | Integrated | |||
Insulation Resistor Detection | Integrated | |||
Residual Current Monitoring Unit | Integrated | |||
Output Over Current Protection | Integrated | |||
Output Short Protection | Integrated | |||
Output Over Voltage Protection | Integrated | |||
General Data | Operating Temperature Range (°C) | -25~60 | ||
Relative Humidity | 0~95% | |||
Operating Altitude (m) | ≤4000 | |||
Cooling | Natural Convection | |||
Noise (dB) | <25 | |||
User Interface | LED & APP | |||
Communication with BMS*7 | RS485; CAN | |||
Communication with Meter | RS485 | |||
Communicaiton with Portal | Wi-Fi | |||
Weight (kg) | 28 | 30 | ||
Size (Width*Height*Depth mm) | 516*440*184 | |||
Mounting | Wall Bracket | |||
Protection Degree | IP65 | |||
Standby Self Consumption (W) | <13 | |||
Topology | Battery Isolation |
*1 : The actual charge and discharge current also depends on the battery.
*2 : Under off-grid mode, then battery capacity should be more than 100Ah.
*3 : When there is no battery connected, inverter starts feeding in only if string voltage is higher than 200V.
*4 : 4600 for VDE 0126-1-1 &VDE-AR-N4105, 4950 for AS4777.2(GW5048D-ES), 4050 for CEI 0-21 (GW3648D-ES).
*5 : 21.7A for AS4777.2.
*2 : Under off-grid mode, then battery capacity should be more than 100Ah.
*3 : When there is no battery connected, inverter starts feeding in only if string voltage is higher than 200V.
*4 : 4600 for VDE 0126-1-1 &VDE-AR-N4105, 4950 for AS4777.2(GW5048D-ES), 4050 for CEI 0-21 (GW3648D-ES).
*5 : 21.7A for AS4777.2.
*6 : Can be reached only if PV and battery power are enough.
*7 : CAN communication is configured by default. If 485 communication is used, please
replace the corresponding communication line.
*8 : For Belgium Nominal Apparent Power Output to Utility Grid (VA): GW3648D-ES is 3600.
*9 : For Belgium Max. Output Apparent Power (VA): GW3648D-ES is 3600.
*7 : CAN communication is configured by default. If 485 communication is used, please
replace the corresponding communication line.
*8 : For Belgium Nominal Apparent Power Output to Utility Grid (VA): GW3648D-ES is 3600.
*9 : For Belgium Max. Output Apparent Power (VA): GW3648D-ES is 3600.
Projects
Packing&Shipping
Delivery & Payment Terms
T/T | EXW | 30%T/T in advance,paid the balance before shipment | |||||
FOB | |||||||
CFR(C&F) | 30%T/T in advance,paid the balance against copy of B/L | ||||||
CIF | |||||||
L/C | Optional L/C amount above 50,000usd, we can accept L/C at sight | ||||||
West Union | |||||||
paypal | |||||||
Delivery Time | 7~10days after receiving payment for one container |