Product Description
The Goodwe ET Series is a three-phase high voltage energy storage inverter that enables enhanced energy independence and maximizes self-consumption through an export limit feature and time of use shifts for reduced electric bills. Covering a power range of 5 kW, 6.5kW, 8 kW and 10 kW, the ET Series allows up to 10% overloading to maximize power output and features Uninterruptible Power Supply Function (UPS) to inductive loads such as air conditioners or refrigerators with an automatic switchover time of less than 10 milliseconds, providing savings when the grid is up and independence and security when it is down or compromised.
Product Parameters
Datasheet | GW5K-ET | GW6.5K-ET | GW8K-ET | GW10K-ET | ||||
Battery Input Data | Battery Type | Li-lon | ||||||
Battery Voltage Range(V) | 180~600 | |||||||
Max. Charging Current(A) | 25 | |||||||
Max. Discharging Current (A) | 25 | |||||||
Charging Strategy for Li-Ion Battery | Self-adaption to BMS | |||||||
PV String Input Data | Max. DC Input Power (W) | 6650 | 8450 | 9600 | 13300 | |||
Max. DC Input Voltage (V)*1 | 1000 | |||||||
MPPT Range (V)*2 | 200~850 | |||||||
Start-up Voltage (V) | 180 | |||||||
Min. Feed-in Voltage (V) | 210 | |||||||
MPPT Range for Full Load (V)*3 | 240~850 | 310-850 | 380~850 | 460~850 | ||||
Nominal DC Input Voltage (V)*4 | 620 | |||||||
Max. Input Current (A) | 12.5/12.5 | |||||||
Max. Short Current (A) | 15.2/15.2 | |||||||
No. of MPP Trackers | 2 | 2 | 2 | 2 | ||||
No. of Strings per MPP Tracker | 1/1 | |||||||
AC Output Data(On-grid) | Nominal Apparent Power Output to Utility Grid (VA) | 5000 | 6500 | 8000 | 10000 | |||
Max. Apparent Power Output to Utility Grid (VA)*5 *9 | 5500 | 7150 | 8800 | 11000 | ||||
Max. Apparent Power from Utility Grid (VA) | 10000 | 13000 | 15000 | 15000 | ||||
Nominal Output Voltage (V) | 400/380, 3L/N/PE | |||||||
Nominal Ouput Freqency (Hz) | 50/60 | |||||||
Max. AC Current Output to Utility Grid (A) | 8.5 | 10.8 | 13.5 | 16.5 | ||||
Max. AC Current From Utility Grid (A) | 15.2 | 19.7 | 22.7 | 22.7 | ||||
Output Power Factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) | |||||||
Output THDi (@Nominal Output) | <3% | |||||||
AC Output Data(On-grid) | Max. Output Apparent Power (VA) | 5000 | 6500 | 8000 | 10000 | |||
Peak Output Apparent Power (VA)*6 | 10000, 60sec | 13000, 60sec | 16000, 60sec | 16500, 60sec | ||||
Max. Ouput Current (A) | 8.5 | 10.8 | 13.5 | 16.5 | ||||
Nominal Output Voltage (V) | 400/380 | |||||||
Nominal Ouput Frequency (Hz) | 50/60 | |||||||
Output THDv (@Linear Load) | <3% | |||||||
Efficiency | Max. Efficiency | 98.0% | 98.0% | 98.2% | 98.2% | |||
Max. Battery to Load Efficiency | 97.5% | 97.5% | 97.5% | 97.5% | ||||
European Efficiency | 97.2% | 97.2% | 97.5% | 97.5% | ||||
Protection | Anti-Islanding Protection | Integrated | ||||||
PV String Input Reverse Polarity Protection | Integrated | |||||||
Insulation Resistor Detection | Integrated | |||||||
Residual Current Monitoring Unit | Integrated | |||||||
Output Over Current Protection | Integrated | |||||||
Output Short Protection | Integrated | |||||||
Battery Input Reverse Polarity Protection | Integrated | |||||||
Output Over Voltage Protection | Integrated | |||||||
General Data | Operating Temperature Range (°C) | -35~60 | ||||||
Relative Humidity | 0~95% | |||||||
Operating Altitude (m) | ≤4000 | |||||||
Cooling | Nature Convection | |||||||
Noise (dB) | <30 | |||||||
User Interface | LED & APP | |||||||
Communication with BMS*7 | RS485; CAN | |||||||
Communication with Meter | RS485 | |||||||
Communication with EMS | RS485 (Insulated) | |||||||
Communicaiton with Portal | Wi-Fi | |||||||
Weight (kg) | 24 | 24 | 25 | 25 | ||||
Size (Width*Height*Depth mm) | 415*516*180 | |||||||
Mounting | Wall Bracket | |||||||
Protection Degree | IP66 | |||||||
Standby Self Consumption (W)*8 | <15 | |||||||
Topology | Battery Non-Isolation |
*1 : For 1000V system, Maximum operating voltage is 950V.
For AustraliaL safety, there will be a warning if PV voltage > 600V.
*2 : For AustraliaL safety, MPPT range is 200~550V.
*3 : For AustraliaL safety, MPPT voltage upper limit is 550V.
*4 : For AustraliaL safety, nominal DC input voltage is 450V.
*5 : According to the local grid regulation.
For AustraliaL safety, there will be a warning if PV voltage > 600V.
*2 : For AustraliaL safety, MPPT range is 200~550V.
*3 : For AustraliaL safety, MPPT voltage upper limit is 550V.
*4 : For AustraliaL safety, nominal DC input voltage is 450V.
*5 : According to the local grid regulation.
*6 : Can be reached only if PV and battery power is enough.
*7 : CAN communication is configured by default. If 485 communication is used,
please replace the corresponding communication line.
*8 : No Back-up Output.
*9 : For Belgium Max. Output Apparent Power (VA): GW5K-ET is 5000; GW6.5K-ET is 6500; GW8K-ET is 8000; GW10K-ET is 10000.
*7 : CAN communication is configured by default. If 485 communication is used,
please replace the corresponding communication line.
*8 : No Back-up Output.
*9 : For Belgium Max. Output Apparent Power (VA): GW5K-ET is 5000; GW6.5K-ET is 6500; GW8K-ET is 8000; GW10K-ET is 10000.
Projects
Packing&Shipping
Delivery & Payment Terms
T/T | EXW | 30%T/T in advance,paid the balance before shipment | |||||
FOB | |||||||
CFR(C&F) | 30%T/T in advance,paid the balance against copy of B/L | ||||||
CIF | |||||||
L/C | Optional L/C amount above 50,000usd, we can accept L/C at sight | ||||||
West Union | |||||||
paypal | |||||||
Delivery Time | 7~10days after receiving payment for one container |