Homepage|Business Center|Save the Page|Get the App
普通会员

Lovsun Solar Energy Group Co., Ltd.

Product Category
  • No Category Yet
Search
 
Link
  • No links
Home > Products > Goodwe Inverter ET Series 5KW 6.5KW 8KW 10KW Three Phase Hybrid Solar Inverter
Goodwe Inverter ET Series 5KW 6.5KW 8KW 10KW Three Phase Hybrid Solar Inverter
Click on the image to view the original image
Product: views:4Goodwe Inverter ET Series 5KW 6.5KW 8KW 10KW Three Phase Hybrid Solar Inverter 
Unit Price: Negotiated
Min.Order:
Supply:
Delivery: Shipment within days since the date of payment
Valid until: Long Term
Updated on: 2021-12-28 12:06
  Negotiated
Product Details
Product Description
The Goodwe ET Series is a three-phase high voltage energy storage inverter that enables enhanced energy independence and maximizes self-consumption through an export limit feature and time of use shifts for reduced electric bills. Covering a power range of 5 kW, 6.5kW, 8 kW and 10 kW, the ET Series allows up to 10% overloading to maximize power output and features Uninterruptible Power Supply Function (UPS) to inductive loads such as air conditioners or refrigerators with an automatic switchover time of less than 10 milliseconds, providing savings when the grid is up and independence and security when it is down or compromised.
Product Parameters
Datasheet
GW5K-ET
GW6.5K-ET
GW8K-ET
GW10K-ET
Battery Input Data
Battery Type
Li-lon



Battery Voltage Range(V)
180~600



Max. Charging Current(A)
25



Max. Discharging Current (A)
25



Charging Strategy for Li-Ion Battery
Self-adaption to BMS



PV String Input Data
Max. DC Input Power (W)
6650
8450
9600
13300
Max. DC Input Voltage (V)*1
1000



MPPT Range (V)*2
200~850



Start-up Voltage (V)
180



Min. Feed-in Voltage (V)
210
MPPT Range for Full Load (V)*3
240~850
310-850
380~850
460~850
Nominal DC Input Voltage (V)*4
620



Max. Input Current (A)
12.5/12.5



Max. Short Current (A)
15.2/15.2



No. of MPP Trackers
2
2
2
2
No. of Strings per MPP Tracker
1/1



AC Output Data(On-grid)
Nominal Apparent Power Output to Utility Grid (VA)
5000
6500
8000
10000
Max. Apparent Power Output to Utility Grid (VA)*5 *9
5500
7150
8800
11000
Max. Apparent Power from Utility Grid (VA)
10000
13000
15000
15000
Nominal Output Voltage (V)
400/380, 3L/N/PE



Nominal Ouput Freqency (Hz)
50/60



Max. AC Current Output to Utility Grid (A)
8.5
10.8
13.5
16.5
Max. AC Current From Utility Grid (A)
15.2
19.7
22.7
22.7
Output Power Factor
~1 (Adjustable from 0.8 leading to 0.8 lagging)



Output THDi (@Nominal Output)
<3%



AC Output Data(On-grid)
Max. Output Apparent Power (VA)
5000
6500
8000
10000
Peak Output Apparent Power (VA)*6
10000, 60sec
13000, 60sec
16000, 60sec
16500, 60sec
Max. Ouput Current (A)
8.5
10.8
13.5
16.5
Nominal Output Voltage (V)
400/380



Nominal Ouput Frequency (Hz)
50/60



Output THDv (@Linear Load)
<3%



Efficiency
Max. Efficiency
98.0%
98.0%
98.2%
98.2%
Max. Battery to Load Efficiency
97.5%
97.5%
97.5%
97.5%
European Efficiency
97.2%
97.2%
97.5%
97.5%
Protection
Anti-Islanding Protection
Integrated



PV String Input Reverse Polarity Protection
Integrated



Insulation Resistor Detection
Integrated



Residual Current Monitoring Unit
Integrated



Output Over Current Protection
Integrated



Output Short Protection
Integrated



Battery Input Reverse Polarity Protection
Integrated



Output Over Voltage Protection
Integrated



General Data
Operating Temperature Range (°C)
-35~60



Relative Humidity
0~95%



Operating Altitude (m)
≤4000



Cooling
Nature Convection



Noise (dB)
<30



User Interface
LED & APP



Communication with BMS*7
RS485; CAN



Communication with Meter
RS485



Communication with EMS
RS485 (Insulated)



Communicaiton with Portal
Wi-Fi



Weight (kg)
24
24
25
25
Size (Width*Height*Depth mm)
415*516*180



Mounting
Wall Bracket



Protection Degree
IP66



Standby Self-Consumption (W)*8
<15



Topology
Battery Non-Isolation



*1 : For 1000V system, Maximum operating voltage is 950V.
For AustraliaL safety, there will be a warning if PV voltage > 600V.
*2 : For AustraliaL safety, MPPT range is 200~550V.
*3 : For AustraliaL safety, MPPT voltage upper limit is 550V.
*4 : For AustraliaL safety, nominal DC input voltage is 450V.
*5 : According to the local grid regulation.
*6 : Can be reached only if PV and battery power is enough.
*7 : CAN communication is configured by default. If 485 communication is used,
please replace the corresponding communication line.
*8 : No Back-up Output.
*9 : For Belgium Max. Output Apparent Power (VA): GW5K-ET is 5000; GW6.5K-ET is 6500; GW8K-ET is 8000; GW10K-ET is 10000.
Projects
Packing&Shipping
Delivery & Payment Terms





Payment Terms


T/T
EXW
30%T/T in advance,paid the balance before shipment
FOB
CFR(C&F)
30%T/T in advance,paid the balance against copy of B/L
CIF
L/C
Optional L/C amount above 50,000usd, we can accept L/C at sight
West Union

Optional for amount less than 5000usd
paypal
Delivery Time
7~10days after receiving payment for one container
询价单
total0items  Comments