Product Description
On Grid System
Specifications
Datasheet | MIN 5000TL-X | MIN 6000TL-X | ||
Input Data (DC) | ||||
Max. recommended PV power(for module STC) | 7000W | 8100W | ||
Max. DC voltage | 550V | 550V | ||
Start voltage | 100V | |||
Nominal voltage | 360V | |||
MPP voltage range | 80V-550V | |||
No. of MPP trackers | 2 | |||
No. of PV strings per MPP tracker | 1 | |||
Max. input current per MPP tracker | 13.5A * | |||
Max. short-circuit current per MPP tracker | 16.9A | |||
Output data (AC) | ||||
AC nominal power | 5000W | 6000W | ||
Max. AC apparent power | 5000VA | 6000VA | ||
Nominal AC voltage(range*) | 230V (180-280V) | |||
AC grid frequency(range*) | 50/60 Hz (45-55Hz/55-65 Hz) | |||
Max. output current | 22.7A | 27.2A | ||
Adjustable power factor | 0.8leading…0.8lagging | |||
THDi | <3% | |||
AC grid connection type | Single phase | |||
Efficiency | ||||
Max.efficiency | 98.40% | 98.40% | ||
European efficiency | 97.50% | 97.50% | ||
MPPT efficiency | 99.90% | |||
Protection Devices | ||||
DC reverse polarity protection | yes | |||
DC switch | yes | |||
AC/DC surge protection | Type III / Type II | |||
Insulation resistance monitoring | yes | |||
AC short-circuit protection | yes | |||
Ground fault monitoring | yes | |||
Grid monitoring | yes | |||
Anti-islanding protection | yes | |||
Residual-current monitoring unit | yes | |||
AFCI protection | Optional | |||
General Data | ||||
Dimensions (W / H / D) | 375/350/160mm | |||
Weight | 10.8kg | |||
Operating temperature range | –25°C ... +60°C | |||
Noise emission (typical) | ≤35 dB(A) | |||
Nighttime power consumption | < 1W | |||
Topology | Transformerless | |||
Cooling | Natural convection | |||
Protection degree | IP65 | |||
Relative humidity | 0-100% | |||
Altitude | 4000m | |||
DC connection | H4/MC4(Optional) | |||
AC connection | Connector | |||
Display | OLED+LED/WIFI+APP | |||
Interfaces: RS485 / USB/Wi-Fi/GPRS/ RF/LAN | Yes/Yes/Optional/Optional/Optional /Optional | |||
Warranty: 5 years / 10 years | Yes /Optional | |||
CE, IEC62109, VDE0126-1-1, AS4777, AS/NZS 3100, VDE-AR-N4105, CQC, IEC61683, IEC60068, IEC61727, IEC62116, INMETRO |
Global Projects
Pack&Shipping
Delivery & Payment Terms
T/T | EXW | 30%T/T in advance,paid the balance before shipment | |||||
FOB | |||||||
CFR(C&F) | 30%T/T in advance,paid the balance against copy of B/L | ||||||
CIF | |||||||
L/C | Optional L/C amount above 50,000usd, we can accept L/C at sight | ||||||
West Union | |||||||
paypal | |||||||
Delivery Time | 7~10 days after receiving payment for one container |
Welcome to Alibaba Insurance Order
Guarantee of making shipment
Safety of your down payment before the shipment
Guarantee for after sale service for any issues
Inspection service from the third party is optional