- Place of Origin:
- Shandong, China
- Brand Name:
- LH
- Model Number:
- 660
- Max range:
- 200mm
- Max allowed error:
- ±2(mm)
- Name:
- steel bar diameter detector
- Mini measurement detection:
- 35mm
- Weight:
- 2kg
- size:
- 230*110*120
- Supply Ability:
- 2500 Set/Sets per Month steel bar diameter detector
- Packaging Details
- regular packaging
- Port
- qingdao/dalian/shenzhen/ningbo
- Lead Time:
Quantity(Sets) 1 - 5 >5 Est. Time(days) 5 To be negotiated
Concrete wall rebar detector , steel bar diameter detector
Features:
1.Uniprobe with two detect range: the uniprobe has both a small and large detect range;
2.Detect closely located bars: can detect closely situated, parallel bars with 1.5 diameter gap;
3.Actual distributing map of bars: Can out put the actual distributing map of bars after several times scanning;
4.Transverse Section Bars Distributing Map: Can output the transverse section map of bars distributing;
5.Test data may be transferred to computer via USB port, allowing real time analysis of data;
6.Rechargeable lithium battery; convenient, value for money, and environmentally friendly.
Reinforcement Detector Application:
1. Testing concrete cover thickness.
2. Test concrete member internal reinforcement position, rebar spacing, reinforcement position distribution.
3. Estimation bar diameter.
4. Detection of Cable and Plumbing pipe.
5. Detection of steel corrosion extent.
Reinforcement Detector parameter:
Technical Specifications of Rebar Locator | ||
Bar diameter application range | Φ6-50mm | |
Maximum permissible error of bar diameter | ≤+-1 | |
Cover thickness measuring range | ||
The first measuring range | 6-90mm | |
The second measuring range | 7-180mm | |
The maximum error of cover thickness | ||
The first measuring range | The second measuring range | |
6-59mm | 7-79mm | ≤+-1 |
60-69mm | 80-119mm | ≤+-2 |
70-90mm | 120-180mm | ≤+-4 |
Work temperature ℃ | -10-+40 | |
Relative humidity RH | <90% | |
Power supply | Alkaline cell X6 |
Specifications of Rebar Corrosion System | |
Measuring Potential | +-1000mV |
Test accuracy | +-1mV |
Measuring space | 1-99 cm(adjustable) |
Ambient Temperature | -10℃~+40℃ |
Environment Requirement | To avoid direct exposure to the sun for a long time |
Relative Humidity | <90%RH |
Electromagnetic Interference | No strong alternating electromagnetic field |
Distance of test point | 0-1000mm |
Available capacity | 50000 test point 5000 test areas |
Reinforcement Detector pictures:
Wechat: luhengMISS
Skype : luhengMISS
WhatApp:+8613625377838
QQ: 2853024687
Phone Number: +8613625377838