- Type:
- Immunoassay System
- Brand Name:
- BIOBASE
- Model Number:
- BIOBASE2000
- Place of Origin:
- Shandong, China
- Instrument classification:
- Class I
- Sample racks:
- 60 or 80 ~12 mm sample tubes or 40 - 16 mm sample tubes
- Dilution rack:
- 92 positions
- Microtiter plates:
- 2 plates (96 wells) with incubation capability
- Dispensing system:
- 1 aspirating-dispensing probe with X-Y-Z movement
- Washing system:
- two 8 nozzle on line manifolds
- Washing Residual volume:
- < 3μl
- Washing inaccuracy:
- CV < 5 % with 300 μl
- Readingsystem:
- 8 independent photometric channels
- Optical filters:
- 2 filters (450 and 630 nm)
- Power Supply:
- 200/110 VAC, 50-60 Hz
- Supply Ability:
- 100 Unit/Units per Month
- Packaging Details
- wooden package
- Port
- Qingdao
BIOBASE2000 Professional Medical Reader Fully automated ELISA analyzer price
Biobase2000 is fully automatic Four-Microplate ELISA system, capable of sampling, incubation, washing and data processing.
It is complete solution for your IVD ELISA assays. The syetem combines a high precision pipetting unit with stable incubators and efficiency washers and photometer unit.
1 Robotic hand.
2 Pipetting probe, 1ul stepping (1000ul volumes).
Total 25 racks, arbitrary rack can be defined as sample or reagent on the software.
4 units 96 well microplates (pipetting,incubator,reading).
1 unit independent washer &reader( two 8 nozzle manifolds).
Our Services
Model | BIOBASE2000 | |
Sample pipetting unit | Sample rack | 24 sample tubes/rack, at most 25 racks |
Primary sample tubes | 11.5-13mm | |
Pipetting | 8ul~1000ul, (10ul) CV<5% | |
Time to dispense | 15 minutes (typical)^100ul of 96 samples to plate from sample tubes or dilution tubes. | |
Dispensing system | 1 aspirating-dispensing probe with X-Y-Z movement;dilution system with a syringe of 1000ul, continuous flow washing station. | |
Reagent pipetting unit | Reagent racks | 2 reagent tanks(60ml)/ rack, at most 25 racks |
QC racks | 24 positions/QC rack, at most 25 racks | |
Pipetting | 8ul~1000ul,1ul stepping, | |
pipetting precision | (100ul )CV≤0.5% | |
Time to dispense | 2 minutes(typical)^100ul of 96 reagents to plate from reagent bottle | |
Washing unit | Programmable | Yes(options & parameters) |
Wash containers | 4 wash buffers at 2.0L, with level-sensing | |
Waste containers | 10L with waste full sensor | |
Washing system | two 8 nozzle manifolds, one to dispense and the other one to aspirate; | |
Washing residual | <2μl | |
Reading unit | Reading system | 8 independent photometric channels with mono and bichromatic reading capability |
Photometric range | 0.000 ~3.000 OD | |
Spectral range | 400-700nm | |
Optical filters | 2 precision filters (450and 630nm); 2 more on request (4 filters max, 405 nm, 450 nm, 492 nm and 630 nm) | |
Reading inaccuracy | inaccuracy±1% from 0.000 to 1.500 OD, ±2% from 1.500 to 3.000 OD | |
Incubation unit | Incubators | 4 independent units |
Programmable | Yes | |
Temperature range | RT to 45 °C | |
Temperature accuracy | ±0.5℃ | |
Temperature staility | ±0.5℃ | |
Software unit | Software system | Windows XP or Windows 7 or above, LIS system available, realize two-way data communications |
Function application | work list set up, patient reports and result filing; calibration curve ,storage for each carried out test | |
Data reduction | cut-off (qualitative) | |
Physical Specification | Power Supply | AC220V+ 10%,50/60Hz,450W |
Instrument Dimension | 110*72*70cm (L*W*H) | |
Instrument Weight | 100kg | |
Package Dimension | 138*91*98cm(L*W*H) | |
Total Weight | 150kg |