- Type:
- Microwave Therapy Equipments
- Brand Name:
- biobase
- Model Number:
- BK series
- Place of Origin:
- Shandong, China
- Instrument classification:
- Class II
- Wavelength Range:
- 190-1100nm
- Spectral Bandwidth:
- 1.8nm (2nm)
- Wavelength Accuracy:
- ± 0.3nm
- Wavelength Repeatability:
- ≤ 0.2nm(0.3)
- Photometric Accuracy:
- ± 0.002A (0-0.5Abs), ± 0.004A (0.5-1.0Abs), ± 0.5% T (0-100% T)
- Stray Light:
- ≤ 0.03 T @ 360nm; 220nm(0.04)
- Stability:
- ± 0.0003A / h @ 500nm
- Baseline Flatness:
- ± 0.0005A
- Noise:
- ± 0.0002Abs
- Optical System:
- Double Beam, Grating 1200 lines/mm
- Supply Ability:
- 5000 Set/Sets per Month
- Packaging Details
- fumigation wooden package
- Port
- Qingdao or others
- Picture Example:
- Lead Time:
Quantity(Sets) 1 - 1 >1 Est. Time(days) 10 To be negotiated
Biobase UV/Vis Spectrophotometer for sale
Features
Large LCD screen(480*272 Dots) with 65 thousand true color and support U disk data saving
Imported & Environmental Deuterium lamp, preventing from Ozone inhalation
Data output: Data can be exported to U disk (USB Output)
Print port: Instrument can connect PCL printer for printing A4 paper (USB Port)
Adopted high-class grating with wholly hermetic light path design, to ensure the instrument has the super low stray light
Real-time monitoring the lifetime of Deuterium lamp and Tungsten lamp with advanced system
Pre-aligned design ensures the user can change lamps conveniently
With GLP self-check function, check the wavelength accuracy and Photometry accuracy, can provide test report and power-off protection
Wavelength calibration, wavelength setting, change lamp source and dark current calibration automatically
With Si02 coating optical mirror, reducing the pollution from outside fully
Optional PC Software to expand the applications to Quantitative, Multi-Wavelength and Kinetics, Spectrum Scanning, DNA/Protein test
Basic Functions:
1. Photometry
Test Abs., Transmittance and Energy by fixed wavelength
2.Quantitative
Linear fit and Linear fit through zero two mode
a. Coefficient, Standard Sample input and Standard Sample read three
modes to establish standard curve
b. Establish A=K1*C+K0, can search original data, graph curve,
parameters settings
c. Can save 240 group curves, can test 240 data in each curve
d. Double wavelength, Triple wavelength test functions
3.Kinetics
Used for time course scanning or reaction ratecalculations A/t,can search all data.
4.Multi-Wavelength
Can test Transmittance and Abs. with 8 different wavelengths at most
5.Scanning User can set the scan range from 190nm to 1100nm to test the max. Abs. peak value, can do derivation, arithmetical operations to the graph.
6. Biology
6 methods: DNA/Protein, UV, Lowry, BCA,CBB and Biuret
Specification:
Model | BK-D560 | BK-D580 | BK-D590 | |
Optical System | Double Beam, Grating 1200 lines/mm | |||
Wavelength Range | 190-1100nm | |||
Wavelength Range | 1.8nm | 1nm | 0.5,1,2,4,5nm | |
Wavelength Accuracy | ± 0.3nm | |||
Wavelength Repeatability | ≤ 0.2nm | |||
Photometric Accuracy | ± 0.002A (0-0.5Abs), ± 0.004A (0.5-1.0Abs), ± 0.3% T (0-100% T) (0.3, 0.003) | |||
Photometric Repeatability | 0.001Abs (0-0.5Abs), 0.002Abs (0.5-1.0Abs), ≤ 0.2% T (0-100% T) | |||
Stray Light | ≤ 0.03 T @ 360nm; 220nm(0.04) | |||
Stability | ± 0.0003A / h @ 500nm | |||
Baseline Flatness | ± 0.0005A | |||
Noise | ± 0.0002Abs | |||
Display | 65 thousand true color 7 inch TFT LCD(480 *800) | |||
Photometric Mode | T, A, C, E | |||
Photometric Range | 0-200% T,-0.301-3.0A | |||
Detector | Silicon Photodiode | |||
Light Source | Deuterium Lamp, Tungsten Lamp | |||
Input | Membrane Keypad | |||
Output | USB2.0*2 Print and data output USB1.0 Connect PC | |||
Compartment | Optional 8 Auto Cell holder, Solid Sample Holder, Micro Cell Holder, 10-100mm Cell Holder |
Our service :
Pre-sale service:
24hours online to ensure quick response to customers" inquiry or online message;
Guide customers to choose the best suitable machine model;
Offer detailed specification and competitive prices;
Contract execution:
Machine production will be arranged strictly according to the contract;
Machine photos will be sent to you for inspection during production;
Update latest news after delivery and prepare customs clearance;
After-sale service:
Broken spare parts (except for wear parts) will be sent for free due to quality problems;
In time response to customers technical problems;
New products update for customers" reference.