- Place of Origin:
- Shandong, China
- Brand Name:
- BIOBASE
- Model Number:
- BK-UV1900
- Size:
- 620*500*370
- Weight:
- 18
- Focal Length:
- Spectrophotometer
- Wavelength Range:
- 190-1100nm, 190-1100nm
- Measurement Range:
- 0.02-2.5
- Spectral Bandwidth:
- 2nm 1nm 0.5,1,2,4,5nm
- Wavelength Accuracy:
- ± 0.5nm
- Wavelength Repeatability:
- ≤ 0.2nm(0.3)
- Photometric Accuracy:
- ± 0.002A (0-0.5Abs)
- Stray Light:
- ≤ 0.04% T @ 360nm; 220nm (0.05)
- Power:
- 110V/220±10% ,60/50Hz
- Supply Ability:
- 400 Unit/Units per Month
- Packaging Details
- wooden box
- Port
- Qingdao
- Lead Time:
Quantity(Units) 1 - 1 >1 Est. Time(days) 10 To be negotiated
Lab Analysis Instrument Infrared Spectrophotometer
BIOBASE LAB and Medical Equipment supplier
Product Description:
Features:
1.Large LCD screen(480*272 Dots) with 65 thousand true color and support U disk data saving
2.Imported & Environmental Deuterium lamp, preventing from Ozone inhalation
3. Data output: Data can be exported to U disk (USB Output)
4. Print port: Instrument can connect PCL printer for printing A4 paper (USB Port)
5.Adopted highclass grating with wholly hermetic light path design, to ensure the instrument has the super
low stray light
6.Real-time monitoring the lifetime of Deuterium lamp and Tungsten lamp with advanced system
7.Pre-aligned design ensures the user can change lamps conveniently
8.With GLP selfcheck function, check the wavelength accuracy and Photometry accuracy, can provide test
report and power-off protection
9.Wavelength calibration, wavelength setting, change lamp source and dark current calibration automatically
10.With Si02 coating optical mirror, reducing the pollution from outside fully
11.Optional PC Software to expand the applications to Quantitative, Multi-Wavelength and Kinetics, Spectrum Scanning, DNA/Protein test
Basic Functions:
1, Photometry
Test Abs., Transmittance and Energy by fixed wavelength
2, Quantitative
Linear fit and Linear fit through zero two modes
a. Coefficient, Standard Sample input and Standard Sample read three
modes to establish standard curve
b. Establish A=K1*C+K0, can search original data, graph curve,
parameters settings
c. Can save 240 group curves, can test 240 data in each curve
d. Double wavelength, Triple wavelength test functions
3, Kinetics
Used for time course scanning or reaction ratecalculations A/t,
can search all data.
4, Multi-Wavelength
Can test Transmittance and Abs. with 8 different wavelengths at
most
5, Scanning
User can set the scan range from 190nm to 1100nm to
test the max. Abs. peak value, can do derivation,
arithmetical operations to the graph.
6, Biology
6 methods: DNA/Protein, UV, Lowry, BCA,CBB and Biuret
Technical Parameters:
Model | BK-UV1900 BK-UV1900PC | BK-V1900 BK-V1900PC | |
Optical System | Single Beam, Grating 1200 lines/mm | ||
Wavelength Range | 190-1100nm | 320-1100nm | |
Spectral Bandwidth | 2nm 1nm 0.5,1,2,4,5nm | ||
Wavelength Accuracy | ± 0.5nm | ||
Wavelength Repeatability | ≤ 0.3nm | ||
Photometric Accuracy | ± 0.002A (0-0.5Abs), ± 0.004A (0.5-1.0Abs), ± 0.5% T (0-100% T) | ||
Photometric Repeatability | 0.001Abs (0-0.5Abs), 0.002Abs (0.5-1.0Abs), ≤ 0.2% T (0-100% T) | ||
Stray Light | ≤ 0.05% T @ 360nm; 220nm | ||
Stability | ± 0.0008A / h @ 500nm | ||
Baseline Flatness | ± 0.002A | ||
Noise | 0.0005Abs @ 500nm | ||
Display | 480 *272 65 thousand true color TFT LCD | ||
Photometric Mode | T, A, C, E | ||
Photometric Range | 0-200% T,-0.301~3.0A | ||
Detector | Silicon Photodiode | ||
Light Source | Deuterium Lamp, Tungsten Lamp | ||
Input | Membrane Keypad | ||
Output | USB2.0*2 Print and data output USB1.0 Connect PC | ||
Standard Accessories | 10mm glass cuvette *4 units 10mm quartz cuvette *2 units | 10mm glass uvette *4 units | |
Optional Accessories | Single cell holder,General cell holder,Test tube holder,Solid sample holder,Deuterium lamp,Halogen lamp,4-place Cell holder,Printer,Water-jacketedcell holder,Reflection accessory 5°,Auto 8-cell changer,Micro cell holder,Water-jacketed cell holder,Constant-temperature system | ||
Power Supply | AC110V/220±10% ,60/50Hz | ||
Packing Size(mm) | 620*500*370 | 620*500*370 | |
Gross Weight(kg) | 18 | 16.5 |
Many shipping methods available
--by sea
--by air
--by express delivery, inclucing DHL, TNT, FedDex
Copamany show |
BIOBASE group, founded in 1999 and been through high and stable development for 15 years, who is now with revenues of one hundred million, 1200 employees in China and abroad offices, 22.4 acres land industry parks and 20000 square meters production base.
Our mainproducts : |
Hot Sale: |
BIOBASE Certificates:
Biobase is the sole manufacturer in China recognized by American NSF49 and EN12469. Also certified by ISO9001, ISO14001, ISO13485,CE, MET, FDA
Exhibition:
Our Service: |
Worldwide service
- Biobase India Branch Office
- Found in September, 2014, in Banglaore city, India
- BIOBASE warehouse in Jordan
- BIOBASE Business Incubator
- Found in 25th , July 2016 at Silicon Valley, California, USA
- BIOBASE Germany Branch Office (Under construction)
After-Sales Service
- 1-year warranty period.
- Training how to install the machine, training how to use the machine
- Engineers available to service machinery overseas.
- Reliable quality and thoughtful after sale service.
Any inquiry feel free to contact me
vivian
Mobile: 187 5312 7139
Tel: +86-0531-66777785
Add: No.51 South Gongye Road,Jinan,China.