Home > Products > BK-AA4530F Type Cheap Price Atomic Absorption Spectrophotometer for Sale
BK-AA4530F Type Cheap Price Atomic Absorption Spectrophotometer for Sale
Click on the image to view the original image
Product: views:3BK-AA4530F Type Cheap Price Atomic Absorption Spectrophotometer for Sale 
Branch: BIOBASE
Unit Price: Negotiated
Min.Order:
Supply:
Delivery: Shipment within days since the date of payment
Valid until: Long Term
Updated on: 2019-12-03 18:42
  Negotiated
Product Details
Overview
Quick Details
Place of Origin:
Shandong, China
Brand Name:
BIOBASE
Model Number:
BK-AA4530F
Size:
850 x 700 x 750 MM (Main instrument)
Weight:
105Kg(Main instrument)
Focal Length:
1.8nm
Wavelength Range:
190-900nm, 190-900nm
Measurement Range:
190-1100nm
Wavelength Accuracy:
± 0.15nm
Wavelength Repeatability:
≤0.04nm
Consumption:
7000W
Power Supply:
220V, 50Hz
Supply Ability
Supply Ability:
1000 Unit/Units per Month
Packaging & Delivery
Packaging Details
Wooden package
Port
Qingdao/Shanghai/Guangzhou
Lead Time:
Shipped in 7 days after payment

Cheap Price Atomic Absorption Spectrophotometer BK-AA4530F Type for Sale

Product Description

Features of Atomic Absorption spectrophotometers BK-AA4530F

1. Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).

2. Integrated floated optical platform design improves the optical system shock resistance stable. 

3. Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.

4. Position adjusting: the flame burner can be set on the best position automatically.

5. Fully automated wavelength scanning and peak searching.

6. Complete safety chains protection equipment: warning and automatic safety protection for the wrong burner connection, leakage of the gas, under voltage of air and the abnormal flameout.

7. Deuterium lamp and self-absorption background calibration.

8. Measuring method: flame absorption method and emission method.

9. Result printing: parameter, data result and diagram.

10. Data processing: more than 500 data self-storage and cut-off storage, the analyzed result is stored in EXCEL format.

 

Specifications of Atomic Absorption spectrophotometers BK-AA4530F

 

Model

BK-AA4530F

Wavelength Range

190 – 900nm

Wavelength Accuracy

±0.15nm

Wavelength Receptivity

≤0.04nm

Base Line Stability

≤0.002A/30min (Cu)

Characteristic Concentration 

0.02μg/ml/1% (Cu)

Detection Limit

0.004μg/ml (Cu)

Measurement Repeatability

≤0.5%

Grating

1800 lines/mm

Inflamer

All-metal titanium burner

Atomizer

Efficient glass atomizer

Lamp stand

8

D2 background Calibration

When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method

Power Supply

220V, 50/60Hz

Packing Size(mm)

850 x 700 x 750(Main instrument)

950 x 620 x 1020( Accessories )

Gross Weight(kg)

105Kg  (Main instrument)

100Kg   ( Accessories )

 

Standard Accessories of Atomic Absorption spectrophotometers BK-AA4530F

PC workstation

HP inkjet printer 

Oil free Air compressor

Acetylene reducing valve

Cu Hollow cathode lamp

Air filter

Optional Accessories of Atomic Absorption spectrophotometers BK-AA4530F

Graphite Furnace

Hollow cathode lamp(Ag, Au, Ba, Ca, Cd, Cr ,Fe, Hg ,K, Li, Mg,Mn, Na, Ni, Pb, Zn, Sb,etc)

 

FLAME SYSTEM:

Acetylene Air Burner

100mm

Ignition Dynamic Baseline Drift

≤0.006A/30min

Characteristic Concentration

≤0.025μg/ml/1%(Cu)

Related Standard Deviation of the Accuracy

 

≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)

Safety system

Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.

 

GRAPHITE FURNACE(Optional):

Max. temperature

3000℃

Max Heating Speed

≥2000℃/S

Characteristic Quantity

Cd≤0.5×10-12g  Cu≤0.5×10-11g

Accuracy

Cu≤3% Cd≤3%

Safety system

Over current protection Low air pressure alarm / protection

Low cooling water flow alarm/protection

Power Supply

220V, 50Hz  

Consumption

7000W

Packing Size(mm)

550*450*300

Gross Weight(kg)

65

Production Line

 

 

BIOBASE Information

BIOBASE GROUP

Established in 1999

1200 employees in China and abroad offices.

 

Leading professional manufacturer of laboratory and medical products.
Specializing in: 
*air protection products
*cold chain products
*analytical instruments
*most of lab and medical products
*laboratory furniture,laboratory and  clean room construction
Also provides professional solutions for clean projects.
One-stop service from design, production, installation, commissioning, inspection-acceptance of clean operating room, ICU, P2/PCR/HIV Laboratories, purification engineering, etc.

 

Our mission is to enable our customers to make the world healthier,cleanerand safer.

BIOBASE group,serving global distributors and its loyal end users, is becoming one of the most 

important scientific services supplier.

Add: NO.51 South Gongye Road, Jinan250101, Shandong, China.

Website: www.biobase.cc  www.meihuatrade.com    www.labproject.cn

 

BIOBASE Certificates

 

 

BIOBASE Exhibition

Sincerely invite you to visit our booth, and hope to talk with you face by face.

 

FAQ

 

Contact

 

Welcome to BIOBASE

Contact: Tessie

Skype: tessie.biobase

E-mail: sales44@ biobase.cc

询价单
total0items  Comments