- Place of Origin:
- Shandong, China
- Brand Name:
- biobase
- Model Number:
- BK-D560
- Size:
- based on model
- Weight:
- 12kg
- Focal Length:
- Bandwidth 1.8nm; 1nm 0.5,1,2,4,5nm
- Wavelength Range:
- 1.8nm; 1nm; 0.5,1,2,4,5nm Spectral Bandwidth, 190-1100nm
- Measurement Range:
- 190-1100nm double beam
- Model:
- BK-D560
- Optical System:
- Double Beam, Grating 1200 lines/mm
- Display:
- 65 thousand true color 7 inch TFT LCD(480 *800)
- Photometric Mode:
- T, A, C, E
- Detector:
- Silicon Photodiode
- Light Source:
- Deuterium Lamp, Tungsten Lamp
- Input:
- Membrane Keypad
- Output:
- USB2.0*2 Print and data outputUSB1.0 Connect PC
- Supply Ability:
- 500 Set/Sets per Month
- Packaging Details
- wooden box
- Port
- qingdao
- Lead Time:
- 10 days
BK-D560/BK-D580/BK-D590 Double beam scanning UV/VIS spectrophotometer,Nano drop for Multi-Wavelength
1. Picture of scanning UV/VIS spectrophotometer,Nano drop for Multi-Wavelength
2. Accessory of scanning UV/VIS spectrophotometer,Nano drop for Multi-Wavelength
3. Main types of spectrometer
4. Features of scanning UV/VIS spectrophotometer,Nano drop for Multi-Wavelength
1.Environmental Deuterium lamp, preventing from Ozone inhalation
2.Real-time monitoring the lifetime of Deuterium lamp and Tungsten lamp
3.Socket-Type Deuterium lamp and Tungsten lamp
4.GLP self-check function:check the wavelength accuracy and Photometry accuracy,provide test report and power-off protection
5.Wavelength calibration, wavelength setting, change lamp source and dark current calibration automatically
6.Si02 coating optical mirror, reduces the influence from outside
Basic Functions:
1, Photometry
Test Abs., Transmittance and Energy by fixed wavelength
2, Quantitative
Linear fit and Linear fit through zero two modes
a.Coefficient, Standard Sample input and Standard Sample read three modes to establish standard curve
b. Establish A=K1*C+K0, can search original data, graph curve, parameters settings
c. Can save 240 group curves, can test 240 data in each curve
d. Double wavelength, Triple wavelength test functions.
3, Kinetics
Used for time course scanning or reaction rate calculations A/t, can search all data
4, Multi-Wavelength
Can test Transmittance and Abs. with 8 different wavelengths at most
5, Scanning
User can set the scan range from 190nm to 1100nm to test the max. Abs. peak value, can do derivation,arithmetical operationsto the graph.
6, Biology
6 methods: DNA/Protein, UV, Lowry, BCA,CBB and Biuret
s: DNA/Protein, UV, Lowry, BCA,CBB
and Biuret
5. Technical parameter of scanning UV/VIS spectrophotometer,Nano drop for Multi-Wavelength
Model | BK-D560 | BK-D580 | BK-D590 |
Optical System | Double Beam, Grating 1200 lines/mm | ||
Wavelength Range | 190-1100nm | ||
Wavelength Range | 1.8nm | 1nm | 0.5,1,2,4,5nm |
Wavelength Accuracy | ± 0.3nm | ||
Wavelength Repeatability | ≤ 0.2nm | ||
Photometric Accuracy | ± 0.002A (0-0.5Abs), ± 0.004A (0.5-1.0Abs), ± 0.3% T (0-100% T) | ||
Photometric Repeatability | 0.001Abs (0-0.5Abs), 0.002Abs (0.5-1.0Abs), ≤ 0.2% T (0-100% T) | ||
Stray Light | ≤ 0.05 T @ 360nm; 220nm | ||
Stability | ± 0.0008A / h @ 500nm | ||
Baseline Flatness | ± 0.0005A | ||
Noise | ± 0.0002Abs | ||
Display | 65 thousand true color 7 inch TFT LCD(480 *800) | ||
Photometric Mode | T, A, C, E | ||
Photometric Range | 0-200% T,-0.301-3.0A | ||
Detector | Silicon Photodiode | ||
Light Source | Deuterium Lamp, Tungsten Lamp | ||
Input | Membrane Keypad | ||
Output | USB Print and data output, Connect PC | ||
Standard Accessories | 10mm glass cuvette *4 units 10mm quartz cuvette *2 units,software | ||
Optional Accessories | Single cell holder,General cell holder,Test tube holder,Solid sample holder,Deuterium lamp,Halogen lamp,4-place Cell holder,Printer,Water-jacketedcell holder,Reflection accessory 5°,Auto 8-cell changer,Micro cell holder,Water-jacketed cell holder,Constant-temperature system
| ||
Power Supply | AC110V/220±10% ,60/50Hz | ||
Packing Size(mm) | 740*570*440 | ||
Gross Weight(kg) | 25 |
With a wooden or carton boxes, strong packing, Ocean shipping,air transport or express courier service is available.
Our principle is to provide our perfect service to you.
our target goal is to offer you our excellent service.
With the sustained business conception of “credit is the basis, quality is the first”, we gain the high trust from customers.
BIOBASE group, founded in 1999 and been through high and stable development for 15 years, who is now with revenues of one hundred million, 1200 employees in China and abroad offices, 22.4 acres land industry parks and 20000 square meters production base.
The products we manufacture extends to most of the laboratory items and scientific analytical equipments. Our mission is to enable our customers to make the world healthier, cleaner and safer.
BIOBASE group invests in science and technology research, aim to keep impoving products performance and quality as well as develop new products to meet customers wide requirement.
We satisfy our customers by offering comprehensive support, purchase convenience and we are ready to serves more and more BIOBASE users.
BIOBASE group, serving global distributors and its loyal end users, is becoming one of the most important scientific services supplier.
Till now we have exported to more than 200 countries.
Exhibition
Any question or help,please feel free to contact with me at any time!
Contact :Psyche
Skype:psyche_lxf
Wechat:2048393499 ; Email:sales57 @biobase.cc
Whatsapp:+86 15853187153
Tel number:86-531-82373113
WELCOME TO CLICK AND INQUIRY.