- Place of Origin:
- China
- Brand Name:
- BIOBASE
- Model Number:
- BK-AA320N
- Size:
- 1250 x 800 x 750
- Weight:
- 200kg
- Focal Length:
- 190-900nm
- Wavelength Range:
- 190-900nm*, 190-900nm
- Measurement Range:
- 0.2nm, 0.4nm,etc
- Spectral Bandwidth:
- 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
- Optical System:
- 40%
- Wavelength Repeatability ≤:
- 0.3nm (single direction)
- Wavelength Accuracy:
- ±0.5nm
- Base Line Stability:
- ±0.004Abs/30min
- Characteristic Concentration:
- ≤ 0.04μg/ml/1% (Cu)
- Detection Limit:
- ≤0.008μg/ml (Cu)
- Background Calibration:
- >30 times
- Supply Ability:
- 1000 Unit/Units per Month
- Packaging Details
- wooden box
- Port
- qingdao
BK-AA320N Atomic Absorption Spectrophotometer/flame atomic absorption spectrophotometer/AAS with factory price
1, picture of BK-AA320N Atomic Absorption Spectrophotometer
2. Technical Parameter of BK-AA30N 2Atomic Absorption Spectrophotometer
Model | BK-AA320N |
Wavelength Range | 190-900nm |
Wavelength Accuracy | ±0.5nm |
Wavelength Repeatability | ≤ 0.3nm (single direction) |
Spectral Bandwidth | 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm |
Resolution | <40% |
Base Line Stability | ±0.004Abs/30min |
Characteristic Concentration | ≤ 0.04μg/ml/1% (Cu) |
Detection Limit | ≤0.008μg/ml (Cu) |
Background Calibration | >30 times |
Power Supply | 220V, 50/60Hz |
Packing Size(mm) | 1250 x 800 x 750 (Main instrument) 550 x 460 x 1350 ( Accessories ) |
Gross Weight(kg) | 150Kg (Main instrument) 50Kg ( Accessories ) |
Standard Accessories | RS232 serial port Oil-free air compressor Glass Atomizer Cu Hollow cathode lamp Atomizer unit, Burner unit ,Dust cover Water-separating gas filter Titanium burner---10cm
|
Optional Accessories | Printer Model GA3202 HGA graphite furnace system Hydride generator Graphite tubes Software Recirculating cooling water system Hollow cathode lamp(Ag, Au, Ba, Ca, Cd, Cr ,Fe, Hg ,K, Li, Mg,Mn, Na, Ni, Pb, Zn, Sb,etc) |
3. Feature of BK-AA30N 2Atomic Absorption Spectrophotometer
1. Build-in computer data processing and LCD display.
2. Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature and electronic circuit drift.
3. Quickly: The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately.
4. High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.
5. High energy optical path.
6. Long-life and anti-corrosive atomization system.
7. Multi-functional analysis mode: flame absorption;flame emission;graphite furnace atomic absorption ; hydride generation.
8. Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach more than 60.
Every year we attend lots of international exhibitions, so we can meet at the exhibitions. Also you"re highly welcomed to our company and factory.
With a wooden or carton boxes, strong packing, Ocean shipping,air transport or express courier service is available.
If you are interested in our products,welcome to send inquiry to me~