Home > Products > BK-S360 with PC Analysis Software Scanning UV/VIS Spectrophotometer
BK-S360 with PC Analysis Software Scanning UV/VIS Spectrophotometer
Click on the image to view the original image
Product: views:22BK-S360 with PC Analysis Software Scanning UV/VIS Spectrophotometer 
Branch: BIOBASE
Unit Price: Negotiated
Min.Order:
Supply:
Delivery: Shipment within days since the date of payment
Valid until: Long Term
Updated on: 2019-12-03 18:43
  Negotiated
Product Details
Overview
Quick Details
Place of Origin:
Shandong, China
Brand Name:
BIOBASE
Model Number:
BK-UV100
Size:
560*430*320
Weight:
12 /11.5/ 12/ 11.5
Focal Length:
Spectrophotometer
Wavelength Range:
0.5-5nm
Measurement Range:
190-1100nm
Item Name:
UV/VIS SPECTROPHOTOMETER
Model:
BK-S360/380/390
Optical System:
Single Beam, Grating1200 lines/mm
Spectral Bandwidth:
4nm
Wavelength Repeatability:
≤0.5nm
Photometric Accuracy:
± 0.002A (0-0.5Abs), ± 0.004A (0.5-1.0Abs), ± 0.5% T (0-100% T)
Photometric Repeatability:
0.001Abs (0-0.5Abs), 0.002Abs (0.5-1.0Abs),≤0.2% T (0-100% T)
Stability:
± 0.001A / h @ 500nm
Noise:
± 0.001A
Photometric Mode:
T, A, C, E
Supply Ability
Supply Ability:
1000 Set/Sets per Month
Packaging & Delivery
Packaging Details
Wooden case or carton package.
Port
Qingdao

 Scanning UV/VIS Spectrophotometer BK-S360 with PC analysis software

Product Description

 

 Application:

Spectrophotometers are widely used for Organic chemistry,Inorganic chemistry,Life sciences,foods,Medicine and health,Agriculture,Geology,Metallurgy and Environment etc.fields.

Features of UV/VIS Spectrophotometers :

Large LCD screen (128*64 Dots)

Imported & Environmental Deuterium lamp, preventing from Ozone inhalation

 High-class grating , wholly hermetic light path design, ensures the super low stray light

Real-time monitoring the lifetime of Deuterium lamp and Tungsten lamp with advanced system

Pre-aligned design ensures the user can change lamps conveniently

Wavelength calibration, wavelength setting, change lamp source and dark current calibration automatically

With Si02 coating optical mirror, reducing the pollution from outside fully

Optional PC Software to expand the applications to Quantitative, Multi-Wavelength and Kinetics

Widely used for Organic chemistry, Inorganic chemistry, Life sciences, food, Medicine and health, Agriculture, Geology, Metallurgy and Environment etc. fields

Basic Fuctions:

1. Photometry

Test Abs., Transmittance by fixed wavelength

2. Quantitative

a. C Mode: EstablishC=K*A curve, test sample concentration

b. F Mode: Establish A=K1*C+K0, test sample concentration

c. Display and save curve, test data (V-1200,UV-1200).

 
 
Technical Parameters of UV/VIS Spectrophotometers:

Model

BK-S360

BK-S380

BK-S390

Optical System

Single Beam, Grating1200 lines/mm

Wavelength Range

190-1100nm

Spectral Bandwidth

1.8nm

1nm

0.5,1,2,4,5nm

Wavelength Accuracy

± 0.3nm

Wavelength Repeatability

≤0.2nm

Photometric Accuracy

± 0.002A (0-0.5Abs), ± 0.004A (0.5-1.0Abs), ± 0.3% T (0-100% T) 

Photometric Repeatability

0.001Abs (0-0.5Abs), 0.002Abs (0.5-1.0Abs),≤0.1% T (0-100% T)

Stray Light

≤0.04% T @ 360nm; 220nm

Stability

± 0.001A / h @ 500nm 

Baseline Flatness

± 0.0015A

Noise

± 0.0004Abs

Display

65 thousand true color 7 inch TFT LCD(480 *800)

Photometric Mode

T, A, C, E

Photometric Range

0-200% T,-0.301~3.0A

Detector

Silicon Photodiode

Light Source

Deuterium Lamp, Tungsten Lamp

Input

Membrane Keypad

Output

USB Print and data output,Connect PC

Standard Accesseries

10mm glass cuvette *4 units  10mm quartz cuvette *2 units

Power Supply

110V/220±10% ,60/50Hz

Packing Size(mm)

740*570*440

Gross Weight(kg)

25

 
 
Accessories

 

 

 

 

Company information

BIOBASE group, founded in 1999 and been through high and stable development for 17 years.

The products we manufacture extends to most of the laboratory items and scientific analytical equipments.

BIOBASE group invests in science and technology research, aim to keep impoving products performance and quality as well as develop new products to meet customers wide requirement.

 

 

 

 

 

 

Our service:                                                                           
We satisfy our customers by offering comprehensive support, purchase convenience and we are ready to serves more and more BIOBASE users.
BIOBASE group, serving global distributors and its loyal end users, is becoming one of the most important scientific services supplier.

 

Our mission is to enable our customers to make the world healthier, cleaner and safer.

 

 

 

 

Main Products:                                                                     

Biological Safety Cabinet, Fume Hood, Laminar Flow Clean Bench, Refrigerator, Incubator, Cool House, Lab Waster Disposing System etc.
NSF model Biological Safety Cabinet, New Model Biological Safety Cabinet, Biochemistry Analyzer, ELISA; Work Station; Water Purifying System, Drying oven, Incubator, Refrigerator and freezer, Autoclave, Clean booth, Dispensing booth, Pathological sampling bench, filters etc.

 

 

 

 

 

BIOBASE Certificates

 

 

  

BIOBASE exhibitions

 

 

BIOBASE Exhibition:                                                           

 

 

Every year,BIOBASE attend many exhibitions all over the world.Global customers come to our booth to perfer our products.

 

Production line

 

 

BIOBASE Production Line:                                              

 

 

 

 

 

 

 

 

 

 

 

 

Package and Delivery

Packaging details: 

Mainly packaged by wooden case or carton.

 

Delivey details: 

7~15 days after payment confirmed.

 

 

 

  

Contact

Thanks for your Visiting, welcome to inquiry for special offer!

 

Wendy Shang

Sales Manager of Biobase China

Website: www.meihuatrad.com  www.biobase.cn
Tel:+86-531-55697931  Cell: +86-15275312292
Email: sales112@ biobase.com
Skype/Whatsup/Viber: +86-15275312292
Wechat: MEIHUA-38

 

询价单
total0items  Comments