IP66 Zhaga Controller Socket Base & Cover
Professional Photocell Manufacturer here now.
OEM and ODM One-stop service Customized, happy send sample to you confirm quality.
Modle | JL-711A1 | JL-711A2 |
Power supply |
Rated Voltage:12~24VDC,Drive Current:10mA
|
|
Average Power Consumption |
12V/5mA;24V/6mA
|
|
Sensor Type |
Photoresistor
|
|
Spectrum Collection Range |
350~1100nm, peak wavelength 550nm
|
|
Dimming Interface |
Mode: 0~10V; Accuracy: ±2%; Drive Capacity: 20mA (typical)
|
|
Default Lighting Threshold |
50Lux(±10)
|
|
Real-time turn-off illuminance threshold |
The ambient illuminance after turning on the light to 100% brightness each time +40Lux (±10) Lower limit: 50+40Lux (±10) Upper limit: 6000 Lux (±100)
|
|
Reflected Light Compensation upper limit |
6000Lux(±100)
|
|
Initial action |
After power on, the light is turned on by default at 100% brightness and maintained for 5 seconds, then the light is automatically turned off and enters the self-sensing operation mode *1
|
|
Light on delay |
5s (continuous 5S to meet the lighting illuminance to act)
|
|
Turn off delay |
20s (continuous 20s to meet the light-off illumination)
|
|
Dimming gradient duration 0~100% or 100~0% |
8s
|
|
Midnight |
No |
Light-down trigger point: the center point of the average night length in the first 10 days (the default call night length base on the first day is 10 hours) Brightness reduction ratio: 50% Light-down duration: 40% of total night length Less than 10 days are calculated based on actual days |
Mechanical Vibration |
IEC61000-3-3 |
|
Flammability Rating |
UL94-V0 |
|
Working temperature |
-40℃~70℃ |
|
Storage temperature |
-40℃~85℃ |
|
Working environment humidity |
5%RH~99%RH |
|
Shell protection |
IP66 |
Instructions for use
1. If the negative pole of the auxiliary power supply of the driver and the negative pole of the dimming interface are separated, they need to be short-circuited and connected to the light controller #2.
2. If the light controller is installed very close to the light source surface of the luminaire, and the power of the luminaire is relatively large, it may exceed the reflected light compensation limit, and the Own phenomenon.
3. Since the ZHAGA light controller does not have the ability to cut off the AC power supply of the driver, the customer needs to select the output current to be close to 0mA when using the ZHAGA light controller The driver, otherwise it may not be able to completely turn off the lamp phenomenon. As can be seen from the output current curve in the drive specification, the minimum output current is Close to 0mA.
4. The light controller only outputs the dimming signal to the driver, regardless of the power load of the driver and the light source.
5. Do not use your fingers to cover the photosensitive window during the test, because the gap between the fingers may pass light and cause the light to fail.