MUST low Frequency Online 1kva UPS Inverter EP2000 PRO without Battery
Product Parameter |
Model | EP20-0312 Pro | EP20-0612 Pro | EP20-0812 Pro | EP20-1012 Pro | EP20-0324 Pro | EP20-0624 Pro | EP20-0824 Pro | EP20-1024 Pro |
---|---|---|---|---|---|---|---|---|
Default Battery System Voltage | 12VDC | 24VDC | ||||||
INVERTER OUTPUT | ||||||||
Rated Power | 300W | 600W | 800W | 1000W | 300W | 600W | 800W | 1000W |
Surge Rating(20ms) | 900W | 1800W | 2400W | 3000W | 900W | 1800W | 2400W | 3000W |
Waveform | Pure Sine Wave | |||||||
Rated Output Voltage | Inverter:230VAC(+/-2% RMS), AVR:195VAC-245VAC | |||||||
Output Frequency | 50Hz/60Hz +/-0.2Hz | |||||||
Inverter Efficiency(Peak) | >75% | >81% | ||||||
Bypass Efficiency | >95% | |||||||
Output Transfer Time | Typical:6ms 10ms(max) | |||||||
AC INPUT | ||||||||
Voltage | 220/230/240VAC | |||||||
Selectable Voltage Range | 140~280VAC+/-2% | |||||||
Low Battery Alarm | 140VAC+/-2% | |||||||
Low Voltage Recover | 150VAC+/-2% | |||||||
High Battery Alarm | 280VAC+/-2% | |||||||
High Voltage Recover | 270VAC+/-2% | |||||||
Low Frequency Alarm | 45+/-0.2Hz | |||||||
Low Frequency Recover | 46+/-0.2Hz | |||||||
High Frequency Alarm | 65+/-0.2Hz | |||||||
High Frequency Recover | 64+/-0.2Hz | |||||||
Norminal Input Range | 50Hz/60Hz +/-0.2Hz | |||||||
AC Auto Restart | YES | |||||||
BATTERY | ||||||||
Minimum Start Voltage | Low Battery Voltage Cutoff+0.5V | Low Battery Voltage Cutoff+0.5V | ||||||
Low Battery Alarm | Low Battery Voltage Cutoff+0.5V | Low Battery Voltage Cutoff+1.0V | ||||||
Low Battery Cutoff | 10-12.0VDC | 20.0-24.0VDC | ||||||
High Battery Cutoff | Nominal Voltage+0.5V | Nominal Voltage+1.0V | ||||||
AC CHARGE | ||||||||
Floating Voltage | 13.5 /13.6/ 13.7VDC | 27.0/ 27.2 /27.4VDC | ||||||
Nominal Voltage | 13.8~14.5V | 27.6~29V | ||||||
Maximum Charge Current | 300W | 600W | 800W | 1000W | 300W | 600W | 800W | 1000W |
10A | 20A | 25A | 30A | 5A | 10A | 15A | 15A | |
BYPASS & PROTECTION | ||||||||
Input Waveform | Pure Sine Wave | |||||||
Input Frequency | 50Hz or 60Hz | |||||||
Low Frequency Trip | 45+/-0.2Hz | |||||||
Low Frequency Trip | 65+/-0.2Hz | |||||||
Overload Protection | 110%~125%R Load fault after 30S; 125% ~150%R Load fault after 3s ;>150%R Load fault after 500ms | |||||||
Over Temperature Protection | >90℃ | |||||||
Bypass Output Protection | 10A 250VAC | |||||||
Output Circuit protection | YES | |||||||
Battery Reverse Protection | Optional | |||||||
Battery Low Voltage Protection | YES | |||||||
Battery High Voltage Protection | YES | |||||||
Bypass Breaker Rating | 10A | |||||||
Maximum Bypass Current | 10 |
Product Packing:
MUST Factory Production Lines:
MUST Certifications:
National High-tech Enterprise Shenzhen National High-tech Enterprise
Frequency Asked Questions:
Q1: How to choose a right inverter?
A1:Tell us your demand, then our sales will recommend a suitable inverter to you.
Q2: What's the different between inverter and solar inverter?
A2: Inverter is only accept AC input, but solar inverter not only accept AC input but also can connect with solar panel to accept PV input, it more save power.
Q3: How about the delivery time?
A3: 7 days for sample; 25 days for bulk order.
Q4: What is the warranty of inverter?
A4: One year warranty on Must-Solar product.
Q5: How to solve the technical problem?
A5: 24 hours after-service consultancy just for you and to make your problem to solve easily.