Product Description
LED EMERGENCY DRIVER
UFO-LEDEM Series LED Emergency Battery Pack
Optimized for internal UFO fixture
Constant power output on emergency mode.
One Piece Design with Metal Housing,IP65 degree
2 -in- 1 ,walterproof LED test switch and indiciator light included,2.4G mode as option.
Emergency output to LED driver AC input ,simple wiring .
Evaluated to UL 924 requirements
Ordering Information:
Model | Voltage input | Output power | Output voltage | Emergency time |
EMUFO-25170-TT | 100-347V | 25W | 170vdc | 90 mins |
Installation:
The UFO-LEDEM does not affect normal fxture operation and may be
used with a switched or unswitched fixture. If a switched fixture is used
an unswitched AC power supply must also be connected to the UFO
LEDEM, and must be fed from the same branch circuit as the fxture’s AC
ballast.
Illumination:
UFO-LEDEM provides 25W/40W lumen output during emergency illumination for
a minimum of 90 minutes.
Safety Regulation:
Certificate |
Approval Marks
|
Standard | Valid | Remarks |
UL | UL924 | YES | North America | |
cUL | CAN/CSA-C22.2 NO. 141 | YES | Canada | |
BC | CEC Title 20 | YES | California | |
FCC | FCC | YES | North America |
UL 924 Damp Location Listed
NFPA 101 (Life Safety Code)
NFPA 70 (National Electrical Code)
Warranty:
5 Years Full Warranty
SPECIFICATION:
Input Voltage------(Universal)120-277Vac 10
Input Power(120V/277V)----810Watts(MaOutput Current-----0.1A(@170Vdc)
Power Factor---->0.5
Power Voltage--------175Vdc
EMI(Radiated and Conducted)-----FCC C(charge anSurge protection----Meets ANSI/IEEE C6
Emergency Operation---90 minutes
Operating Temp-----5° to 50°C
Battery------Lithium battery or Ni-MH
ACCESSORIES (ORDER SEPARATELY):
SPRTS Remote Test Switch/Charge Remote Test Switch/Charge
Indicator Module
SPECIFICATIONS:
Operation
AC operation, when AC power supplies to the AC driver and , the AC driver will operate the
LED load as designed. Then the will be kept as charging status and the indicator light will
keep lighting. When press the test button, it will change into emergency status at a reduced
lumen output for 30 seconds, during this time, the indicator will flash slowly then 30 seconds
later, it will recover into AC operation Emergency operation, When AC power fails, automatically
switches toemergency mode, keeping the LED load illuminated at a reduced lumen output for
a minimum of 90minutes, during this time, the indicator will flash slowly ( light on for 2 seconds,
off for 2 seconds ),when AC power is restored, it will return to charging mode, and the indicator
light will keep lighting
Self-Diagnostic:
The contain a control/monitor circuit which will perform a 30-second discharge test once a
month and a full 90-minute discharge test once a year. At this time, the unit simulate an AC
power failure and automatically switch to emergency mode.During routine testing, the unit
will monitor the operation of the LED load, battery voltage, and emergency duration, if the
unit detect any problems, the indicator will flash quickly
DIMENSIONS:
Wiring Diagram:
above 25W / 40W fixture wiring diagram
LED EMERGENCY DRIVER
UFO-LEDEM Series LED Emergency Battery Pack
Caution:
During AC operation, remember no touch or remove any wires in case of electric shock.
During emergency operation, before touching and disconnecting the wires, remember to press
the test button again to make the led lamp and indicator light off to avoid electric shock .
The voltage input to the dimmable wires(DIM+,DIM-) of emergency LED driver must less than 20Vdc.
For of EMUFO-25170-TT better work with LED lamp not emergency LED driver
more than 150W, for EMUFO-40170-TT must work with LED lamp not more than 300W.
This emergency LED driver only work with LED lamp with dimmable function.
Accessory
Packaging & Shipping
Our Services
1.we provide our professsional engineer serivice for our clients.
2. we can do the sample test and dialux ect
3.label color OEM design
Company Information