Technical Data:
OPCT10AL (1000/1) |
OPCT10AL (2000/1) |
OPCT10AL (3000/1) |
Unit |
|
Rated input |
5 |
5 |
80 |
A(AC) |
Rated output |
5 |
2.5 |
26.66 |
mA(AC) |
Rated sampling load |
50 |
200 |
100 |
Ω |
Rated sampling voltage |
0.25 |
0.5 |
2.666 |
V(AC) |
Turns ratio |
1000/1 |
2000/1 |
3000/1 |
—— |
Phase shift |
100 (5A,0Ω) |
100 (5A,0Ω) |
60 (80A,0Ω) |
' |
Accracy error |
0.5 |
0.5 |
0.5 |
% |
Linearity |
0.3 |
0.3 |
0.3 |
% |
Measuring current |
0~60A (RL≤10Ω) |
0~60A (RL≤75)Ω |
0~80A (RL≤100Ω) |
A(AC) |
Maximum current |
—— |
0~80A (RL≤10Ω) |
0~100A (RL≤10Ω) |
A(AC) |
DCR |
50±5 |
220±20 |
420±30 |
Ω |
Weight |
54.2 |
58.5 |
50 |
g |
Output line length |
1500 |
2000 |
1000 |
mm |
Note : Current transformers are prohibited to be used in open circuit, also can’t be connected to fuse.
Please connect the output of the transformer first,and then clamp the transformer on the bus under test.
PACKAGE:
Standard export carton packing.
DELIVERY TIME:
3-20 days after confirming order,detail delivery date should be decided according to