Homepage|Business Center|Save the Page|Get the App
普通会员

Dolight Optoelectronics Technology Co.,Ltd.

Product Category
  • No Category Yet
Search
 
Link
  • No links
Home > Products > Pro Trunk Lens Version for New Installation DWT540
Pro Trunk Lens Version for New Installation DWT540
Click on the image to view the original image
Product: views:12Pro Trunk Lens Version for New Installation DWT540 
Unit Price: Negotiated
Min.Order:
Supply:
Delivery: Shipment within days since the date of payment
Valid until: Long Term
Updated on: 2019-09-03 08:45
  Negotiated
Product Details

Products Details


Thanks for choosing DW pro trunk for new installation version linear series. DW pro trunk for new installation linear ilight, which is easy and quick continous installation without any tools by the clips integrated inside. Different length of module anf rail is available. DW pro trunk lens version for new installation is a good choice for you.


◈  ADVANTAGE

bg


  • ①      TUV Listed CE, CB, and RoHS, SAA,ISO9001;

  • ②      Easy and quick continous installation without any tools by the clips integrated inside;

  •    140lm/W ; 160lm/W;free selection beam angle from Sharp 30°60°90° to flood 120°and from asymmetric 25°to double asymmetric 25°;

  •    1-10V dimming, Dali control optional;

  •    X,L,T shape Node connector available;

  •    White coated aluminum housing and silver color optional

  •    It could be used in shops, supermarket, office, ect.

  •   Different length of module and rail is available;

◈  TECHNICAL DATA  SHEET

bg


                                                                     Pro Trunk Lens Version for New Installation  

Material

Aluminum profile+PMMA

Colour scheme

 White coated aluminium housing/silver color

Installation type

Rotatory knob or holding clamp

Model

DWTP124/ DWTP124X

DWTP440/

DWTP440X

DWTP540/

DWTP540X

DWTP560/

DWTP560X

Dimensions( Length x Breadth x Height)

576 x65 x82mm

1148 x65 x82mm

1,434 x65 x82mm

1,434x65x82mm

Weight

Approx.1.5 kg

Approx.2.4kg

Approx.2.8 kg

Approx.2.8 kg

Protection type

IP40

Illuminant properties

Illuminant Type

LED-Moduls with Mid-Power-LEDs

Optical System

Wide,Narrow,wide,Flat and double Asymmetric light distribution

Luminous Flux

3120lm –3300lm

3120lm –3300lm

4,320lm –4,680lm

7,200lm -7,800lm

Luminous Output

140lm/w -160lm/w (Customized)

Colour Temperature

3,000K /4,000K / 5,000K /6,000K

Colour Rendering Index(Ra)

> 80

Dimming( Power control)

With / without DALI

Lifetime at (ta)30°

50,000 h

Electronic Properties

Power Rating

24W

40 W

48 W

60W

Protection class

SKI

Operating voltage

AC 180 - 240V      (AC100-277V)

Frequency

50 / 60 Hz

Installation Requirements

Application areas

Halls,warehouses,manufacturing facilities,sales premises

Specific Installation

Rail- Light System

Installation height

3 to 20m

Permissible ambient temperature (ta) 30°

-25℃to +35℃

Other properties

Certification

CE / TUV / SAA

Connection with circuit breaker (B16)

200 Pcs

120 Pcs

100 Pcs

80 Pcs

Special features

End cover

IP20


◈  PERFORMANCE

bg

Free Selection Beam Angle:


Sharp-30°

Narrow-60°

Wide-90°

Asymmetric

 (Left/ Right)Pending 25°

Double

 Asymmetric25°

图片.png

图片.png

图片.png

图片.png

图片.png


90°  60W  pro trunk linear



◈  SPECIFICATION

bg


               

Photometric Data

               

size



Efficiency

Model No.

Wattage

Luminous flux

CRI

LED

Dimension

140lm/W

DWT124

24W

3360lm

80Ra

SMD2835

570x65x82mm

DWT440

40W

5600lm

80Ra

SMD2835

1135x65x82mm

DWT540

40W

5600lm

80Ra

SMD2835

1415x65x82mm

DWT560

60W

8400lm

80Ra

SMD2835

1415x65x82mm

DWT124X

24W

3360lm

80Ra

SMD2835

570x65x82mm

DWT440X

40W

5600lm

80Ra

SMD2835

1135x65x82mm

DWT540X

40W

5600lm

80Ra

SMD2835

1415x65x82mm

DWT560X

60W

8400lm

80Ra

SMD2835

1415x65x82mm




◈  INSTALLATION INSTRUCTION

bg


• GENERAL SAFETY INSTRUCTIONS

 

• Installation and maintenance must be performed by authorised and trained staff.

• Before wiring, make sure that the cables are de-energised. During wiring work, make sure that the cables remain de-energised (e.g. prevent switching back on).

• Observe your national safety regulations for the installation and use of this lamp.

• The manufacturer accepts no liability for injuries or damage caused by unintended use or incorrect installation.

• If the lamp is retroactively modified, the person who made the modifications then becomes the manufacturer.

• To avoid risks, the lamp must only be operated if there are no visible signs of damage to components, in particular to the connecting cable.

• Only the manufacturer is authorized to replace defective components.

• The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similarly qualified person.

• All dimensions stated in mm.

• The drawings are not to scale.

• Technical changes are reserved


◈ ACCESSORY

bg

5 Wires, 7 Wires versions can be built into 2-3 loops node connector. All system components can be combined without tools. X, L and T connectors expand the syatems's application range. Each node connector has diversie of electrical feed-in and feed-out. 5 Wires, 7 Wires versions can be built into 2-3 loops node connector. All system components can be combined without tools. X, L and T connectors expand the syatems's application range. Each node connector has diversie of electrical feed-in and feed-out.



◈  APPLICATION

bg


♦ Commercial

♦ Boardrooms, offices, corridors

♦ Warehouse

♦ Supermarket






询价单
total0items  Comments