Homepage|Business Center|Save the Page|Get the App
普通会员

Sanforce Technology (Shenzhen) Co., Ltd.

Product Category
  • No Category Yet
Search
 
Link
  • No links
Home > Products > Hot sale 36 LED rechargeable Emergency light batteries power pack led panel light
Hot sale 36 LED rechargeable Emergency light batteries power pack led panel light
Click on the image to view the original image
Product: views:6Hot sale 36 LED rechargeable Emergency light batteries power pack led panel light 
Branch: Sanforce
Unit Price: Negotiated
Min.Order:
Supply:
Delivery: Shipment within days since the date of payment
Valid until: Long Term
Updated on: 2019-10-16 23:39
  Negotiated
Product Details
Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
Sanforce
Bulb Type:
LED
Battery Type:
Ni-Cd
Material:
metal
Usage:
emergency lighting
Certification:
CE
Specifications:
LED LIGHTS
Product Name:
LED rechargeable Emergency light batteries power pack led panel light
Input Voltage:
110V-265V 50/60HZ
Charge time:
24hrs
Warranty:
3 Years
Emergency Time:
2Hrs
Emergency Power:
18W
Output Voltage:
30~48V
inverter Size:
155*40*30mm
Metal Case Size:
customized
Battery:
Ni-cd Battery
Supply Ability
Supply Ability:
20000 Set/Sets per Month
Packaging & Delivery
Packaging Details
Inner box size:280*110*57mm
Outer box size:350*295*248mm
Port
Shenzhen or Hongkong
Picture Example:
package-img
Lead Time:
Quantity(Sets)1 - 500501 - 10001001 - 2000 >2000
Est. Time(days)101520To be negotiated

 LED emergency power supply is designed specifically to suit Constant Current type LEDs and ciruits.Utilizing DC/DC switcher circuitry.Product is compatible with wide range of LED fixture ideal for LED panel light light,LED down light and many others with extermal LED driver and low voltage(6~90),emergency output power 5%~100%.

Model  No.LMO102C018P
Product Name LED rechargeable Emergency light batteries power pack led panel light
Battery Type NiMH, NiCd,
Lighting Power36W LED panel
Emergency Power18w
Input voltage     AC110~265V, 50/60Hz
Battery protection     Yes
Operation temperature-20--70℃  , 65+20% RH
Highest Surface Temperature50°C
Battery Capacity12V 800mAh  Rechargeable Nicd battery pack
Charging Time>24h without break
Output Voltage in emergencyDC30~48V,130mAh
Suitable light sourceLED PANEL, DOWN LIGHT, CEILING LIGHT
Emergency power level50%
Emergency duration120 minutes
Product Weight  2.3kgs
Inverter dimension155*40*30mm
NoteCustom-Made battery to be configured with different back-up period and different light output levels. 

 

Desription

The emergency module including emergency inverter and Nicd D4000 battery,  Inverter automatically enable battery backup system to light on the lighting in less than 0.1 second during power off.  Green led indicator indicates battery charging and healthy status. Push test switch to stimulator main power off.

 

The product range to cover a variety of LED fixture ideal for low voltage board(15-90V DC)LED panel, ceiling light,down light, flood light..etc with external LED driver, integrated with LED panel 600*600 or 800*800 perfectly to provide emergency illuination in case of mains failure.

 

Advantage

1)Customized solution for inverter and battery, more economical

2)Life cycle for emergency inverter can reach 50,000 hour

3)Battery life can reach 500-800 cycles

4)Charging indicator equipped

5)Test switch to inspect the emergency line at any time.

6)3 years warranty

7)Excellent high temperature endurance 

8) CE, Rohs, AS2293 approved.

 

 

 

Our Services

 

Company Information

 

Sanforce is a manufacturer specializing in emergency conversion kits for LED and fluorescent lighting since 2008.
We cooperate with valuable supply chain, inspect all the incoming materials and set up strict product assurance system, such as SMT, Auto Aging test, Simulation test during our production process. We have very skillful and responsible workers, most of them have been working here over 6 years.
With strong technical support and customer- oriented service, you can be sure that Sanforce is ready to support you, whatever your needs.

 

Why choose us

 

1.What is your main product line is made?

We are dedicating to LED emergency power pack for commercial lighting, research,
manufacturing and sales, aiming to be a leading emergency lighting backup power producer.
Our main products include:1). Constant current output of Led conversion kit for LED panel
light, LED down lights and other LED light applications with external driver. Emergency
output power differed from 5-90% according to customer’s requirement.
2). 100% emergency output power of emergency kits for LED tube with AC220V or DC110-150V
output.
3). Emergency lighting battery packs for Fluorescent tube 14-98W.
4). High Temperature rechargeable NiCD and NiMH battery pack for emergency control gear
5). Emergency LED T8 tube and min LED T5 3W-4W
6) Constant power emergency kits.

 

 

2.Can inverter be commonly used for any type of light applications?

 

No. It must be confirmed with us case by case

 

3.Can fluorescent emergency kit be used for LED light?

NO
The emergency output is high voltage and high frequency (1000v 230KZ))for fluorescent, That
is not applicable for LED system.

 

4.What is the difference between high temperature battery and normal temperature battery?

The main difference is that high temperature battery can be trickle charged well even
though the emergency power kit stay at high temperature due to insufficient radiating
caused by the lights working for long time, while normal temperature battery may stop
charging in such conditions that result in emergency light failed to work. We would highly
recommend to use high temperature battery for emergency lighting kit.

 

5.Does battery have an end-of-charge detection/over voltage protection?

No, The battery is being charged all the time, The charging current will be decreased based
on the capacity status during the charging process. For NiCD and NiMH battery, it is
applicable for constantly charging without any risk even though no over voltage
protection. But under voltage protection is set up for discharging.

 

6.How long (months/years) before the battery discharge time goes below 2 hours?

Normally 2 years later.For Nicd battery, the capacity will be reduced by 10% at first of
year and 20%of the second year, it will remain 70%-80% after total 3 years.


7.If the battery reaches full charge, (NiCd in our case), and the fitting is supplied with
220VAC all the time, can you explain how does it not damage the battery when it keeps
charging all the time?

For Nicd battery we offered you, we set up the charging current at 0.05C(1/20 battery
capacity) that is suitable for long time constant charging, no any damage for battery. It’
s characteristics of NiCD itself.

 

8.What are your market reach throughout the region?

Our markets mainly spread over Europe, South of America, Africa and Asian Pacific region as
well as domestic marketing, we have 8 years of experience in foreign trade, we have worked
with buyers of lighting importers and distributors etc.

 

 

9.Can the light work as emergency function immediately once we installed the emergency conversion kit into standard lighting applications?

 

NO
The emergency output is high voltage and high frequency (1000v 230KZ))for fluorescent, That
is not applicable for LED system.


10.Your factory or trading company?

We are a factory, we provide OEM services and accept small order. We only focus on the
manufacturing of products-Emergency Conversion Kits.

 


11.You have the ability to do independent research and development?

Our engineering department has 3-5 people, we have the research and development
capabilities. We also collect each customer’s feedback regularly, We have the ability on
product improvement and new product development.

 


12.Why is the fluorescent tube blackened once activate with emergency kit?

The reason is that our emergency output is one way of high frequency pulse,the output of
pulse waveform is not completed but only half of that .But itwill not affect the
functionality of fluorescent tube because of the emergencyrunning is not frequent. Unless
emergency back up functionality is neededall the time that will impact the life of tube
slightly.

 