- Place of Origin:
- Guangdong, China
- Brand Name:
- SUMRING
- Model Number:
- SR-P01A
- color:
- red
- type:
- conventional
- fire alarm control panel:
- 4 zone
- Function:
- Fire detection
- AC POWER:
- 220VAC, 50 Hz.
- battery:
- Sealed lead-acid batteries only
- Maximum charging circuit:
- 27.6VDC @ 0.8 amp for normal flat charge
Packaging & Delivery
- Selling Units:
- Single item
- Single package size:
- 48X42X18.5 cm
- Single gross weight:
- 10.0 kg
- Package Type:
- paper carton
- Picture Example:
- Lead Time:
Quantity(Piece) 1 - 100 >100 Est. Time(days) 5 To be negotiated
Manufacturer price 4 zones fire alarm system control panel
Features:
This is Four Zone Style B (Class B) Initiating Device Circuits (IDCs), the zone accept
two-wire smoke detectors and any normally-open contact devices.
Two Supervisory Input with DC12V output, ideal to connect security alarm devices.
Three General Alarm, Trouble and Supervisory, Form A Relay Output.
One, Two, Four Built-in Sound Output, Style Y (Class B) Notification Appliance (Signal) Circuits
(NACs), NACs may be programmed: Silenceable or Non-Silenceable.
3.0 amps of total system power. Resettable DC24V & Non-resettable DC24V Output.
Zone Input Short Circuit can be set to “Alarm” or “ Fault” mode.
RS485 Communication Port (optional).
Automatic/Manual mode can be programmed.
Disable/Enable control per Zone (IDC) can be programmed.
Disable/Enable Sound Output(NACs) can be programmed.
Specification:
AC POWER: 220VAC, 50 Hz.
BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for
normal flat charge. Maximum battery charger capacity: 18AH battery.
NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate
battery box.
Total DC24V system power: 3.0 amps.
Maximum current per NAC: 1.25 amps.
Maximum battery charging capability: 18 AH.
Resettable four-wire smoke detector power output.
Non-resettable power output.
Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC
(resistive), 2.0 amps @ 30 VAC (resistive).
Product show:
This fire alarm control panel can Match any 2/4-wire smoke heat detector,strobe siren,fire bell,manual call point ect
smoke detector | 2 wire, 4 wire optiona, photoeletrci type |
heat detector | 2 wire, 4 wire optional, rate of rise or fixed temeparture |
strobe siren | wired type, with or without strobe |
fire bell | wired type, indoor or outdoor type |
manual call point | resettable type or breaking glass type optional |
Not only the alarm control panel we have, but also we offer all kinds of detectors if you want, we are looking forward to your inquiry, thank you
Payment terms:L/C,D/A,D/P,T/T, Western Union,Paypal ect
Delivery time :Normal order within 7 days,bulk order 10-15 days
Packing:paper carton
Tel: 86- 755-89571625
skype :cnsumring03
TradeManager:sumring