24VDC 60W 50W Triac Constant Voltage Dimmable Junction Box Led Driver Transformer for led strip light and led Module
Phase-cut / Triac dimmable LED Driver
Specification:
Model | ZH-DV60U24-KT | |
Certificates | CLASS 2 UL CUL 8750 | |
Output | DC Voltage | 24V |
Rated Current | 2.5A | |
Rated Power | 60W | |
Voltatge Tolerance | ±0.5V | |
Voltage Regulation | ±0.5% | |
Load Regulation | ±1% | |
Input | Voltage Range | 110-277VAC |
Frequency Range | 47-63Hz | |
Power Factor (Typ.) @ full load | 0.98@120VAC 0.97@277VAC | |
THD (Typ.) @ full load | <20% | |
Efficiency (Typ.) @ full load | >85% | |
AC Current (Max.) | 2.3A@110VAC | |
Inrush Current (Typ.) | 15A, 50%, 1.4ms | |
Leakage Current | <0.50mA | |
Protection | Short Circuit | shut down o/p voltage, re-power on to recover after fault condition is removed |
Over Loading | ≤120% constant current limiting, auto-recovery | |
Over Termperature | 100℃±10℃ shut down o/p voltage, automatically recover after cooling | |
Environment | Working TEMP. | -40~+60℃ |
Working Humidity | 20~90% RH, non-condensing | |
Storage TEMP. Humidity | -40~+80℃, 10~95% RH | |
TEMP. coefficient | ±0.03%/℃ (0~50℃) | |
Vibration | 10~500Hz, 5G 10min./1 cycle, period for 60min, each along X,Y,Z axes | |
Safety & EMC | Safety Standards | UL 8750 |
Withstand Voltage | I/P-O/P:1.88KVAC | |
Isolation Resistance |
I/P-O/P:100MΩ/500VDC/25℃/70%RH |
|
EMC Emission | FCC Part 15 B | |
Others | Net. Weight |
720g |
Size | 177*70*35mm (L*W*H) | |
Packing | 20PCS/CTN | |
Notes |
1. All parameters if NOT specially mentioned are measured at 120VAC input, rated load and 25℃ of ambient temperature. 2. To extend the driver's using life, please reduce the loading at lower input voltage. |
Product Picture:
Wiring Diagram:
12/24-Volt DC Installation Guide:
Highly efficient, stablized, constant voltage DC power for LED lighting
20W-96/100W 12V 24VDC Class 2 Voltage LED Driver (UL Listed)
General
•This driver is to be installed in accordance with Article 450 of the National Electric Code and installed by qualified and professional electrician.
•Please make sure the driver is installed with adequate ventilation around it to allow for hear dissipation.
Before Installing
•Power must be disconnected at all times during installation.
•Observe polarity of the 12/24 volt DC output. Failure to observe polarity could damage LED lighting.
•Total wattage of all LED fixtures used must not exceed the maximum watt rating of the power supply.
Input Connections / Grounding
•Use the clamp connectors to secure cords and wires.
•Route and secure wires so they will not be pinched or damaged.
•All wiring must be in accordance with national and local electrical codes, low voltage Class 2 circuit. For wire runs inside of walls, use properly certified CL2 or better cabling and appropriate mounting hardware. If you are unclear as to how to install and wire this product, contact a qualified electrician. Failure to install this device properly may result in electrical shock or fire.
•Do not install Class 2 low voltage wiring in the same runs as AC main power. If AC and low voltage wires across, keep them at 90-degree angles.
•The driver case MUST be grounded in accordance with the N.E.C. Connect the ground wire to the driver green wire.
Output Wire
•Bring the wires of the light fixture through the other clamp connector and connect them to the driver wires - positive to the red (+) wire and negative to the blue (-) wire.
Dimming
•Dimmable with any standard MLV/Incandescent TRIAC (Leading edge) dimmer switched.
•Dimmer switched is to be installed on the input (120VAC side) of the driver.