Home > Products > Digital Temperature Humidity Controller Regulator Thermostat Hygrostat Control with Humidity Sensors 220V
Digital Temperature Humidity Controller Regulator Thermostat Hygrostat Control with Humidity Sensors 220V
Click on the image to view the original image
Product: views:4Digital Temperature Humidity Controller Regulator Thermostat Hygrostat Control with Humidity Sensors 220V 
Branch: TAXNELE
Size: 10X10X10 cm
Unit Price: Negotiated
Min.Order:
Supply:
Delivery: Shipment within days since the date of payment
Valid until: Long Term
Updated on: 2019-11-19 19:17
  Negotiated
Product Details
Overview
Quick Details
Place of Origin:
Zhejiang, China
Brand Name:
TAXNELE
Model Number:
Temperature Humidity
Measurement Temperature range:
-20℃~80℃
Measurement Humidity range:
1%RH-99%RH

Packaging & Delivery

Selling Units:
Single item
Single package size: 
10X10X10 cm
Single gross weight:
0.15 kg
Package Type:
Standard Export Packing
Lead Time:
Quantity(Piece)1 - 1000>1000
Est. Time(days)7To be negotiated

  

Parameters

 

Product Description

Control range1%RH-99%RH
Load power10A/AC220V
Measurement range-20℃~80℃
Humidity range1%RH-99%RH
Measurement error±3%RH(environment temperature at 25℃)
Temperature precision1℃ Humidity precision:1%RH
Display accuracy1%RH
Power SupplyDC12V//220V(Choose)
Output type10A relay output probe type
TemperatureNTC precision ±1℃
HumidityResistance type sensor precision ±3℃
Dimension90*60*26.5mm(L*W*H)
Temperature control objectOne channel temperature(heating and refrigeration ventilator)


Or humidity(Dehumidify or humidify electrical appliance)

Probe line length:standard 1.5m

Permanent memory of parameter:set the all parameter with permanent memory

Power failure at the operation time:run after the power supply.

Working environment: temperature 0-55℃ humidity90%RH without condensation

 

Menu code description:

 

 

Dehumidification control: The way of mode control (code HC) it will be dehumidification control when setting as C.For example,set the humidity control value as 50% RH and humidity difference as 5%,relay start output,When environment humidity value ≤setting humidity value(50%RH),relay close output.

Damping control:The way of humidity control  (code HC) ,set H as damping mode,for example,set the humidity control value as 50%RH and humidity difference as 5%RH. When temperature humidity value ≤setting value(50%RH)-difference/(5%RH) ,relay start output.when temperature humidity ≥setting value(50%RH),relay stop output.

HC:mode selection,H means humidifying mode,C means dehumidificatio mode.

D:return difference, start the humidify when in the humidifying mode=displaying humidity-return difference.start the humidify when in dehumidification mode=displaying humidity + return difference.

PU:Delay to start.when relay stop output and start timing.the interval time of next boot must greater than delay start time to avoid start frequently.

HP:Humidity upper limit alarm:when humidity exceed upper limit alarm,digital tube displaying "-H-",humidity lower than alarm setting value it will return back from alarm automatically.

LS;Humidity lower limit alarm:When humidity exceed lower limit,digital tube display"-L-",humidity higher than alarm setting value it will return back from alarm automatically.

CA:Humidity correction:Humidity correction value plus displaying value.For example:humidity display 50% RH correction humidity increase 5% RH,then display humidity will be 55%RH.

Heating mode:Mode control way (code HC) set as H ,it is heating mode.For example,set control heating value as 35℃,temperature return difference is 2°.when environment humidity value ≥setting temperature value(35℃)-return difference(2 ℃),relay start output.when humidity value≤setting humidity value (35℃),relay close output.

Cooling control:The way of mode control ,set (HC code) as C ,it is cooling mode.For example,set cooling as 35 ℃ and temperature return difference as 2 ℃.When environment value ≥ setting temperature value (35℃)+return difference(2℃),relay start output:when environment humidity value≤setting humidity value(35 ℃),relay stop output.

HC:Mode selection,C means cooling mode,H means heating mode.

D:return difference,start temperature when in heating mode= displaying temperature"-return difference.Start temperature when in cooling mode=displaying temperature+return difference.

PU:Delay to start,When relay stop output and start timing,the interval of time must greater than delay start time to avoid start frequently.HP:temperature upper limit alarm:when temperature exceed upper limit alarm,digital tube display"HHH",temperature lower than alarm setting it will return back from alarm automatically.

LS:temperature lower limit alarm:when temperature exceed than lower limit alarm,digital tube display "LLL",temperature higher than alarm setting it will return back from alarm automatically.

CA temperature correction:Humidity correction value plus display humidity value,for example:humidity displaying 35℃ ,correction humidity increase 5℃,then temperature should be 35℃.

Reset:Press left up and down keyboard until screen displaying 888,then it will coma back to factory reset.     

 