Home > Products > 4 Pressure Sensor Bet Specific Surface Area Analyzer For Powder Material And Pore Size Analyzer
4 Pressure Sensor Bet Specific Surface Area Analyzer For Powder Material And Pore Size Analyzer
Click on the image to view the original image
Product: views:64 Pressure Sensor Bet Specific Surface Area Analyzer For Powder Material And Pore Size Analyzer 
Unit Price: Negotiated
Min.Order:
Supply:
Delivery: Shipment within days since the date of payment
Valid until: Long Term
Updated on: 2021-12-28 12:24
  Negotiated
Product Details
Product Description
4 Pressure Sensor Bet Specific Surface Area Analyzer For Powder Material And Pore Size Analyzer

 

 

Features

TMAX-1020 Surface Area And Porosimetry Analyzer accords with the international standards ISO9277, ISO 15901 and National standard Gb-119587. It tests desorption process in the principle of static capacity measurement tested through static gas balance and pressure tested. They are tested in the temperature of liquid nitrogen. The gas of known quantity is filled into the sample tube and the pressure is to fall, then  the Moore's quality of  adsorbed gas is calculated. With calculated balance adsorption quantity and theoretical model, the instrument evaluates the parameters such as  single-point, multipoint  BET specific surface area, Langmuir specific surface area of the samples; BJH mesoporous,     macroporous area,area distribution; t-plot microporous and surface areas, Dubinin Astakhov microporous distribution,  Hovath-Kawazoe microporous distribution; DFT and MC aperture distribution model.

 

Guarantee for Trustworthy Tested Data

Reasonable connection of pipes, capability of s vacuum pumping, precision and sensitivity of sensors, automation of the instrument and numbers of the digital models for the different samples.

 

Modular Gas pipes Design

TMAX-1020 Surface Area And Porosimetry Analyzer accords with the most developed design ideas, designed with special modular stainless steel vacuum pipes . It is leak proof and pollution-free. It is high vacuum and avoids leakage due to excessive pipe connections. It is specially-designed research instrument for the micropores study, with diffusion pump to keep the system high vacuum.

 

Constant temperature

 Dewar flasks is self-developed with special internal structure, store the liquid nitrogen for more than 10 days. The liquid nitrogen is almost free of losses during the test so that the temperature of the tested samples is constant and that the Dewar flasks are protected as they are fragile and unfavorable for movement.

 

High-precision sensors

Several high-precision sensors and 22-bit AD converters ensure the precision of the specific surface area and aperture.

 

Developed theoretical model

With DFT and MC aperture distribution models, it is developed in the world, and is the Number One of the specific surface area and Pore size distribution Analyzers in China

 

Automatic operation

Adsorption and desorption processes are automatically controlled by computers and free of manual operation.

 

Technical characteristics

  1.  Single-point, multipoint BET specific surface area

  2.  BJH specific surface area, area distribution, total area

  3. T-plot micropores volume and surface areas, Dubinin Astakhov micropores size distribution, Hovath-Kawazoe micropores size distribution

  4DFT and MC aperture distribution model

 

Test principle

low-temperature nitrogen physical adsorption (static capacity)

Specific surface area

0.01 m 2 without upper limit

Analysis of range for pore size

3.5-5000  angstrom

Adsorbed gas

nitrogen

P/PO test range

1 X 10 -6 – 0.998

Pressure and temperature measurement

4 imported absolute pressure sensors 0-133 Kpa( precision 0.12%)

1 temperature sensor PT-100( Precision 0.1)

Dewar flask

2.0L, duration of 80 hours

Vacuum pump

Mechanical pump

Ultimate vacuum

1.0 X 10 -4 Torr

Measurement software

Adsorption /desorption isotherm curve

Physical parameter

535 X 435 X 720 mm 40kg (exclusive of vacuum pump)

Others

2tested sample and 3 pretreated samples   in the meantime

 

 

Specifications

Model

TMAX-1010

TMAX-1020

TMAX-1030

TMAX-1001

Inlet pressure sensor

3

Accuracy 0.12%

4

Accuracy 0.12%

6

Accuracy 0.12%

4

Accuracy 0.1%

Analysis station

1

2

3

1

Pore Size

3.5-5000angstrom

Test Principle

Low temperature nitrogen physical angstrom

(Static Volumetric Method)

Absorbed Gas

Nitrogen

Specific surface area

0.01m^2/g

without upper limit

0.0005m^2/g

without upper limit

P/PO Test range

 

1×10^-6--0.998

1×10^-8--0.998

Vacuum Pump

Mechanical pumps

Mechanical pumps+diffusion Pump

Ultimate

1.0x10-4 Torr

1.0x10-6 Torr

Degassing station

3

Output Report

Directly printed and Excel output the parameters such as adsorption /desorption isotherm, BET specific surface area, Langmuir specific surface area , t-plot micropores areas, BJH specific surface area ,Dubinin Astakhov micropores distribution,  Hovath-Kawazoe micropores distribution.

 

Applied range

It is applied in study and test of all kinds of materials such as zeolite, carbon material, molecular sieve, silicic acid anhydride, aluminum oxide,soil, clay, catalytic agent, organic metal  compound cageconstruction.

 

 

Product Images

 

 

 

 

Our Company & Team

 

Certifications
 
Cooperative Partner

 

Packaging & Shipping

PACKAGE:

     1 Standard exported package: Internal anticollision protection, external export wooden box packaging.

     2 Shipping by express, by air, by sea according to customers' requirements to find the most suitable way.

     3 Responsible for the damage during the shipping process, will change the damage part for you for free.

 

DELIVERY TIME:15-20 days after confirming order,detail delivery date should be decided according to production season and order quantity.

 