12v l1028 remote control battery a23
1.Electrical Characteristics
(Conditions : 1000Ω±0.5% load resistance, measuring time 0.3seconds, 20±2°C, tested within 30 days after delivery) l1028 battery a23
| Off-load voltage (V) | On-load voltage (V) | Acceptance Standard |
New battery | 12.3 | 11.5 | MIL-STD105E, AQL=0.4 |
After 12 mon. room temp. | 12.1 | 11.0 |
MIL-STD105E, AQL=0.4
|
2. Shelf Life
(One years after delivery under proper storage conditions.) l1028 battery a23
3.Service Output
(Conditions : Test temp. 20±2°C, tested within 30 days after delivery.) l1028 battery a23
| Discharge Condition | Average Minimum Discharge Time | |||
Discharge Load | Daily Discharge time | End Point Voltage(V) | New battery | After 12mth.at room temp. | |
Standard | 20KΩ | 24h | 6.0 | 110h | 104h |
Reference | 1KΩ | 24h | 6.0 | 3.5h | 2.8h |
Acceptance Standard:
(1) 9 pieces of battery will be tested for each discharging standard .
(2) The result of the average discharging time from each discharging standard shall be equal to or more than the average minimum time requirement. l1028 battery a23
4.Image