Overview
Quick Details
- Place of Origin:
- Zhejiang, China
- Brand Name:
- WINSTON
- Model Number:
- SP-75
- Output Power:
- 51 - 100W
- Output Type:
- Single
- Input Voltage:
- 85~264VAC/120~370VDC
- Output Voltage:
- 5VDC 12VDC 15VDC 24VDC 48VDC
- Output Frequency:
- 50/60Hz
- Output Current:
- 1.6A~15A
- Application:
- Led
- Certification:
- CE
- Warranty:
- 2 years
- Product Name:
- Power Supply Unit
- Type:
- Electric
- Protections:
- Short Circuit Overload Overvolt
- Efficiency:
- 80%
- Protection:
- Over-voltage
- Size:
- 179*99*33mm
- Name:
- 75w power supply
Supply Ability
- Supply Ability:
- 5000 Piece/Pieces per Week
Packaging & Delivery
- Packaging Details
- Single package size: 18X11X4 cm
Single gross weight:0.66 KG
- Port
- ningbo
WINSTON SP-75 CCTV With PFC 75W 5V 12V 24V 48V Power Supply Unit
Application
Technical data
Model | Ouput | Error | Range | Efficiency |
SP-75-5 | 5V,15A | ±2% | 50mVP-P | 72% |
S-75-12 | 12V,6.3A | ±1% | 50mVP-P | 77% |
S-75-24 | 24V,3.2A | ±1% | 75mVP-P | 80% |
S-75-48 | 48V,1.6A | ±1% | 75mVP-P | 80% |
3.Input:
Voltage range | 88-264VAC/170-370VDC |
Frequency range | 47-63HZ |
AC current | |
Inrush Current(max.) | 15A/115V 30A/230V |
Leakage current | <2mA/240VAC |
4.Output:
DC Adjustable rang | ±10% |
Over load protection | 105-150% hiccup mode,auto-recovery |
Over voltage | 115-150% hiccup mode,auto-recovery |
Setup,rise ,hold time | 200ms,100ms,30ms at full load |
5.Environment:
Working Temperature | -10°c-+50°c |
Working Humidity | 20-90%RH |
Storage Temperature,Humidity | -20-+85°c,10-90%RH |
Temperature coefficient | ±0.03%/°c(0-50°c |
Vibration | 10-500HZ,2G 10min./1cycle,60min.each along X,Y,Z axes |
6.Safety & EMC:
Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
Isolation ressistance | I/P-O/P,I/P-FG:100M ohms/500VDC |
7.Note:
1).The testing condition for the paramenter above is :230VAC input,rated load,2570% RH.Humidity.
2).Error.include the setting error,line stability and load stability.(Note:5).
3).Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.
4).Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.
5).Load stability test:the load is from 0% to 100%.
Product Description
Other products
S Series | |
DR Series | |
MDR Series 10W 40W 60W 100W | |
LPV Series 15W 20W 30W 50W 60W 100W 150W 200W 250W | |
NES Series 15W 25W 35W 50W 75W 100W 150W 200W 350W | |
LRS Series 35W 50W 75W 100W 150W 200W 350W | |
PFC Function Series SP-75W SP-100W SP-150W SP-200W SP-320W SP-500W | |
MS Series 15W 25W 35W 50W 60W 75W 100W 120W 150W | |
More |
Packaging & Shipping
FAQ
Why choose us
Company Information