Overview
Quick Details
- Place of Origin:
- Zhejiang, China
- Brand Name:
- WINSTON
- Model Number:
- MS-100
- Output Power:
- 51 - 100W
- Output Type:
- Single
- Input Voltage:
- 90-132VAC/180-264VAC by switch
- Output Voltage:
- 5V 12V 15V 24V
- Output Frequency:
- 50/60Hz
- Output Current:
- 0-20A
- Application:
- Led Strip
- Certification:
- CE
- Warranty:
- 2 years
- Product Name:
- CCTV Power Supply
- Type:
- Electric
- Protections:
- Short Circuit Overload Overvolt
- Efficiency:
- 86%
- Protection:
- Over-voltage
- Size:
- 159*98*38mm
- Name:
- PSU
Supply Ability
- Supply Ability:
- 5000 Piece/Pieces per Week
Packaging & Delivery
- Packaging Details
- 30PCS/CTN G.W.:16.5KG/CTN CTN Size:34*32*24cm
- Port
- ningbo
Factory MS-100 PSU 100W Single 5V 12V 15V CCTV Power Supply 24V
Application
Technical data
Model | MS-100-5 | MSF-100-12 | MS-100-15 | MS-100-24 |
Specification | ||||
DC output voltage | 5V | 12V | 15V | 24V |
DC output current | 0-20A | 0-8.5A | 0-7A | 0-4.5A |
Wave and noise | 100mVp-p | 120mVp-p | 120mVp-p | 150mVp-p |
Inlet stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stablity | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Efficiency | 80% | 83% | 84% | 86% |
Adjustable range for DC voltage | ±10% | ±10% | ±10% | ±10% |
AC input voltage range | 90-132VAC/180-264VAC by switch 254-370VDC 47~63Hz | |||
AC Impact current | Cold-start current 15A/115VAC 30A/230VAC | |||
Overload proctection | 105%-150% cut off the output, automatic recovery | |||
Over-voltage protection | 115%~135% shut down O/P voltage, re-power on to recover | |||
Setup rise hold up time | 200ms, 50ms, 20ms/230VAC at full load | |||
Withstand voltage | Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC | |||
Isolation resistance | Input and output internal:Input and enclosure,Output and enclosure:500VDC/100MΩ | |||
Working temperature and humidity | -10°C~+50°C(Refer to output derating curve),20%~90%RH | |||
Overall dimension | 159*98*38mm | |||
Weight | 0.55Kgs | |||
Note: | ||||
1.The testing condition for the paramenter above is :230VAC input,rated load,25°C70% RH.Humidity. | ||||
2.Error.include the setting error,line stability and load stability.(Note:5). | ||||
3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting. | ||||
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. | ||||
5.Load stability test:the load is from 0% to 100%. | ||||
6.C2,3,6must be knocked down. |
Product Description
Other products
S Series | |
DR Series | |
MDR Series 10W 40W 60W 100W | |
LPV Series 15W 20W 30W 50W 60W 100W 150W 200W 250W | |
NES Series 15W 25W 35W 50W 75W 100W 150W 200W 350W | |
LRS Series 35W 50W 75W 100W 150W 200W 350W | |
PFC Function Series SP-75W SP-100W SP-150W SP-200W SP-320W SP-500W | |
MS Series 15W 25W 35W 50W 60W 75W 100W 120W 150W | |
More |
Packaging & Shipping
FAQ
Why choose us
Company Information