Although the heat pump industry has developed to the present, people have enjoyed the Gospel of energy conservation, comfort and environmental protection brought by it, but it also has its own limitations.Due to technical limitations, some products cannot operate normally at low temperatures, which has become a key factor restricting the development of air energy.Just imagine, in the cold winter, the temperature in the north is very low, if encountered frost weather, if not timely protection, will seriously affect the normal operation of the heat pump.With the continuous maturity of the technology, the air source heat pump timely protection work, even if the winter frost is not afraid.
First, cleanliness is important
At ordinary times will pay attention to the cleaning of the machine, good maintenance.It is very important for the reliability and stability of the heat pump unit to check the important parts and the route of the unit carefully.Especially for the heat pump unit such fully automatic operation of the equipment, appropriate inspection is essential.
Second, strengthen the pipe insulation effect
Pipeline warmth is very important for engineering quality.If the outdoor temperature is too low, the temperature of the exposed pipe will also drop, and the direct result is that the water temperature in the pipe will also drop.It will affect the temperature of the room.Dealers should have the awareness of pipeline protection, do pipeline protection before cooling, and add "coat" to the pipeline in time.
At the same time, we can also build a sun shelter for the unit according to the needs, so as to prevent rain and snow.
Three, choose the appropriate water tank system
For example, the circulator will adopt the heating mode of large and small water tanks, adding a heating water tank to the original system. This mode is suitable for all types of engineering projects, but it is especially suitable for larger engineering projects.In cold regions, it is impossible for the air to run 24 hours a day. Especially in winter in some regions, the temperature is only -15℃ at night and hovering around zero during the day.Therefore, the operation time of the air energy unit is basically in the daytime, after passing through the heating tank, it enters the heat storage tank for storage.
Four, heat pump frost
In winter, the heat pump must be completely frost, if the frost is not completely finished to start the heat pump, will make the heat pump ice, and will be more and more, into a vicious cycle, leading to the heat pump can not work normally.