Before starting:
1. Check the adequacy of the water tank.
2. Check the oil when the "static full" position; it cannot be higher or lower than this position.
3. Check whether the battery polarity is correct; make sure to connect the positive and negative ground connections of the starter. Non-reverse.
4. Check whether the air supply pipes, gas pipes and pipe fittings are leaking, and the personnel on duty should closely monitor them to ensure that there is no leakage.
5. Keep the gas pressure between 80mm-200mm water column,
6. Cut off the valve handle in a comfortable reset state to ensure smooth air supply;
7. The idle switch is in the "idle" position.
8. The air switch is in the off position
9. The floating power switch is in the off position.