Product Details
- Place of Origin:
- China
- Brand Name:
- ASENWARE
- Model Number:
- AW-CFP2166-01
- Model:
- AW-CFP2166-01
- Main Supply Voltage:
- 110VAC or 240VAC
- Total output current limited:
- 500mA @ 240VAC
- Main supply monitor for fault:
- Yes
- Batteries:
- 12V2AH*2
- OEM/ODM:
- Available & Feasible
- Installation Way:
- Wall-mounted
- Dimensions(mm):
- 272*200*70mm
- Supply Ability:
- 500 Set/Sets per Month
- Port
- Shenzhen/Guagnzhou/HongKong
1 Zone Conventional Fire Alarm Control Panel , Fire Alarm Panel, Fire Alarm Systems For Building
Descriptions: fire alarm control panel / prices fire alarm systems/fire alarm system control panel/ gsm alarm system/fire alarm systems for building/8 zone conventional fire alarm control Panel
1. AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2. It has 2 level control mode by a lock
3. It has 24VDC and 5VDC power supply output.
4. Each zone has 1 circuit detectors input .
5. Each zone can be disable by a button.
6. It is modularized design, the panel can extend from 1 zone to 32 zones easily.
7. It has FIRE and FAULT signal output and 2 general sounders output.
8. It has RESET button to reset the panel and SILENCE button to stop BUZZER and SOUNDERS.
9. It has EVACUATE button to start a manual fire alarm immediately.
10. It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
11. It has an optional GSM module for fire alarm by SMS .
12. It is economic, user-friendly and easy maintenance.
Technical Parameters: fire alarm control panel / prices fire alarm systems/fire alarm system control panel/ gsm alarm system/fire alarm systems for building/8 zone conventional fire alarm control Panel
ITEM | 1Zone panel | 2Zone panel | 4-8 Zone panel | 12-32 Zone panel |
Model No. | AW-CFP2166-01 | AW-CFP2166-02 | AW-CFP2166-04-8 | AW-CFP2166-12-32 |
Power specification |
| |||
Mains supply voltage | 110VAC or 240VAC | |||
Internal power supply | 27.2VDC | |||
Total output current limited | 500mA @ 240VAC | 500mA @ 240VAC | 3A @ 240VAC | 3A @ 240VAC |
Main supply monitor for fault | Yes | |||
Battery protection for low voltage | Yes | |||
Batteries (default configuration) | 12V2AH*2 | |||
Detector circuit specification |
| |||
Number of circuit | 1 | 2 | 4-16 | 4-32 |
Line fault monitor for open circuit | Yes | |||
Line fault monitor for short circuit | Yes | |||
Line fault monitor for detector removal | Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor | |||
End of Line device | 6.8k Ω,5% tolerance, 0.25W (colour code-blue, grey, red, gold) | |||
Detector continuity diodes | Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault) | |||
Call point resistor value | 470 to 680 Ω, 0.225 or 0.5 watt | |||
Maximum number of smoke/heat detectors per zone | 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maximum voltage drop must not exceed 12 volts. | |||
Maximum number of manual call points per zone | No limit | |||
Sounder circuit specification |
| |||
Number of general circuits | 2 | |||
End of line resistor value | 6.8k Ω,5% tolerance, 0.25W (colour code-blue, grey, red, gold) | |||
Line fault monitor for open circuit | Yes | |||
Line fault monitor for short circuit | Yes | |||
Outputs fused AT | 400mA | |||
Maximum number of bells @ 20mA of each sounder output | 20 | |||
Fuses |
| |||
Battery fuse | 1.5A F 20mm | |||
Sounder outputs | 500mA F 20mm | |||
Fire and fault output |
| |||
Output type | NC and NO relay | |||
Maximum current | 100mA | |||
Connection block |
| |||
Largest acceptable conductor size | 2.5mm2 | |||
Smallest acceptable conductor size | 0.75mm2 | |||
Size and weight |
|
| ||
Dimensions(mm) | 272*200*70mm | 320*231*90mm | 395X502X124 | 362X565X124 |
Weight (without batteries) | 4kg | 5kg | 7kg | 8kg |
Weight (with batteries) | 5.8kg | 6.8kg | 9.6kg | 12.5kg |
fire alarm control panel / prices fire alarm systems/fire alarm system control panel/ gsm alarm system/fire alarm systems for building/8 zone conventional fire alarm control Panel
fire alarm control panel / prices fire alarm systems/fire alarm system control panel/ gsm alarm system/fire alarm systems for building/8 zone conventional fire alarm control Panel
Packaging Details: Plastic, Cartons, plywood case
Shipping:deliver by air mail or ship for your order( EMS, DHL,FedEx,UPS).
Delivery Time: 3-5 days
1. We offer OEM/ODM service.
2. Quality assuance and rliabilty
3. Professional and experienced R&D center can offer free technical support.
4. One year warranty and technical maintenance.
1. Certificate: CE, ISO9001
2. Payment terms: T/T,L/C,Western union,Money Gram.
3. Warranty: One year
Please contact me freely to get more information.
fire alarm control panel / prices fire alarm systems/fire alarm system control panel/ gsm alarm system/fire alarm systems for building/8 zone conventional fire alarm control Panel
Name: | Bella Yu |
Skype: | sales10_303 |
Tel: | 0086-755-27663815-804 |
ID: | cn1512961300 |
Email: | sales10 @asenware.com |
Asenware specialized in the Fire Alarm and BMS(Building Management System) over 10 years.
We develop and manufacture addressable fire alarm system, conventional fire alarm system and CCTV Security alarm system etc.
We can provide complete fire alarm solution.
fire alarm control panel / prices fire alarm systems/fire alarm system control panel/ gsm alarm system/fire alarm systems for building/8 zone conventional fire alarm control Panel
fire alarm control panel / prices fire alarm systems/fire alarm system control panel/ gsm alarm system/fire alarm systems for building/8 zone conventional fire alarm control Panel
Customer Reviews total 0 items