ITEM | 4 Zone panel | 8 Zone panel | 16 Zone panel |
Model No. | AW-CFP2166-04 | AW-CFP2166-08 | AW-CFP2166-16 |
Power specification | |||
Mains supply voltage | 100-240VAC | ||
Internal power supply | 27.2VDC | ||
Total output current limited | 1.6A @ 240VAC | 3A @ 240VAC | 5A @ 240VAC |
Main supply monitor for fault | Yes | ||
Battery protection for low voltage | Yes | ||
Batteries (default configuration) | 12V2AH*2 | 12V3.2AH*2 | 12V7AH*2 |
Detector circuit specification | |||
Number of circuit | 1-4 | 1-8 | 1-16 |
Line fault monitor for open circuit | Yes | ||
Line fault monitor for short circuit | Yes | ||
Line fault monitor for detector removal | Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor | ||
End of Line device | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) | ||
Detector continuity diodes | Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault) | ||
Call point resistor value | 470 to 680 Ω, 0.225 or 0.5 watt | ||
Maximum number of smoke/heat detectors per zone | 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts. | ||
Maximum number of manual call points per zone | No limit | ||
Sounder circuit specification | |||
Number of general circuits | 2 | ||
Number of each zone | 2 | ||
End of line resistor value | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) | ||
Line fault monitor for open circuit | Yes | ||
Line fault monitor for short circuit | Yes | ||
Outputs fused AT | 400mA | ||
Maximum number of bells @ 25mA of each zone | 16(These quantities are examples only. Divide 400 by the consumption of each sounder/bell in mA to calculate the maximum number.) | ||
Maximum number of bells @ 20mA of each zone | 20 | ||
Fuses | |||
Battery fuse | 1.5A F 20mm | 3A F 20mm | 5A F 20mm |
Sounder outputs | 500mA F 20mm |
|
|
Fire output | |||
Output type | Intended to drive external 24V relays | ||
Maximum current | 30mA(Relay resistance must be greater than 800Ω and relay must have “ back EMF” diode fitted). | ||
Connection block | |||
Largest acceptable conductor size | 2.5mm2 | ||
Smallest acceptable conductor size | 0.75mm2 | ||
Size and weight | |||
Dimensions(mm) | 395X388X124 | 395X502X124 | 362X565X124 |
Weight (without batteries) | 5kg | 7kg | 8kg |
Weight (with batteries) | 6.8kg | 9.6kg | 12.5kg |