Model | L6-GFM(G)-100 |
Cells Per Unit | 6 |
Voltage Per Unit | 12 |
Capacity | 100Ah@10 hr-rate to 1.80V per cell @25°C |
29Weight | 29kg |
Internal Resistance | Approx. 6mΩ |
Terminal | F1 / F2 |
Max. Discharge Current | 1500A(5s) |
Design Life | 15 years (floating charge) |
Maximum Charging Current | 25A |
Reference Capacity | C10 100.0AH C3 74.6AH C1 56.8AH |
Float Charging Voltage | 13.6 V~13.8 V @ 25°C Temperature Compensation: -20mV/°C/Cell |
Cycle Use Voltage | 14.4 V~14.9 V @ 25°C Temperature Compensation: -30mV/°C/Cell |
Operating Temperature Range | Discharge: -20°C~60°C Charge: 0°C~50°C Storage: -20°C~60°C |
Normal Operating Temperature Range | 25°C±5°C |
Self Discharge | Less than 3% at 25°C per month |
Container Material | A.B.S. |
Battery Rating | Warranty Period | |
AGM VRLA Batteries. 12V 1.2Ah, to 12V 28AH;6V 1.3Ah, to 6V 12Ah | 24 months from installation or 25 months from date of supply from company whichever is earlier | |
AGM VRLA Batteries. 12V 33Ah, to 12V 250AH;2V 100Ah, to 2V 3000Ah | 24 months from installation or 25 months from date of supply from company whichever is earlier | |
AGM VRLA Deep Cycle Batteries. 12V 65Ah, to 12V 250AH;2V 200Ah, to 2V 3000Ah | 24 months from installation or 25 months from date of supply from company whichever is earlier | |
GEL VRLA Batteries. 12V 33AH,to 12V 250AH | 36 months from installation or 37 months from date of supply from company whichever is earlier | |
GEL VRLA Batteries. 2V 200AH,to 2V 3000AH | 36 months from installation or 37 months from date of supply from company whichever is earlie | |
Lead Carbon Batteries.2V/12V 100AH,to 3000AH | 36 months from installation or 37 months from date of supply from company whichever is earlier | |
Tubular Gel Batteries. OPzV 2V 200AH,to 2V 3000AH | 36 months from installation or 37 months from date of supply from company whichever is earlier (Optional)60 months from installation or 61 months from date of supply from company whichever is earlier | |
Tubular Flooded Batteries. OPzS 2V 200AH,to 2V 3000AH | 36 months from installation or 37 months from date of supply from company whichever is earlier | |
NOTE: Extend warranty period is available. |
Payment Terms | T/T | EXW | 30% in advance for deposit payment, the balance payments will be paid before shipment. | ||||
FOB | |||||||
CFR/C&F | 30% in advance for deposit payment, the balance will be paid against copy of B/L | ||||||
CIF | |||||||
L/C | For the amount of one shipment above 50,000 usd, L/C at sight is acceptable. | ||||||
West Union | |||||||
Paypal | |||||||
Delivery Time | 7~25 days after receiving the payment or the deposit payment |
For product pricing, customiztion, or other inquiries
Contact Supplier
Customer Reviews total 0 items