Product Details
- Place of Origin:
- Guangdong, China
- Brand Name:
- Asenware
- Model Number:
- AW-CSD311
- Item:
- smoke detector
- Brand:
- Asenware
- Type:
- Conventional
- Model:
- AW-CSD311,YT102,CSH,CTD and so on
- Color:
- white or as customized
- OEM:
- acceptable
- Payment:
- T/T,WESTERN UNION,D/P and other
- Delivery time:
- 5-10 days
- Shipping way:
- as customized
- Voltage:
- 24v DC
- Supply Ability:
- 50000 Piece/Pieces per Month
- Packaging Details
- 10 pcs a paper box,10 boxes a carton
- Port
- shenzhen
Key words:smoke detector,2 wire smoke detector,conventional smoke detector,optical smoke detector,photoelectric smoke detector,wholesale smoke detector,fire alarm smoke detector,smoke sensor,addressable smoke detector,smoke detector supplier
The detectors are photo-electronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.
Two LEDs on each detector provide local 360° visible alarm indication. They flash every six
seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.
The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.
Heat detector and smoke & heat detector combine a photo electronic sensing chamber and a temperature heat detector.
Standby Current | ≤100μA @ 24 VDC |
Maximum Alarm Current | ≤55mA @ 24 VDC |
Operating Humidity Range | 10% to 93% Relative Humidity, Non-condensing |
Operating Temperature Range | 14°F to 120°F (-10°C to 49°C) |
Adjustable Sensitivity | 1-2.5%/FT |
Parameters
conventional smoke detector | ||
Executive standard | GB19880-250 | |
Operating voltage | 24V (pulse modulation) | |
Operating current | <300µA | |
Weight | 162g | |
Wiring method | nonpolar two-bus system | |
Operating enviroment | Indoor | |
temperature | -10°C~+50°C | |
Relative humidity | ≤95% |
Installation
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
INSTALLTHE DETECTOR BASE:
a. Open area smoke or heat detectors are intended for mounting on a ceiling or a wall in
accordance with the fire standard in your country.
b. Attach mounting base to ceiling or wall. The base of the detector can be mounted directly onto
an electrical junction box such as an octagonal (75mm, 90mm or 100mm), a round (75mm), or a
square (100mm) box without using any type of mechanical adapter.
c. Position all wires flat against terminals, and fasten the wires on the terminals, See Figure 1.
d. Terminals functions description:
Terminal 2: IN+( Zone Input+)
Terminal 5: IN- (Zone Input- )
Terminal 6: IN+( Zone Output+)
Terminal 5: IN- (Zone Output- )
Terminal 6: Remote Indicator+
Terminal 3: Remote Indicator-
5. Install the detector head
a. Align detector head alignment mark line with the base’s start alignment mark line as shown in
Figure 2
b. Push the detector head into the base while turning it clockwise to secure it in place.
c. Do not install the detector head until the area is thoroughly cleaned of construction debris, dusts,
etc.
d. After all detectors have been installed, apply power to the control panel.
e. Test the detector(s) as described in the TESTING section of this manual.
f. Notify the proper authorities that the system is in operation.
FIGURE1 Terminal
Install the detector head
a. Align detector head alignment mark line with the base’s start alignment mark line as shown in
Figure 2
b. Push the detector head into the base while turning it clockwise to secure it in place.
c. Do not install the detector head until the area is thoroughly cleaned of construction debris, dusts,
etc.
d. After all detectors have been installed, apply power to the control panel.
e. Test the detector(s) as described in the TESTING section of this manual.
f. Notify the proper authorities that the system is in operation.
Smoke Detector Diagrams
Shenzhen Asenware Test And Control Technology Co., Ltd was set up in 2006, our headquarters is in London of UK. Now Asenware is an international group company in BMS and NDT industries.
We are a technology oriented company that devotes to NDT(Non Destructive Test) and BMS(Building Management System) industries.
We have two factories : one factory is in Shenzhen city for BMS products, and the another is in Dandong city for NDT X-ray products.
In our BMS factory, we produce addressable and conventional fire alarm system, CCTV camera and DDC controller.
In our NDT X-ray factory, we produce portable and mobile NDT X-ray flaw detectors, X-ray analysis equipment and the dark room accessories.
We have an experienced R&D team to design special electric product for test and control usage.
We have been striving to provide customers with satifying service before, during and after sales.
Advantage of our factory and services
1) ISO certified factory with 8 years professional experience and alibity to accept and
fulfill ODM/OEM orders.
Includes:
The initial design service of appearance, structure and electronic parts
Mould opening
Sampling
Semi-products testing and supply
Mass Production for formal orders
We also can quote very quickly as customer provided samples for OEM service.
2) Flexible technicals adjusting and technical support as per customer" s special request.
3) Answer your enquiries, questions and emails in 24 hours
4) Direct control on material, testing, quality, leadtime etc.
Fire Alarm System Related Products
Smoke Detector Mass Product
Smoke Detector Certifications
Customer Reviews total 0 items