HFC-227ea is a clean extinguishing agent, which would completely vaporized in the air, and well insulated. Its total flooding mode is applicable to electric fire, liquid fire or fusible solid fire, solid surface fire, gas fire which gas supply is cut before extinguishing. And it is able to protect computer rooms, communication rooms,substation rooms, hi-tech device rooms, generator
rooms, gasoline storerooms, combustible chemical storerooms, libraries, data rooms, archives, treasuries, etc. We manufacture HFC-227ea system that is well structured, reliable, and widely applied to computer rooms, archives, program control exchange engine rooms , TV broadcast center, financial organizations and government departments.
1.20L HFC-227ea Cylinder specification:
Volume:20L;
Accessories: tank / valve/ internal siphon tube/pressure gauge/solenoid valve; Tank size:260*540*4mm (diameter*height*thickness);
Material: magamest steel;
Necking: M58X4;
Painting: red epoxy polysteter RAL3000/red coating polyster RAL3000,top green
Max protected area:max 800m²,max volume 3600m³; Operate: manual, auto and eletrical
2.20L HFC-227ea Cylinder detail pictures:
Check the all parts and test the cylinder before packing.Use bubble bag wrap the cylinder and accessories,packing into wooden case,good protect the goods.
Use wooden case to packing it,good protect products.
3.HFC-227EA Fire suppression system order instruction:
Before we make offer , we need your detailed information support to calculate the qty of Cylinder , weight of gas ,pipe size, nozzle ...
if the system you requested need design or not ?we design them free charges ,
We need following information to make design for your engineer projected
1>,What’s your protected subject :
Telecommunication Facilities?Computer operations?Control rooms?Rare book Libraries?..........
2>,Do you have room "s layout or drawing?If yes,pls send us your drawing.
if no please tell us below protection status:
A room size : length(m) X width(m) X height ( m)
B raise floor(can not greater than 30mm): _______(M ), or NO _____
C ceiling , height ____ (M) , or .no need consider
3>Do you need a pressure release device?
4> Storage cylinder must be placed in a separate room and towards the door opening direction?
5> . HFC-227ea system select
A , Dependable system one system protect a single room(no need flow check valve)
B. Muliti-hazard system (One system protect multiple rooms(use selection valve)_________
6>.Do you need fire alarm products ( control panel ,detectors , gas lamp ) yes no